You can find further information in the comprehensive operating in- structions listed below. This manual is available on the supplied DVD or in the download area under "www.vega.com". Operating instructions VEGABAR 82 - HART and power pack: Document-ID 45029 Editing status of the quick setup guide: 2013-11-21 VEGABAR 82 • HART and accumulator pack...
During work on and with the device the required personal protective equipment must always be worn. Appropriate use The VEGABAR 82 is a pressure transmitter for process pressure and hydrostatic level measurement. Due to the integrated accumulator the instrument is particularly suitable as a portable measuring system or test sensor for special applications.
That is why we have introduced an environment management system with the goal of continuously improving company environmental pro- tection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfill this obligation by observing the environmental instructions in this manual: • Chapter "Packaging, transport and storage" • Chapter "Disposal" VEGABAR 82 • HART and accumulator pack...
Test certificate Pressure Transmitters (PDF) Go to www.vega.com, "VEGA Tools" and "Serial number search". Alternatively, you can access the data via your smartphone: • Download the smartphone app "VEGA Tools" from the "Apple App Store" or the "Google Play Store" • Scan the Data Matrix code on the type label of the instrument or VEGABAR 82 • HART and accumulator pack...
Page 6
2 Product description • Enter the serial number manually in the app VEGABAR 82 • HART and accumulator pack...
Ex-ia and Ex-d-ia version following functions: • Ventilation of the electronics housing • Atmospheric pressure compensation (with relative pressure meas- uring ranges) → Turn the housing so that the filter element points downward after the instrument is installed. This provides better protection against buildup. VEGABAR 82 • HART and accumulator pack...
Page 8
Double chamber housing plastic Double chamber housing Aluminium Filter element With the following instruments a blind plug is installed instead of the filter element: • Instruments in protection IP 66/IP 68 (1 bar) - ventilation via capil- laries in non-detachable cable • Instruments with absolute pressure VEGABAR 82 • HART and accumulator pack...
Fig. 3: Position of the power supply and electronics compartment Supply room (accumulator) 2 Electronics compartment Electronics compartment 4...20mA 6 7 8 Fig. 4: Electronics compartment, double chamber housing Internal connection to the connection compartment Contact pins for the display and adjustment module VEGABAR 82 • HART and accumulator pack...
Page 10
(accumulator life time) After pressing the key or changing the mode the yellow LED shows the accumulator status for approximately 10 s as follows: • LED lights = accumulator is full • LED flashes = accumulator should be charged • LED off = accumulator is empty VEGABAR 82 • HART and accumulator pack...
3. Screw housing cover with inspection window tightly back on Removal is carried out in reverse order. The display and adjustment module is powered by the sensor, an ad- ditional connection is not necessary. Fig. 6: Installing the display and adjustment module in the electronics compart- ment of the single chamber housing VEGABAR 82 • HART and accumulator pack...
Carry out the following steps in the below sequence. You can find "Extended adjustment" in the next sub-chapter. Presettings 1. Measurement loop name In the first menu item you assign a suitable measurement loop name. Permitted are names with max. 19 characters. 2. Application In this menu item, you activate/deactivate the slave for the electronic differential pressure and select the application. The application com- prises process pressure and level measurement. VEGABAR 82 • HART and accumulator pack...
In this menu item you carry out the min. adjustment for level Enter the percentage value and the corresponding value for the min. level. The quick setup is finished. Parameter adjustment - Extended adjustment For technically demanding measuring points, you can carry out extended settings in "Extended adjustment". VEGABAR 82 • HART and accumulator pack...
Page 14
The submenu points described below. Setup Menu item Measurement loop name Application Units Unit of measurement Temperature unit Position correction Adjustment Min. adjustment Max. adjustment Damping Integration time Linearization Linearization type Scaling Scaling 1 VEGABAR 82 • HART and accumulator pack...
Page 15
Sensor status Status signals - Function control Status signals - Out of specification Status signals - Maintenance Status signals - Failure Peak value indicator Pressure Temperature Simulation Additional adjustments Menu item Date/Time Copy instrument settings Special parameters HART mode VEGABAR 82 • HART and accumulator pack...