Summary of Contents for FMC Technologies AccuLoad II
Page 1
® ® ® ® ® AccuLoad II - SEQ Programming Workbook Issue/Rev. 0.6 (5/96) Bulletin AB06030 This worksheet applies to AccuLoad II operating with Security Access Code: SEQ-00 and above firmware. (Refer to Operator Ref- Company Name: erence Manual MN06054L for complete program entry descriptions.)
Table of Contents System Directories..............................2 System Configuration Directory........................2 System General Purpose Directory ......................8 System Flow Control Directory....................... 11 System Volume Accuracy Directory ....................... 14 System Temperature & Density Directory ....................17 System Pressure Directory ........................18 System Read Only Directory........................19 System Communication Directory ......................
Page 3
Directories System Product 1 Product 2 Product 3 Product 4 Blend Recipe Configuration General Purpose General Purpose General Purpose General Purpose Recipe 1 General Purpose Flow Control Flow Control Flow Control Flow Control through Flow Control Volume Accuracy Volume Accuracy Volume Accuracy Volume Accuracy Recipe 24...
Program Program Code Function Code Description Entry Code System Directories System Configuration Directory Number of Products Enter: "1" One (1) Product "2" Two (2) Products "3" Three (3) Products "4" Four (4) Products Number of Additive Enter: "0" No Additive Injectors Injectors "1"...
Page 6
__ __ Note: 1. This code is only available for use if the Quad OPV option has been purchased with the AccuLoad II. The terminals listed for this code are located on the Quad OPV board. 2. When using a Smart Additive Subsystem, options 02 through 08 (Additive Relays) are not available for selection.
Page 9
Note: Entering the above number will program the AccuLoad II to a typical Input and Output configuration for the number of products selected. Refer to manual MN06054L for input & output assignments when using this method of configuring the AccuLoad II - SEQ.
Program Program Code Function Code Description Entry Code System General Purpose Directory System Alarm Check/Reset Read only, Press E to clear None Available Alarms AC: Additive Communications** L5: Additive 5 Pulse** A2: Print Cover Open L6: Additive 6 Pulse** A4: Print Cover Open L7: Additive 7 Pulse** B2: Buffer Overflow M1: Too Many Pulses Additive 1**...
Page 11
Program Program Code Function Code Description Entry Code Product 1 Alarm Check/Reset Read only, Press E to clear None Available Alarms BH: Blend High HP: High Pressure BL: Blend Low HT: High Temperature BP: Back Pressure LD: Low Density BV: Block Valve Fault LF: Low Flow HD: High Density LP: Low Pressure...
Page 12
"0" English Initialization "1" Not Used "2" Spanish Note: Entry "1" is reserved for future use and is not allowed by the AccuLoad II. Note: This code applies to SEQ-09 and above firmware. Ready/Run Mode Enter: The number of the alarm that is to...
‘ENTER’ key. The display can be changed using the character set resident in the AccuLoad II. (See Appendix for entry numbers and to record translation.) Note: This code applies to SEQ-09 and above firmware.
Page 14
Program Program Code Function Code Description Entry Code Zero Flow Timer Enter: Two (2) digits in seconds (e.g., 15) "00" disables this option __ __ Overrun Alarm Limit Enter: Two (2) digits in whole units (e.g., 15) "00" disables the alarm __ __ Start Delay After Stop Enter: Three (3) digits in whole...
Page 15
Program Program Code Function Code Description Entry Code Block Valve Enter: "0" Valve off SP & ET Position "1" Valve on SP, off ET "2" Valve off SP, on ET "3" Valve on SP & ET Note: ET = End of Transaction and SP = Stop is Pressed 284-299 Unassigned at Present 284-299...
Program Program Code Function Code Description Entry Code System Volume Accuracy Directory Transaction Control Enter: "0" Local Tray Switch "1" Print Key "2" Remote "3" Master Reset Maximum Preset Enter: Five (5) digits in whole units Volume (e.g., up to 99,999 units) "00000"...
Page 17
Program Program Code Function Code Description Entry Code Dual Pulse Error Enter: Three (3) digits indicating Count the number of error counts from the Dual Pulse Comparator prior to alarming. (e.g., 050) __ __ __ Note: "000" disables the error counting. Dual Pulse Error Enter: "0"...
Page 18
Program Program Code Function Code Description Entry Code Pulse #2 Output Enter: Four (4) digits defining Resolution the pulse output resolution (units/pulse) in tenth units, "0000" Disables this feature (e.g., 010.0) __ __ __ . __ Note: Input pulses must be 2.5 times greater than the output pulses (e.g., 100 output pulses/unit volume requires at least 250 input pulses/unit volume).
Enter: "0" Density Input Temperature Input "1" Temperature Input Note: If Temperature is selected AccuLoad II will ignore the RTD channel. To accept readings from the RTD channel this entry must be selected for density input. Density Units Enter: "0" No Densitometer Installed "1"...
Program Program Code Function Code Description Entry Code Minimum Density Enter: Five (5) digits. For OR Minimum minimum density at 4 mA in Temperature tenth units (e.g., 0100.0). as selected in For minimum Temperature at 4 mA the code 444 first digit indicates the polarity.
Program Program Code Function Code Description Entry Code Maximum Pressure Enter: Four (4) digits in tenth Units units for maximum pressure at 20 mA. (e.g., 4500 = 450.0) Units dependent on selection in code 541. "0000" indicates no pressure transducer installed. __ __ __ . __ 544-599 Unassigned at Present 544-599...
Page 22
Program Program Code Function Code Description Entry Code EIA-232 Baud Rate Enter: "0" for 110 Baud "1" for 150 Baud "2" for 300 Baud "3" for 600 Baud "4" for 1200 Baud "5" for 2400 Baud "6" for 3600 Baud "7"...
Page 23
Program Program Code Function Code Description Entry Code Printer Output Enter: Up to twenty (20) characters Message #1 for printer message (e.g., Smith Meter Inc.)____________________ Printer Output Enter: Up to twenty (20) characters Message #2 for printer message (e.g., P. O. Box 10428) ____________________ Printer Output Enter:...
Page 24
Program Program Code Function Code Description Entry Code Communication Link Enter: "0" for No Program Code Values Programming "1" for Program Values Only "2" for Program and Weights and Measures Values "3" for Alarm Reset Only Communications Enter: Three (3) digits in seconds Time-out that communication polling may be absent (e.g., 060)
Page 25
"1" for Local SP Alarm "2" for Program SP Alarm Shared Printer Out Enter: Two (2) digits in minutes Timer of time that the AccuLoad II will wait before Alarming. __ __ EIA-232 Printer Enter: "0" No 232 Security Security "1"...
Page 26
Program Program Code Function Code Description Entry Code Select Volumes to Enter: Five (5) digit number indicating Print the totals that will be printed on the Product Receipt Ticket. 1st digit - Raw Totals 2nd digit - Gross Totals 3rd digit - Gross at Standard Temperature Totals 4th digit - Net Totals 5th digit - Mass Totals...
Page 27
Program Program Code Function Code Description Entry Code Select Load Averages Enter: Two (2) digit number indicating to Print the load averages that will be printed on the Product Receipt Ticket. 1st digit - Load Average Temperature 2nd digit - Load Average Density A zero (0) in the digit indicates the load average will not be printed, a one (1) indicates the load average will...
Page 28
Program Program Code Function Code Description Entry Code Define Delivery Enter: Eight digits in the form of Report three digits for the current line (000), two digits for the column number that the data will start at (00), and the item that will be printed (000) on the delivery report.
Program Program Code Function Code Description Entry Code 767-779 Unassigned at Present 767-779 Number of Prompts Enter: One (1) digit between 0 and 5 representing the number of prompts used in the Standby Mode (e.g., 4) "0" Disables prompts in the Standby Mode Print Transaction Enter: Three (3) digit Transaction...
Page 30
Program Program Code Function Code Description Entry Code Permissive #1 Enter: "0" No Permissive 1 "1" Permissive 1 Transaction Start Only "2" Permissive 1 Continuously "3" Start Permissive 1 "4" Batch Permissive 1 "5" Remote Start Note: Option 5 requires hardware jumpers (see Installation Manual MN06037). Permissive #1 Enter: Up to twenty (20) characters...
Page 31
Program Program Code Function Code Description Entry Code Additive Injector #1 Enter: "0" No Injector 1 Feedback Feedback "1" Injector 1 Feedback/Control "2" INJ1 Feedback Only Additive Injector #1 Enter: Six (6) digits defining Volume the volume of additive to be injected for each Additive Injector cycle (e.g., 001.000) __ __ __ .
Page 32
Program Program Code Function Code Description Entry Code Additive Injector #7 Enter: "0" No Injector 3 Feedback Feedback "1" Injector 3 Feedback/Control "2" Injector 3 Feedback Only Additive Injector #7 Enter: Six (6) digits defining Volume the volume of additive to be injected for each Additive Injector cycle (e.g., 001.000) __ __ __ .
Program Program Code Function Code Description Entry Code Additive Feedback Enter: "0" Additive Feedback Alarm with Alarm Shut-down. "1" Additive Feedback Alarm Message at the End of the Batch with No Shut-down. Note: This code applies to SEQ-05 and above firmware. Additive Totals Enter: "0"...
Page 34
Program Code Function Code Description Entry Code Diagnostic Firmware Version None Diagnostic AccuLoad II Model Number Read Only Diagnostic ACM Model Number Read Only Diagnostic System Messages Diagnostic Calibration Event Counter None Note: This code applies to SEQ-14 and above firmware.
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Product Directories Product General Purpose Directory 101-139 Unassigned at Present Protection of Program Enter: "0" for Weights and Measures Mode Codes 180 - 189 "1" for Program Mode Product Selection Enter: "0"...
(e.g., 0400) _____ _____ _____ ______ Note: If the flow rate is set at zero the AccuLoad II will ignore codes 344 through 348. Meter Factor #2 Enter: Five (5) digits as one (1) whole number followed by four (4) decimals (e.g., 1.0040)
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Meter Factor Enter: Four (4) digits representing Reference the temperature that the percent Temperature meter factor variation was determined, Three (3) whole units and one (1) decimal in degrees (i.e., 120.1) _____._ _____._ _____._ _____._ 351-389 Unassigned at Present Master Meter Factor...
Page 38
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Low Temperature Enter: Four (4) digits. The Alarm first digit indicates polarity. First digit "0" = Positive First digit "1" = Negative The last three (3) digits indicate temperature in whole degrees.
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Pressure Directory Minimum Back Enter: Four (4) digits to select Pressure Flow the minimum flow rate allowed Rate Setting during back pressure operation in whole units per minute. (e.g., 0100) "0000"...
Page 40
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Low Vapor (P1) Enter: Four (4) digits indicating Pressure the low vapor pressure in PSIA, Bars or kg/cm in tenths of pressure units, (e.g., 006.0). Pressure units are dependent on entry made in code 541 of Systems Directory.
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Maintenance Pressure Enter: Four (4) digit maintenance pressure to be used when a pressure transducer is not installed, in tenths of units (e.g., 150.0) Pressure units dependent on selection made in code 541 of the Systems Directory.
Program Code Function Code Description Prod 1 Prod 2 Prod 3 Prod 4 Protection of Program Enter: "0" for Weights and Measures Mode Codes 780-789 "1" for Program Mode 741-799 Unassigned at Present Inputs & Outputs Directory 801-839 Unassigned at Present Protection of Program Enter: "0"...
Program Program Code Function Code Description Entry Code Blend Recipe Directories Blend Recipe # __ Directory __00 __00 __01 Blend Recipe Enter: "0" Recipe Not Used __01 "1" Manual Recipe "2" Auto Recipe __02 Blend Recipe Name Enter: Up to nine (9) characters for __02 meter or product identifier.
Page 44
Program Program Code Function Code Description Entry Code __05 Product using Enter: Four (4) digit number indicating __05 Injector #3 the products this injector is used with. 1st digit - Product 1 2nd digit - Product 2 3rd digit - Product 3 4th digit - Product 4 A zero (0) in the digit indicates the injector will not be used...
Page 45
Program Program Code Function Code Description Entry Code __08 Product using Enter: Four (4) digit number indicating __08 Injector #6 the products this injector is used with. 1st digit - Product 1 2nd digit - Product 2 3rd digit - Product 3 4th digit - Product 4 A zero (0) in the digit indicates the injector will not be used...
Page 46
Program Program Code Function Code Description Entry Code __15 HM Classification Enter: "1" Product 1 __15 "2" Product 2 "3" Product 3 "4" Product 4 __16 Minimum Preset To be read only __16 __17-__39 Unassigned at Present __17-__39 __40 Protection of Program Enter: "0"...
Page 47
Program Program Code Function Code Description Entry Code __49 Fourth Component Enter: "0" Not Used __49 Number to Deliver "1" Product 1 "2" Product 2 "3" Product 3 "4" Product 4 __50 Fourth Component Enter: Four (4) digits in tenth __50 Percentage of a percent (e.g., 050.0).
Page 54
Appendix I SEQ Display Customization Entry Table Entry Entry Description Translation Output Number Length *001 Alarm - See Manager *002 Alarm Press "CLEAR" *003 Alarm Press "PRINT" *004 Alarm - Remove Ticket ** Remove Ticket ** Please Wait Report Pending to Print No Local Start Allowed Meter Position Not Used Press Clear to Continue.
Page 55
Appendix I Entry Entry Description Translation Output Number Length **031 Inj2 Trans **032 Inj3 Trans **033 Inj4 Trans **034 Inj5 Trans **035 Inj6 Trans **036 Inj7 Trans Inj1 Total Inj2 Total Inj3 Total Inj4 Total Inj5 Total Inj6 Total Inj7 Total Density Total **046...
Page 56
Appendix I Entry Entry Description Translation Output Number Length Temp Gross 070, 071, 072 Preset batch volume exceeds 3 * 24 the maximum permitted. 073, 074, 075 Preset batch volume is below 3 * 24 the minimum required. 076, 077, 078 The preset volume will cause 3 * 24 the max transaction volume...
Page 58
Appendix I Note: * An entry number flagged with an asterisk (*), designates that the entry description should have a leading space in the message. This will allow for display concatenation without running words together. Note: ** An entry number flagged with two asterisks (**), designates that the entry description should have a trailing space in the message. This will allow for display concatenation without running words together.
Page 59
Appendix II Ready/Run Mode Clearable Alarms Entry Alarm 0 = Clearable 1 = Not Clearable CM: Communications TK: Ticket TP: Temperature Probe OA: Overrun PT: Pulse Transmission VF: Valve Fault PR: Pressure Transducer PC: Pulse Collision PS: Pulse Security DP: Down Pulse DR: Density Transducer TT: Temperature Transducer SP: Set at entry 751 (Shared Printer)
Page 60
Appendix II Entry Alarm 0 = Clearable 1 = Not Clearable A4: Set at entry 755 (485 Cover Open) D4: Set at entry 755 (485 Deselected) B4: Set at entry 755 (485 Buffer OverFlow) P4: Set at entry 755 (485 Communications) E4: Set at entry 755 (485 General Error) I4: Set at entry 755 (485 No Response) CL: Clean Line...
Page 61
Appendix II Entry Alarm 0 = Clearable 1 = Not Clearable Note: Applies to SEQ-13 and above firmware. R7: Additive 7 Frequency Note: Applies to SEQ-13 and above firmware. L1: Additive 1 Pulse Note: Applies to SEQ-13 and above firmware. L2: Additive 2 Pulse Note: Applies to SEQ-13 and above firmware.
Page 62
Appendix II Entry Alarm 0 = Clearable 1 = Not Clearable Note: Applies to SEQ-13 and above firmware. K1: Low Additive 1 Note: Applies to SEQ-13 and above firmware. K2: Low Additive 2 Note: Applies to SEQ-13 and above firmware. K3: Low Additive 3 Note: Applies to SEQ-13 and above firmware.
Need help?
Do you have a question about the AccuLoad II and is the answer not in the manual?
Questions and answers