Advertisement

Aquashield
Centurion
®
Installation and

Operating Instructions

Wall mounted models ASC50 & ASC70
DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ
THESE INSTRUCTIONS. Unit is supplied fully assembled.
Ultra violet radiation is harmful to skin and eyes.
DO NOT LOOK AT UV LAMP WHILE LAMP IS OPERATING.
Minimum operating pressure is 0kPa. Installation on a flooded suction is
recommended. Installation under vacuum is not advised, any damage to
persons or associated equipment will not be covered under this guarantee.
Maximum operating pressure for stainless steel UV chambers is 860kPa (125
psi). If this pressure can be exceeded or if operating close to this pressure fit
a suitable pressure limiting valve in the supply to the UV chamber.
WARNING: The UV Chamber operates under pressure. Under no
circumstances should the UV Chamber be disassembled unless the internal
pressure of the unit has been relieved. Failure to observe this warning will
expose persons to the possibility of personal injury and may result in damage
to the UV system or other property.
This unit is designed to treat water at ambient temperatures (5ºC to 45ºC).
Contact your dealer for details of UV systems suitable for hot water service.
The appliance is not intended for use by young children or infirm persons
without supervision.
Young children should be supervised to ensure they do not play with the appliance.
We recommend wearing clean, lint-free gloves any time the internal quartz
sleeve or lamp need to be handled.
If installing on Australian Municipal water sources, a dual check valve and back
flow prevention device must be fitted prior to any filters or the UV chamber.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
If any electrical supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
Please pass these instructions on to the operator of this equipment.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aquashield centurion ASC50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Davey aquashield centurion ASC50

  • Page 1: Operating Instructions

    Aquashield Centurion ® Installation and Operating Instructions Wall mounted models ASC50 & ASC70 DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ THESE INSTRUCTIONS. Unit is supplied fully assembled. Ultra violet radiation is harmful to skin and eyes. DO NOT LOOK AT UV LAMP WHILE LAMP IS OPERATING. Minimum operating pressure is 0kPa.
  • Page 2: Table Of Contents

    Contents Introduction .........................3 Model Selection ......................3 Installation ........................4 Preparing your system ..................4 Choosing a Site .....................4 Electrical Power Surge Protection ..............4 Power Connection ....................4 Mounting, Plumbing and Start-Up ...............5 LED Indicators ......................6 Alarms .........................6 Maintenance ........................7 Cleaning the quartz sleeve...................7 Changing the Filter Cartridge ................8 Replacing the UV lamp ..................9 Sediment Cartridge Filter Life ................9...
  • Page 3: Introduction

    Model Selection Davey Aquashield Centurion units are selected according to the maximum water or peak flow requirement. As it is not possible to overdose on UV treatment, the unit can be oversized for the flow.
  • Page 4: Installation

    Choosing a Site To protect your Davey Aquashield Centurion from the weather, make sure the site is water proof, frost free and has adequate ventilation. Choose a site with a structurally appropriate mounting position on the wall.
  • Page 5: Mounting, Plumbing And Start-Up

    Mounting, Plumbing and Start-up The unit has 25mm BSP plumbing connections. The inward side has a 25mm female connector and requires male plumbing. The outward side has a connector that requires either 25mm female plumbing OR 20mm male plumbing. – Use the mounting template to mark the position of holes required for mounting. Fix screws to the wall that will allow the Aquashield Centurion to be mounted using the key-holes in the back of the unit.
  • Page 6: Led Indicators

    Never use PVC pipe directly connected to unit. PVC pipe and fittings can be used after 90º metal elbows are connected to the inlet and outlet of the chamber eg. brass fittings. Larger diameter pipe may be used to minimise resistance to flow, but maximum flow rates should not be exceeded, as correct water treatment cannot be assured at higher flows.
  • Page 7: Maintenance

    Maintenance Cleaning the quartz sleeve – 3 monthly (or more often if used with hard water). If dirt is allowed to build up on the quartz sleeve it will impair the UV output. The quartz sleeve should be removed after one month and inspected for deposits. –...
  • Page 8: Changing The Filter Cartridge

    Changing the Filter Cartridge 1. Turn off the water flow to the cartridges at the valve, tank or tap. 2. Release the pressure by opening a tap downstream, or use the pressure relief valve that is available in the lid of the filter housings. 3.
  • Page 9: Replacing The Uv Lamp

    – Securely wrap the used lamp in the packaging and return it to your place of purchase for return to Davey Water Products and recycling. – If alarm sounds, turn power off for 5 minutes to allow internal reset of the power supply.
  • Page 10: Replacement Part Numbers

    During service DO NOT use lubricants or sealants of any type on the Steriflo o-ring. Keep the inside of the quartz sleeve dry and clean. After Sales Service For professional after sales service or repair, contact your Davey Dealer.
  • Page 12: Guarantee

    Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.