LZV100 Command/Power Station
9.3 Using the LA152
Figure 10: Connecting the LA152
To use the LA152 with an LZV100 simply connect the LMAB
outputs on the rear of the LZV100 to the corresponding LMAB
connection on the rear of the first LA152. Additional LA152
adapters can then be connected using either four wire RJ14 or 6
wire RJ12 cables.
9.3.1
Using Multiple LA152s
You can install any combination of LA152 and or DIN sockets
around your layout that you like.
When interconnecting LA152s you can use either RJ11 4 wire
cable or RJ12 6 wire cable to connect Port A of one LA152 to Port
A of another LA152.
Figure 11: Module cable wiring
Care must be taken to use reverse style modular phone
cables (see above figure) to interconnect LA152s.
26