Output Wiring; Wireless Receiver - Bosch DS6R2 Installation And Operation Manual

Self-contained control panel
Table of Contents

Advertisement

DS6R2 | Installation and Operation Guide | 2.0 Installation
Keyswitch Wiring
Depending on programming settings, you can use a
keyswitch to arm or disarm the DS6R2:
If Program Address 29 is set to 1, the input operates
as a momentary keyswitch that can only arm the
system.
If Program Address 29 is set to 2, the input operates
as a maintained keyswitch that can arm and disarm
the system.
Refer to Figure 8.
Figure 8: Keyswitch Wiring
1
1 kΩ
B 485 A
+ 12 V -
RF
PO1
COM
PO2
NO
1- LED (not required for keyswitch)
2- Normally-open keyswitch
2.2.3.

Output Wiring

The DS6R2 has Form C (NO/C/NC) contacts rated
for 3 A at 28 VDC.
Two solid-state current sinks can be used for devices
with a current draw of up to 250 mA for each device.
Refer to Figure 9.
The operating voltage for attached relays cannot
exceed 15 VDC. Refer to Program Addresses 26 and 27
in Table 3 starting on page 11 for output options.
8
2
C
NC
Z1 COM Z2 Z3
COM
Z4
Z5
COM
Z6 INS KS
Figure 9: Output Wiring
+
-
2
+
-
1
B 485 A
+ 12 V -
RF
PO1
COM
PO2
NO
C
1- Device 1
2- Device 2
2.2.4.

Wireless Receiver

An RF3212 or RF3212E Receiver is required to use
key fobs and wireless devices with the system.
Refer to Figure 10.
Figure 10: Wireless Receiver Wiring
+
-
1
RF3212
1- 12 VDC power supply
2- +12 VDC
3- -12 VDC
4- Data
Bosch Security Systems, Inc. | 4/08 | F01U081960-01
NC
Z1 COM Z2 Z3
COM
Z4
Z5
COM
Z6 INS KS
2
3
4
B 485 A
+ 12 V -
RF

Advertisement

Table of Contents
loading

Table of Contents