PID
PID Description
NOx Sensor Concentration Bank 1
NOX 12,22
Sensor 2, Bank 2 Sensor 2
SCR inducement system actual state
10K history HI1 (0-10000 km), 10K his-
NOX LEVEL HI,
tory HI2 (10000-20000 km), 10K his-
HI1, HI2, HI3,
tory HI3 20000-30000 km), 10K history
HI4
HI4 (30000-40000 km): NOx emission
too high
NOX_ADS_DE-
NOx Adsorber Desulfurization Status
SUL
NOX_ADS_RE-
NOx Adsorber Regen Status
GEN
Total Run Time by the Engien whicle
NWI_TIME
NOx warning mode is activated
O2 Voltage or Current indicates
O2S
Bank / Sensor
O2S11_PCT,
02 Sensor Concentration Bank 1 Sen-
O2S21_PCT
sor 1, Bank 2 Sensor 1
O2S12_PCT,
02 Sensor Concentration Bank 1 Sen-
O2S22_PCT
sor 2, Bank 2 Sensor 2
OBD2 STAT
OBD Status
OUT TEMP
Ambient Air Temp
PM Sensor Mass Concentration Bank
PM 11, PM 21
1 Sensor 1, Bank 2 Sensor 1
PNTE_Stat
PM NTE control area status
PTO STATUS
PTO Status
PTO_STAT
Power Take Off (PTO) Status
PTO_TIME
Total Run Time With PTO Active
Average Demanded Reagent
REAG_DEMD
Consumption
REAG_LVL
Reagent Tank Level
REAG_RATE
Average Reagent Consumption
REL FRP
Relative Fuel Rail Pressure
REL TPS
Relative Throttle Position
RUN_TIME
Total Engine Run Time
SCR inducement system actual state
10K history DEV1 (0 - 10000 km), 10K
SCR REAG DEV,
history DEV2 (10000 - 20000 km),
DEV1, DEV2,
10K history DEV3 (20000 - 30000 km),
DEV3, DEV4
10K history DEV4 (30000 - 40000 km):
deviation of reagent consumption
SCR inducement system actual state
10K history LOW1 (0 - 10000 km), 10K
SCR REAG
history LOW2 (10000 - 20000 km),
LOW, LOW1,
10K history LOW3 (20000 -
LOW2, LOW3,
30000 km), 10K history LOW4
LOW4
(30000 - 40000 km): reagent level too
low
SCR inducement system actual state
SCR RE-
10K history WRONG1 (0 - 10000 km),
AG WRONG,
10K history WRONG2 (10000 -
WRONG1,
20000 km), 10K history WRONG3
WRONG2,
(20000 - 30000 km), 10K history
WRONG3,
WRONG4 (30000 - 40000 km): incor-
WRONG4
rect reagent
SCR SYS AC-
SCR inducement system actual state:
TIVE
inducement system active
Distance travelled in current 10K block
SCR_DIST_1D
(0 - 10000 km)
Bosch Automotive Service Solutions Inc.
OBD 2220 Info Scan | User guide | 35 | en
PID
PID Description
Distance travelled while induce-
ment system active in current 10K
SCR_DIST_1N,
block 1N (0 - 10000 km), 20K block
2N, 3N, 4N
2N (10 - 20000 km), 30K block 3N
(20 - 30000 km), 40K block 4N
(30 - 40000 km)
SECOND AIR
Secondary Air Status
ST FTRM
Fuel Trim Bank / Sensor
ST FTRM1, 3
Short Term Fuel Trim1 or 3
ST FTRM2, 4
Short Term Fuel Trim2 or 4
ST SEC
Short Term Secondary O2 Sensor Fuel
FT1, 2, 3, 4
Trim 1, 2, 3, 4
TAC_A_CMD, B_
Commanded Throttle Actuator A Con-
CMD
trol, B Control
TAC_A_REL, B_
Relative Throttle A Position, B Position
REL
TCA_CINP, TCB_
Turbocharger Compressor Inlet Pres-
CINP
sure Sensor A, Pressure Sensor B
TCA_CINT, TCB_
Turbocharger A Compressor Inlet Tem-
CINT
perature, Turbocharger B
TCA_COUTT,
Turbocharger A Compressor Outlet
TCB_COUTT
Temperature, Turbocharger B
TCA_RPM, TCB_
Turbocharger A RPM, B RPM
RPM
TCA_TOUTT,
Turbocharger A Turbine Outlet Temper-
TCB_TOUTT
ature, Turbocharger B
TCA_TINT, TCB_
Turbocharger A Turbine Inlet Tempera-
TINT
ture, Turbocharger B
THROT CMD
Commanded Throttle Actuator Control
TP G
Absolute Throttle Position G
TQ_ACT
Actual Engine - Percent Torque
Driver's Demand Engine - Percent
TQ_DD
Torque
TQ_MAX1,
Engine percent torque at
MAX2, MAX3,
idle point 1, 2, 3, 4, 5
MAX4, MAX5
TQ_REF
Engine Reference Torque
TROUB CODE
Code causing the Freeze Frame
VEH SPEED
Vehicle Speed
VGT_A_ACT
Variable geometry turbo A position
VGT_A_ACT, B_
Variable Geometry Turbo A Position,
ACT
Turbo B
Commanded variable geometry turbo
VGT_A_CMD
A position
VGT_A_CMD, B_
Commanded Variable Geometry Turbo
CMD
A Position, Turbo B
Variable geometry turbo A control
VGT_A_STAT
status
VGT_A_STAT, B_
Variable Geometry Turbo A Control
STAT
Status, Turbo B
VGT_B_ACT
Variable geometry turbo B position
Commanded variable geometry turbo
VGT_B_CMD
B position
Variable geometry turbo B control
VGT_B_STAT
status
VPWR
Control Module Voltage
WG_A_ACT
Wastegate A position
WG_A_ACT, B_
Wastegate A Position, B Position
ACT