Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, and Intimidator Spot 375Z IRC are registered trademarks or trademarks of Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
Keep this User Manual for future use. If you sell the product to someone else, be sure that they also receive this document. Page 2 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Handles Infrared Sensor Safety Menu Power Power Fuse Indicator Display Loop Buttons Holder In/Out Product Dimensions 18.3 in 466 mm 12.7 in 8.6 in 322 mm 220 mm Intimidator Spot 375Z IRC User Manual Rev. 3 Page 3 of 21...
3. Setup AC Power The Intimidator Spot 375Z IRC has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The Intimidator Spot 375Z IRC may be mounted in any position; however, make sure adequate ventilation is provided around the product. Rigging • Before deciding on a location, always make sure there is easy access to the product for maintenance and programming purposes.
_ _ _ _ _ _ _ Displays the current running mode Sys Info DMX Address _ _ _ Displays the current DMX address Temperature _ _ _ Displays current temperature in °C Page 6 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Operation Configuration (DMX) The Intimidator Spot 375Z IRC works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website http://www.chauvetlighting.com/downloads/ DMX_Primer_rev05_WO.pdf. Starting Address When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses.
063 Gobo indexing 145 Rotation, slow to fast Gobo Rotation 149 Stop 231 Reverse rotation, slow to fast 255 Bounce, slow to fast Page 8 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Page 11
127 Gobo wheel reset 135 No function 143 Prism reset 151 Focus and zoom reset 159 All reset 255 No function Intimidator Spot 375Z IRC User Manual Rev. 3 Page 9 of 21...
063 Yellow White 189 Color indexing 221 Color cycling rainbow, slow to fast 223 Stop 255 Reverse color cycling rainbow, slow to fast Page 10 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Page 13
076 Strobe, slow to fast Shutter 145 Pulse strobe, slow to fast 215 Random strobe, slow to fast 255 Open Zoom 255 Narrow to wide Intimidator Spot 375Z IRC User Manual Rev. 3 Page 11 of 21...
Press <ENTER>. Use <UP> or <DOWN> to select Sound. Press <ENTER>. Sound Sensitivity To change the sound sensitivity on the Intimidator Spot 375Z IRC, follow the instructions below: Press <MENU>. Use <UP> or <DOWN> to select Setup. Press <ENTER>. Use <UP> or <DOWN> to select Sensitivity.
Use <UP> or <DOWN> to select from 540 (540°), 360 (360°), or 180 (180°). Press <ENTER>. Tilt Angle To set the tilt angle range on the Intimidator Spot 375Z IRC, follow the instructions below: Press <MENU>. Use <UP> or <DOWN> to select Setup.
Press <ENTER>. Use <UP> or <DOWN> to select Reset. Press <ENTER>. Factory Reset To restore the Intimidator Spot 375Z IRC to factory default settings, follow the instructions below: Press <MENU>. Use <UP> or <DOWN> to select Setup. Press <ENTER>. Use <UP> or <DOWN> to select Factory Set.
Operation IRC-6 Infrared Remote Control The Intimidator Spot 375Z IRC is compatible with the IRC-6 infrared remote control from Chauvet. To set the Intimidator Spot 375Z IRC to IR mode, follow the instructions below: Press <MENU>. Use <UP> or <DOWN> to select Run Mode.
The Master/Slave mode allows a single Intimidator Spot 375Z IRC product (the “master”) to control the actions of one or more Intimidator Spot 375Z IRC products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in either Stand-Alone mode or with the IRC-6, while the slave products will be set to operate in Slave mode.
Move the holder slightly from the side to side if needed to get it to sit properly. If correctly installed, the bottom of the holder will be flush with the gobo wheel. 11. Replace the cover of the Intimidator Spot 375Z IRC and secure with the 4 screws. Intimidator Spot 375Z IRC User Manual Rev. 3...
Softly drag any dirt or grime to the outside of the transparent surface. Gently polish the transparent surfaces until they are free of haze and lint. Always dry the transparent surfaces carefully after cleaning them. Page 18 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended. Chauvet reserves the right to use its own discretion to repair or replace returned product(s). Page 20 of 21 Intimidator Spot 375Z IRC User Manual Rev. 3...
Outside the U.S., United Kingdom, Ireland, Mexico or Benelux, contact the dealer of record. Follow the instructions to request support or to return a product. Visit our website for contact details. Intimidator Spot 375Z IRC User Manual Rev. 3 Page 21 of 21...
Need help?
Do you have a question about the intimidator SPOT 375Z IRC and is the answer not in the manual?
Questions and answers