This manual is property of the owner. Leave with the unit when set-up and start-up are complete. Donaldson Company reserves the right to
change design and specifications without prior notice.
Illustrations are for reference only as actual product may vary.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
English
Master Language
Delta P Plus Control
Installation and Operation Manual
Installation, Operation, and Service Information
IOM AD3425201 (ENG)
Revision 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Delta P Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Donaldson Torit Delta P Plus

  • Page 1 Delta P Plus Control Installation and Operation Manual Installation, Operation, and Service Information This manual is property of the owner. Leave with the unit when set-up and start-up are complete. Donaldson Company reserves the right to change design and specifications without prior notice.
  • Page 2 Installation and Operations Manual. For a replacement manual, contact Donaldson Torit. This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures.
  • Page 3: Table Of Contents

    Delta P Plus Control Contents Description ................1 Delta P Plus Control Calibration ..........5 Operation ...................1 Optional Settings ..............7 Inspection on Arrival ...............2 Troubleshooting ................9 Electrical Wiring...............2 Replacement Parts ..............11 Installation.................2 Setpoint Adjustment ..............3 Quick Start Instructions ............3 Adjustments ................3 Password Protected Settings ..........3 DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 4: Description

    The Delta drop later approaches zero (indicating the blower P Plus Control also provides an input connection for a has been shut down), the Delta P Plus engages remote alarm reset/disable. the cleaning cycle for a pre-selected time. A delay...
  • Page 5: Inspection On Arrival

    6. Report incomplete shipments to the delivery carrier atmospheres without an enclosure rated for and your Donaldson Torit representative. the application. The Delta P Plus controller is Electrical Wiring factory set for 115 V. To operate at 230 V, the jumper settings on the printed Electrical installation, service, circuit board must be changed.
  • Page 6: Setpoint Adjustment

    Donaldson Company, Inc. 5. Wire all remaining auxiliary connections at this time. The AL setting selects the differential pressure drop See the Optional Settings and Connections section value used to close the Alarm relay and turn on the for a list of these options. Alarm pilot light on the display.
  • Page 7 Delta P Plus Control Setting Factory Parameters Description Units Function Range Default ALL - Combines differential pressure (Delta P) based cleaning with downtime cleaning ON/OFF selectable from keypad. DTC - Filters downtime cleaned only, not based on filter Delta P.
  • Page 8: Delta P Plus Control Calibration

    SET again. system. 7. After 10 seconds with no further button action, the 1. Turn power to the Delta P Plus Control ON for a display will return to reading the pressure. minimum of 30-minutes to stabilize the operating temperature.
  • Page 9 Delta P Plus Control high-pressure port dirty-air plenum low-pressure port clean-air plenum Delta P Plus Control Installation...
  • Page 10: Optional Settings

    Change from English to Metric (SI) Units Hi/Lo Control (TB3, Terminals 7, 8, & 9) 1. Turn power to the Delta P Plus Control ON. Per the wiring diagram supplied with the controller, the 2. Use the Menu key to select PAS.
  • Page 11 Delta P Plus Control R43 R42 R45 R46 4 2 1 side view autotran CONN 1 BKT1 C13 C19 C7 analog RA12 sensor R1R3 LED 1 LED 2 LED 3 "wg mm wg LED 1-3 Q8 Q6 ADDRESS RA11 Alarm...
  • Page 12: Troubleshooting

    Delta P Plus Control Fuse blown Check the fuse in the F1 fuse tower. Replace if necessary. Out of calibration Disconnect pressure tubing. See Delta P Plus Control Display on the Delta P Plus control does not Calibration. read zero when at rest...
  • Page 13 Remove the Program Disable jumper from Terminals 3 and 4 on TB2. Improper wiring Check wiring between the Delta P Plus Control and Cleaning light is ON, but cleaning system not the timer board, and between the timer board and functioning solenoid valve coils.
  • Page 14: Replacement Parts

    Keypad Label Printed Circuit Board Plastic Tubing Delta P Plus Control Item Part Number Description Model 7053601 Delta P Plus Control (includes keypad label and printed circuit board) 2334200 Plastic Tubing, Vinyl, 3/16-in ID, 5/16-in OD...
  • Page 16 The Donaldson Torit Warranty Donaldson warrants to the original purchaser that the major structural components of the goods will be free from defects in materials and workmanship for ten (10) years from the date of shipment, if properly installed, maintained and operated under normal conditions. Donaldson warrants all other Donaldson built components and accessories including Donaldson Airlocks, TBI Fans, TRB Fans, Fume Collector products and Donaldson built Afterfilters for twelve (12) months from date of shipment.