Dismantling and fitting
8.19
Installing the gas outlet flange
Figure 52: Installing the gas outlet flange
1. If present: Insert the metal C-ring (57003) into the turbine casing (51000) and secure with
high-vacuum grease.
2. Fit swivel lifting eye (S) to the gas outlet flange (57002). Secure lifting gear to the swivel
lifting eye.
3. Install gas outlet flange in turbine casing (51000).
4. Measure radial clearance (R) (see chapter Radial clearances N and R).
© Copyright 2017 ABB. All rights reserved.
HZTL4032_EN
Page 97 / 120
Revision F