Vanderbilt SPCK520 User Manual
Vanderbilt SPCK520 User Manual

Vanderbilt SPCK520 User Manual

Hide thumbs Also See for SPCK520:

Advertisement

SPCK520/521
Compact Keypad
User Guide
3.6
I-200004-1
01.10.2015
Vanderbilt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPCK520 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vanderbilt SPCK520

  • Page 1 SPCK520/521 Compact Keypad User Guide Vanderbilt I-200004-1 01.10.2015...
  • Page 2 Copyright Copyright Technical specifications and availability subject to change without notice. © Copyright Vanderbilt We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to...
  • Page 3: Table Of Contents

    User programming via the keypad ..............28 User Menus ......................28 8.1.1 SYSTEM STATUS ................29 8.1.2 ISOLATE ..................... 29 8.1.3 INHIBIT ....................30 8.1.4 SET DATE/TIME ................. 30 8.1.5 TEST ....................31 8.1.5.1 BELL TEST ..................31 Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 4 GRANT ACCESS ................42 8.1.15 REPORT TO ENG ................43 8.1.16 ALARM LOG ..................43 Appendix ......................44 User rights ......................44 Zone chart ......................46 User PINs ......................47 Prioritization of display messages ..............47 Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 5: Security

    Maintenance work must only be carried out by trained specialists.  Danger of electrical shock while cleaning the device Do not use liquid cleaners or sprays that contain alcohol, spirit or ammonia.  Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 6: Meaning Of Written Warning Notices

    Possible danger of death or severe bodily harm. CAUTION Danger of minor bodily injury or property damage IMPORTANT Danger of malfunctions Meaning of hazard symbols WARNING Warning of hazard area WARNING Warning of dangerous electrical voltage Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 7: Directives And Standards

    2 Directives and standards EU directives The SPCK520 Compact Keypad and the SPCK Compact Keypad with Card Reader comply with the requirements of the European Directives that are applicable for each of them. The EU declaration of conformity is available to the responsible agencies at: http://pcd.vanderbiltindustries.com/doc/SPC...
  • Page 8: Introduction

    Introduction EU directives 3 Introduction The SPCK520 and SPCK521 Compact Keypads are wall-mounted devices that allow users and engineers to interact with the SPC intruder alarm system. Users can perform operational procedures (set/unset) on the system, and  control the system on a day-to-day basis. Users can also configure the system through the programming menus.
  • Page 9 Portable ACE Fob to within 1 cm of this area. OK key Confirm display or input Multi-functional navigation keys Navigation through menus and to scroll through alert messages. (See Display Message Prioritization below) Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 10: Led Description

    The LED indications for information, area status, alarm and fault are deactivated in the idle state of the keypad. A valid user PIN must be entered. The PIN is configurable if the power indication can be seen in the idle state. Vanderbilt Compact Keypad User Manual I-200004-1...
  • Page 11: Viewing Mode Description

    Depending on configuration, emergency keys are displayed. A simultaneous pressing of the keys activates an emergency call. Panic Alarm Fire alarm Medical Alarm The activated process depends on the system configuration. Please ask the installer for details. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 12 Function keys in idle state Direct Settings Depending on configuration, the direct set option is displayed. A forced set / part set without PIN is possible of the area the keypad is assigned to. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 13: Keypad Character Map

    Alphabetic characters are selected by applying the appropriate number of key presses. To switch between upper and lower case characters, press the hash (#) key. To enter a numeric digit, hold down the appropriate key for 2 seconds. Vanderbilt Compact Keypad User Manual I-200004-1...
  • Page 14: Login

    If the keypad has been fitted with a proximity device receiver, users should present the fob to within 1 cm of the card reader receiving area. The card reader receiving area is next to the alphanumeric keypad and is indicated by the following icon: Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 15: Login With Pin And Card

    The pace has to be presented first. If a code is entered first, the message “present pace” will be displayed. After presenting the pace, due to the forced order, the PIN has to be entered again. Vanderbilt Compact Keypad User Manual I-200004-1...
  • Page 16: Single Area View

    If, for example, there is an open zone, the setting symbol will be displayed with an information symbol: Press the softkey below the setting symbol.   In the next screen, the information will be shown. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 17: Resetting A Fault

    RF FOB LOW BATT Subsequent setting of the system using the fob will be prevented until the alert is cleared. Resetting a fault If there is any fault, this will be displayed after login:  Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 18: Restoring An Alarm

    If the fault can be restored, press the softkey below the symbol   The fault is restored.  Ready will be shown on the display. Restoring an alarm If there is any alarm, the alarm will be displayed after login. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 19 Please contact your installer if symbol is still indicated after closing according zone (e.g. window). Alarm can be restored. If the alarm can be restored, press the softkey below the symbol   The alarm is restored. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 20: Multi Area View

    4. Press the relevant softkey to change the state. To change the state of all areas: 1. Scroll using the▼ key to ALL MY AREAS. (in area group view) 2. Press the relevant softkey to change the state. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 21: Clearing An Alarm

    2. Press the relevant softkey. 3. Scroll using the ▲ ▼ keys until the required area is visible. 4. Press the softkey below the blinking alarm symbol.  In the next screen, the alarm(s) will be listed. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 22: Resetting A Fault

    In this case it does not matter which area group / area is selected. 1. Scroll using the ▲ ▼ keys until the required area group is visible. 2. Press OK. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 23: Setting Not Possible

     The fault is cleared.  Ready will be shown on the display. Setting not possible If, for example, there is an open zone, the setting symbol will be displayed with an information symbol: Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 24 The Entry – Exit zone is open. Zone will not prevent setting process. Zone has to be closed at the end of the exit timer. If the zone is still open, setting will fail. Vanderbilt Compact Keypad User Manual I-200004-1...
  • Page 25: Automatic Calendar Setting

    When the timer displays next to an area, 3 timer symbols display above the soft keys: Symbol Function To view the number of minutes left before the area sets: Press the soft key below the Timer Info symbol. Example: TIME TO FULLSET 9 MIN 3 SEC Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 26: Time Locked

    Timer Info and Timer Delay symbols will display as described in the section Automatic Calendar Setting [➙ 25]. It is not possible to cancel setting for an ATM or Vault area. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 27 Within the interlock group, only one area can be unset at a time. The padlock symbol displays next to the other areas in the group to indicate that they cannot be unset. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 28: User Programming Via The Keypad

    SMS control operations which they can perform remotely and a selection of SMS events which they can receive. An SMS ID is assigned to a user. CHANGE PIN Allows users to change their user PIN. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 29: System Status

    ZONE Select the required zone and toggle the setting from NOT ISOLATED to ISOLATED. SYSTEM Isolate the desired system alert. XBUS Isolate the desired alert from EXPANDERS or KEYPADS: XBUS COMMS LOST  Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 30: Inhibit

    The date and time can be manually entered on the system. The time and date information is displayed on the keypad and browser and is used on time-related programming features. 1. Scroll to SET DATE/TIME and press SELECT. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 31: Test

    If a zone activation does not get acknowledged by the system, check the wiring of the sensor and/or replace with another sensor if necessary. NOTICE All zones can be included in an Engineer walk test. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 32: Wpa Test

     If the test fails, the message ‘SEISMIC FAIL’ is displayed. If the “i” or VIEW key is pressed, a list of the failed zones is displayed which can be scrolled through.  If the test succeeds, ‘SEISMIC OK’ is displayed. See also Seismic Sensor Testing. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 33: Visual Indicators

    8.1.9.1 To add users to the system: 1. Scroll to USERS > ADD.  Select a user ID from the available IDs on the system and press SELECT. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 34: Edit

    One access card can be assigned to each of the users on the control panel. To configure the access control for a user: 1. Scroll to USERS > EDIT. 2. Press SELECT. 3. Select the user which should be configured and press SELECT. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 35 2. Press SELECT. 3. Edit the desired user setting shown in the table below. 4. Press BACK to exit. Access Control Attribute Description Card Number Enter card number. Enter 0 to unassign this card. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 36: Delete

    1. Scroll to RESET CARD. 2. Press SELECT. 8.1.9.4 DELETE To delete users on the system: 1. Scroll to USERS > DELETE. 2. Press SELECT.  A prompt displays, confirming command to delete. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 37: User Profiles

    To delete user profiles on the system: 1. Scroll to USER PROFILES > DELETE. 2. Scroll through the user profiles to the required profile. 3. Press SELECT  You are prompted to confirm deletion. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 38: Sms

     The function SMS Authentication is activated in OPTIONS. 1. Scroll to SMS -> ADD and press SELECT. 2. Select a user to add for SMS operation. 3. Enter an SMS NUMBER for this user and press ENTER. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 39: Edit

    Commands, depending on SMS configuration, are sent using a PIN or caller ID. The type of PIN depends on what is set for SMS Authentication. The table below provides all available SMS commands. Subsequent action and response are also provided. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 40 Where mapping gate is Status of “O5” identified as “O5”, it is ****.O5.ON For example: triggered on. ****. OUTPUT Output O5 on.  Output heating on (where  heating is the name of the output.) Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 41: Change Pin

    The number of PIN digits varies on the security setting of the system. The system will not accept a PIN with fewer numbers than it is set to receive. Check with your installation engineer. 3. Confirm the new PIN and press SAVE. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 42: Door Control

    3. Select to ALLOW MANUFACT. and select ENABLED. 4. Select to GRANT SERVICE and enter the installer’s service ID. 5. To disallow engineer/manufacturer access, follow the same path and toggle to DISABLED and press SELECT. Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 43: Report To Eng

     The following types are displayed in this log: Zones  – Alarm – Panic System Events  – Confirmed Alarm – User Duress – XBus Panic – User Panic – RPA Panic Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 44: Appendix

    Isolating a zone deactivates that zone until such time Manager as the zone is de-isolated. All zone types on the can be isolated. Use of this feature to deactivate faulty or open zones Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 45 User can automatically override the Unset Delay. Only Manager available for Financial installations. See Setting/Unsetting Upgrade Manager User can grant manufacturer access to panel to perform firmware upgrade. X-10 Standard User can activate/deactivate configured X-10 devices. Manager Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 46: Zone Chart

    User can turn outputs (mapping gates) on and off. See Manager WPA Test Standard User can test a WPA. Manager * Functions not enabled by default for this user but can be selected. Zone chart Zone # Description Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 47: User Pins

     – Mains – Battery – PSU fault – Aux fault – External bell fuse – Internal bell fuse – Bell tamper – Cabinet tamper – Aux tamper 1 – Aux tamper 2 Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 48 Xbus over current – Installer name – Installer phone – Engineer enable – Manufacture enable – Reboot – Hardware fault – Aux over current – Battery low – Ethernet link – System name Vanderbilt Compact Keypad User Manual I-200004-1 01.10.2015...
  • Page 49 Issued by © Vanderbilt, 2015 Vanderbilt Technical specifications and availability subject to change without notice. Clonshaugh Business and Technology Park Clonshaugh Dublin D17 KV84 www.service.vanderbiltindustries.com Document ID I-200004-1 Edition 01.10.2015...

This manual is also suitable for:

Spck521

Table of Contents