McCrometer Ultra Mag Installation, Operation And Maintenance Manual

Electromagnetic flowmeters

Advertisement

ELECTROMAGNETIC
FLOWMETERS
INSTALLATION, OPERATION AND
MAINTENANCE MANUAL
30119-03 Rev. 5.2
December, 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Mag and is the answer not in the manual?

Questions and answers

Summary of Contents for McCrometer Ultra Mag

  • Page 1 ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 5.2 December, 2014...
  • Page 2: Table Of Contents

    5 RETURNING A UNIT FOR REPAIR ................................10 WARRANTY ...........................................11 Copyright © 1997-2015 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published technical data and instructions are subject to change without notice. Contact your McCrometer representative for current technical data and instructions.
  • Page 3: Introduction

    When uncrating the Ultra Mag, any damage due to rough or improper handling should be reported to the transportation firm and McCrometer. If for any reason it is determined that the unit or parts of the unit should be returned to the factory, please contact McCrometer for clearance prior to shipment. Each unit must be properly crated to prevent any further damage.
  • Page 4: Parts List With Remote Mount Converter

    1.3. Parts List With Remote Mount Converter Optional on 4” - 12” Figure 1: 2”- 3” Model Figure 2: 4” - 12” Model Figure 3: 14” And Larger Model PART NUMBER DESCRIPTION 880003032 AC Converter (Dual 4-20mA Output) 880003042 DC Converter (Dual 4-20mA Output) 880003043 AC Converter w/ Modbus RS485 Communications Protocol 1-1701-11...
  • Page 5: Serial Numbers

    Consult an electrician experienced with instrumentation installations to determine if electrical interference is present. For further information on installation environments and sensor grounding, please contact McCrometer Technical Support. 2.1.2 Lines With Cathodic Protection On meters installed on a line with cathodic protection it may be necessary to insulate the meter from the line.
  • Page 6: Meter Mounted Converter Location

    2.1.7 Converter/transmitter Connections Connections to the sensor must be made with cable supplied by McCrometer specifically for that purpose. Do not substitute the supplied cable with other types of cable, even for short runs. For repairs or added lengths of cable, the entire cable between the sensor and the converter must be replaced.
  • Page 7: Sensor Orientation

    2. SENSOR INSTALLATION - Cont. 2.2.3 Sensor Orientation The following installation recommendations should be followed (see Figure 2 for installation diagrams): A. In horizontal pipe runs, the meter should be installed so that the junction box is vertical insuring the electrodes are positioned to prevent coating by sediments or loss of electrode contact due to air bubbles.
  • Page 8: Quick Connect Cable Ends (Optional)

    3. QUICK CONNECT CABLE ENDS (OPTIONAL) Quick Connect cable end fittings are optional. If selected at the time of order, follow the instructions below: 1. Remove the protective caps from both the receiving ports and the cable ends. 2. Insert the cable end into the port until fully seated, then turn the knurled collar on the cable to the right until the cable is tight.
  • Page 9: Dimensions

    4. DIMENSIONS End View Side View Figure 12: 2" and 3" Models Body Style Side View End View Figure 13: 4" to 12" Models Body Style Side View End View **Grounding Rings are 0.125" thick. Figure 14: 14+" Models Body Style...
  • Page 10 4. DIMENSIONS - Cont. Meter Body Dimenesions And Weights †Estimated DIMENSIONS Flow Ranges GPM Shipping (Lay Lengths) Pipe Size Meter Standard Weight (lbs.) (Nominal) Pipe ID .2 to 32 FPS Min - Max UM06 UM08 UM06 UM08 UM06 UM08 2" 2.117 2 - 340 11.00...
  • Page 11: Specifications

    Accuracy Tests: 3-point wet flow calibration of every complete flow tube with its signal converter. If desired, the tests can be witnessed by the customer. The McCrometer test facilities are traceable to the National Institute of Standards & Technology. The test facility uncertainty relative to flow is ±.15% Repeatability: ±0.05% or ±0.0008ft/s (±0.25mm/s), whichever is greater...
  • Page 12: Returning A Unit For Repair

    Prior to calling for a return authorization number, determine the model number, serial number, and reason for return. • Call the McCrometer Customer Service Department and ask for a Return Authorization (RA) number. • Ship the meter in the original packaging, if possible. Do not ship manuals, power cords, or other parts with your unit unless required for repair.
  • Page 13: Warranty

    McCrometer, free of charge, FOB the factory in Hemet, California, within a period of two (2) years from the date of delivery.
  • Page 14: Of Mccrometer. Any Published Technical Data And Instructions Are Subject To Change Without Notice. Contact Your

    Printed In The U.S.A. Lit. # 30119-03 Rev. 5.2/12-14 Copyright © 1997-2015 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published technical data and instructions are subject to change without notice. Contact your...