Page 3
Copyright All right reserved by our company, reprint,copy or sales of this manual are forbidden without our company permission. Responsibility Clause We are not responsibility for errors,omissions and variation without notice.
Page 4
Chapter 1 System Setting Enable/Disable Barcode Programming Scanning the Enter Setup/Exit Setup barcode can enable barcode programming. After barcode programming is enabled, you can scan a number of programming barcodes to configure your scanner. Barcode programming is on by default. In real application, programming barcodes hardly overlap witn h on- program m ing barcodes, so it is unnecessary to disable programming each...
Page 5
Transmit Programming Barcode Data W060F06 *Do Not Transmit Programming Barcode Data W060F00 Factory Defaults Scanning the following barcode can restore the scanner to the factory defaults. You may need to reset your scanner when: 1. scanner is not properly configured so that it fails to decode barcodes;...
Page 6
Scan Mode Manual Mode:A trigger pull activates a decode session. The decode session continues until the barcode is decoded or the trigger is released or the decode session timeout expires. *Manual Mode W030000 Decode Session Timeout: This parameter sets the maximum time decode session continues during a scan attempt.
Page 7
Continuous Mode Continuous Mode: A trigger press activates the scanner to scan and decode at user-specified intervals, i.e. the timeout between decodes. Each decode session lasts until barcode is decoded or decode session timeout expires. To suspend/resume the operation, simply press the trigger.
Page 8
Timeout between Decodes:This parameter sets the timeout between decode sessions. When a decode session ends, next session will not happen until the timeout between decodes expires. It is programmable in 0.1s increments from 0.0s to 25.5s. The default timeout is 1.0s. Timeout between Decodes M00031C Example: Set the timeout between decodes to 5s...
Page 9
Reread Delay sets the time period before the scanner can read the same barcode a second time. It protects against accidental rereads of the same barcode. This parameter is programmable in 0.1s increments from 0.1s to 25.5s. The default delay is 3.0s. If the parameter is set to 0, the delay is infinite.
Page 10
Sense Mode Sense Mode: The scanner activates a decode session every time when it detects a change in ambient illumination and meets the requirement of the image stabilization timeout. Decode session continues until barcode is decoded or the decode session timeout expires. A trigger pull can also activate a decode session.
Page 11
Image Stabilization Timeout: The scanner waits for the image stabilization timeout to expire before activating a decode session every time it detects a change in ambient illum ination. This parameter is program m able in 0.1s increments from 0.0s to 25.5s. The default timeout is 0.4s.
Page 12
Reread Same Barcode with No Delay: The scanner is allowed to reread same barcode, ignoring the Reread Same Barcode with a Delay: The scanner is not allowed to reread same barcode before the reread delay expires. To disable rereads of same barcode, enable the Reread Same Barcode with a Delay and set the delay to 0.
Page 13
Sensitivity: This parameter specifies the degree of acuteness of the scanner’s response to changes in ambient illumination. The higher the sensitivity, the lower requirement in illumination change to trigger the scanner. You can select an appropriate degree of sensitivity that fits the ambient environment. High Sensitivity WFF0305 Medium Sensitivity...
Page 14
Command Trigger Mode Command Trigger Mode: Decode session is activated by a host command. The decode session continues until the barcode is decoded or the decode session time out expires. Command Trigger Mode W030001 Decode Session Timeout: This parameter sets the maximum time decode session continues during a scan attempt.
Page 15
Security Level This parameter specifies the number of times to decode a barcode during a scan attempt. The higher the security level, the lower the error rate and decoding efficiency. Set Security Level to W030A00 Set Security Level to W030A01 Set Security Level to W030A02 Set Security Level to 3...
Page 16
Good Read Beep Good Read Beep Off W041200 *Good Read Beep On W041204 Good Read Beep Frequency WFF10DA *Medium WFF104B High WFF1025...
Page 17
Good Read Beep Duration 40ms WFF111F *80ms WFF111E 120ms WFF111D Decode Result Notification *Enable Decode Result Notification W203120 Disable Decode Result Notification W203100...
Page 18
Other Settings You can change the following parameter settings temporarily and the changes will be lost when you power down or reboot the scanner. Silent Mode On W400000 *Silent Mode Off W400040 Note: This feature is only applicable to decode beep and will be automatically disabled when the scanner is powered down or rebooted.
Page 19
Chapter 2 Communication Settings Introduction The scanner provides an RS-232 interface, a USB interface and a PS/2 interface (hardware version: V2 or higher) to communicate with the host device. The host device can receive scanned data and send commands to control the scanner or to access/alter the configuration information of the scanner via the RS-232 or USB or PS/2 interface.
Page 21
Parity Check *None W062900 Even Parity W062906 Odd Parity W062904 Stop Bit *Stop Bit W012900 2 Stop Bits W012901...
Page 22
Data Bit 8 Data Bits W082908 *8 Data Bits, No Parity, 1 Stop Bit W0F2908 8 Data Bits, Even Parity, 1 Stop Bit W0F290E 8 Data Bits, Odd Parity, 1 Stop Bit W0F290C 8 Data Bits,No Parity, 2 Stop Bits W0F2909 8 Data Bits, Even Parity , 2 Stop Bits...
Page 23
8 Data Bits, Odd Parity, 2 Stop Bits W0F290D 7 Data Bits W082900 7 Data Bits, Even Parity, 1 Stop Bit W0F2906 7 Data Bits, Odd Parity, 1 Stop Bit W0F2904 7 Data Bits, Even Parity, 2 Stop Bits W0F2907 7 Data Bits, Odd Parity, 2 Stop Bits W0F2905...
Page 24
USB Interface When the scanner is connected to a host device through its USB interface, USB HID-KBW is enabled by default. User can switch between options – USB DATAPIPE, USB HID-KBW, USB COM Port Emulation and HID-POS, upon actual need. *USB HID-KBW W070901 *Standard Keyboard...
Page 25
Function Key Mapping When Function Key Mapping is enabled, function character (0x00 - 0x1F) are sent as ASCII sequences over the numeric keypad. Function Key Mapping W031A01 1. CTRL Make 2. Press function key (Refer to the ASCII Function Key Mapping Table on the following page) USB Country Keyboard Types Keyboard layouts vary from country to country.
Page 26
3- Brazil WFF1902 4- Canada WFF1903 Czech WFF1904 Denmark WFF1905 Finland WFF1906 France WFF1907...
Page 27
Austria WFF1908 Greece WFF1909 Hungary WFF190A Israel WFF190B Italy WFF190C WFF190D...
Page 28
15- Netherland WFF190E 16- Norway WFF190F 17- Poland WFF1910 18- Portugal WFF1911 19- Romania WFF1912 20- ussia WFF1913...
Page 30
27- UK WFF191B 28- Japan WFF191C Inter-Keystroke Delay This parameter specifies the delay between emulated keystrokes. *No Delay WC01A00 Short Delay (5ms) WC01A40 Medium Delay (10ms) WC01A80 Long Delay (15ms) WC01AC0...
Page 31
Convert Case This parameter is valid when the Standard Keyboard or Function Key Mapping is enabled. No Case Conversion W381A00 Convert All to Upper Case W381A20 Convert All to Lower Case W381A30 Invert Upper and Lower Case Characters W381A08...
Page 32
Emulate Numeric Keypad When this feature is disabled, sending barcode data is emulated as keystroke(s) on main keyboard. To enable this feature, scan the Emulate Numeric Keypad barcode. Sending a number (0-9) is emulated as keystroke on numeric keypad, whereas sending other character like “+”, “_”, “*”...
Page 33
USB COM Port Emulation This feature allows the host to receive data in the way as a serial port does. However, you need to set communication parameters on the scanner to match the Host requirements. A driver is required for this feature. USB COM Port Emulation W070902 USB DataPipe...
Page 34
HID-POS The HID-POS interface is recommended for new application programs. It can send up to 56 characters in a single USB report and appears more efficient than USB HID-KBW. Features: HID based, no custom driver required. ² □ Way more efficient in communication than USB HID-KBW and traditional RS-232 interface.
Page 35
Chapter 3 Data Formatting Introduction After a successful barcode read, a string containing numbers, letters or symbols will be returned. In real applications, barcode data may be found insufficient for your needs. You may wish to include additional information such as barcode type, data acquisition time or delimiter in data being scanned.
Page 36
Prefix Enable Custom Prefix W043104 *Disable Custom Prefix W043100 Set Custom Prefix W000100 Enable AIM ID Prefix W186018 *Disable AIM ID Prefix W186000...
Page 37
Enable CODE ID Prefix W023102 *Disable CODE ID Prefix W023100 Restore All Default Code IDs WFFD9C2 Set Code ID Barcodes Set Code 128 Code ID M002000 Set UCC/EAN-128 Code ID M002001 M002002...
Page 39
Set EAN-8 Code ID M002004 Set EAN-13 Code ID M002005 Set ISSN Code ID M002006 Set ISBN Code ID M002007 Set UPC-E Code ID M002008 Set UPC-A Code ID M002009...
Page 40
Set Interleaved 2 of 5Code ID M00200A Set ITF-6 Code ID M00200B Set ITF-14 Code ID M00200C Set Deutsche 14 Code ID M00200D Set Deutsche 12 Code ID M00200E Set Matrix 2 of 5 Code ID M00200F...
Page 41
Set Industrial 25 Code ID M002010 Set Standard 25 Code ID M002011 Set Code 39 Code ID M002012 Set Codabar Code ID M002013 Set Code 93 Code ID M002014 Set Code 11 Code ID M002015...
Page 42
Set Plessey Code ID M000216 Set MSI-Plessey Code ID M000217 RSS-14 Code ID M000218 RSS-Limited Code ID M000219 Set RSS-Expand Code ID M00021A...
Page 43
Suffix Enable Custom Suffix W083108 *Disable Custom Suffix W083100 Set Custom Suffix M000101 *Enable Terminating Character Suffix W103110 Disable Terminating Character Suffix W103100...
Page 44
Terminating Character 0x0D WFFD9C3 Terminating Character 0x0D,0x0A WFFD9C4 Terminating Character 0x0 WFFD9C5 Set Terminating Character Suffix M000102...
Page 45
Chapter 4 Symbologies Introduction Every symbology (barcode type) has its own unique attributes.This chapterprovides programming barcodes for configuring the scanner so that it can identify various barcode symbologies. It is recommended to disable those that are rarely used to increase the efficiency of the scanner.
Page 46
Restore the Factory Defaults UCC/EAN-128 WFFD991 Enable UCC/EAN-128 W036203 Disable UCC/EANI-128 W036200 Decode as Code 128 W036201 Restore the Factory Defaults of AIM128 WFFD992 Enable AIM128 W036302...
Page 48
Restore the Factory Defaults of ISSN WFFD966 Enable ISSN W036702 *Disable ISSN W036700 Decode as EAN-13 W036701...
Page 49
Restore theFactory Defaults of ISBN WFFD997 Enable ISBN W036802 *Disable ISBN W036800 Decode as EAN-13 W036801 Restore the Factory Defaults of UPC-A WFFD999 *Enable UPC-A W036B02...
Page 50
Disable UPC-A W036B00 Decode as EAN-13 W036B01 Restore the Factory Defaults of Interleaved 2 Of 5 WFFD99A *Enable Interleaved 2 of 5 W016C01 Disable Interleaved 2 of 5 W016C00...
Page 51
Restore the Factory Defaults of ITF-6 WFFD99B Disable ITF-6 W036D01 Enable ITF-6 But Do Not Transmit Check Digit W036D02 Enable ITF-6 and Transmit Check Digit W036D0A Restore theFactoryDefaults of ITF-14 WFFD99C Disable ITF-14 W036E01...
Page 52
Enable ITF-14 But Do Not Transmit Check Digit W036E02 Enable ITF-14 and Transmit Check Digit W036E0A Restore theFactoryDefaults of Deutsche 14 WFFD99D Disable Deutsche 14 W036F01 Enable Deutsche14 But Do Not Transmit Check Digit W036F02...
Page 54
Restore the Factory Defaults of Deutsche 12 WFFD99E Disable Deutsche 12 W037001 Enable Deutsche 12 But Do Not Transmit Check Digit W0B7002 Enable Deutsche 12 and Transmit Check Digit W0B700A WFFD99F...
Page 55
Restore the Factory Defaults of Matrix 2 of 5...
Page 56
Disable Matrix 2 of 5 W017100 Restore the Factory Defaults of Industrial 25 WFFD9A0 *Enable Industrial 25 W017201 Disable Industrial 25 W017200 WFFD9A1...
Page 57
Restore the Factory Defaults of Standard 25...
Page 58
Disable Standard 25 W017300 Restore the Factory Defaults Code 39 WFFD922 *Enable Code 39 W017401 Disable Code 39 W017400 *Enable Code 39 Full ASCII W207402...
Page 59
Restore the Factory Defaults of Codabar WFFD9A3 *Enable Codabar W017501 Disable Codabar W017500 Restore the Factory Defaults Code 93 WFFD9A4 *Enable Code 93 W017601...
Page 63
Enable EAN-8 Zero Extend WC06540 *Disable EAN-8 Zero Extend W C06500 Convert EAN-8 to EAN-13 WC06580 Restore the Factory Defaults of EAN-13 WFFD995 *Enable EAN-13 W016601 Disable EAN-13 W016600...
Page 64
Restore the Factory Defaults of UPC-E WFFD998 *Enable UPC-E W016901 Disable UPC-E W016900 Enable UPC-E Extend WC06940 *Disable UPC-E Extend W C06900 Convert UPC-E to UPC-A WC06980...
Page 65
*Enable Code 39 Full ASCII W207420 Disable Code 39 Full ASCII W207400...
Page 66
Set Length Range Set the Minimum Length for Code 128 M000301 Set the Maximum Length for Code 128 M000300 Set the Minimum Length for UCC/EAN-128 M000303 Set the Maximum Length for UCC/EAN-128 M000302 Set the Minimum Length for AIM 128 M000305...
Page 67
M000304 Set the Maximum Length for AIM 128...
Page 68
Set the Minimum Length for Interleaved 2 of 5 M000307 Set the Maximum Length for Interleaved 2 of 5 M000306 Set the Minimum Length for Matrix 2 of 5 M000309 Set the Maximum Length for Matrix 2 of 5 M000308 Set the Minimum Length for Industrial 25 M00030B...
Page 70
Set the Minimum Length for Industrial 25 M00030D Set the Maximum Length for Industrial 25 M00030C Set the Minimum Length for Code 39 M00030F Set the Maximum Length for Code 39 M00030E Set the Minimum Length for Codabar M000311 Set the Maximum Length for Codabar M000310...
Page 71
Set the Minimum Length for Code 93 M000313 Set the Maximum Length for Code 93 M000312 Set the Minimum Length for Code 11 M000315 Set the Maximum Length for Code 11 M000314 Set the Minimum Length for Plessey M000317 Set the Maximum Length for Plessey M000316...
Page 72
Set the Minimum Length for MSI-Plessey M000319 Set the Maximum Length for MSI-Plessey M000318 Example: Set the scanner to decode MSI- Plessey barcodes containing between 8 and 12 characters. 1. Scan the Enter Setup barcode. 2. Scan the Set the Minimum Length barcode. 3.
Page 73
Transmit Check Digit *Transmit EAN-8 Check Digit W046504 Do Not Transmit EAN-8 Check Digit W046500 *Transmit EAN-13 Check Digit W046604 Do Not Transmit EAN-13 Check Digit W046600 *Transmit UPC-E Check Digit W046904...
Page 74
W046900 Do Not Transmit UPC-E Check Digit...
Page 75
*Transmit UPC-A Check Digit W086B08 Do Not Transmit UPC-A Check Digit W086B00 Check Digit Verification Example: Set the scanner for check digit Interleaved 2 of 5. A check digit is optional for Interleaved 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data.
Page 76
Disable W0C6C00 Do Not Transmit Check Digit After Verification W0C6C04 Transmit Check Digit After Verification W0C6C0C...
Page 77
A check digit is optional for Matrix 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Matrix 2 of 5 barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Matrix 2 of 5 barcodes to verify that the data complies with...
Page 78
A check digit is optional for Industrial 25 and can be added as the last digit. It is a calculatedvalue used to verify the integrity of the data. Disable: The scanner transmits Industrial 25 barcodes as is.Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Industrial 25 barcodes to verify that the data complies with the check digit algorithm.
Page 79
A check digit is optional for Standard 25 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Standard 25 barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Standard 25 barcodes to verify that the data complies with the check digit algorithm.
Page 80
A check digit is optional for Code 39 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Code 39 barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check digit algorithm.
Page 81
A check digit is optional for Codabar and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Codabar barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check digit algorithm.
Page 82
Check digits are optional for Code 93 and can be added as the last two digits, which are calculated valuesused to verify the integrity of the data. Disable: The scanner transmits Code 93 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Code 93 barcodes to verify that the data complies with the check digit algorithm.
Page 83
Check digits are optional for Plessey and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Plesseybarcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Plessey barcodes to verify that the data complies with the check digit algorithm.
Page 84
Check digits are optional for Code 11 and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data. If the Disable option is enabled, the scanner transmits Code 11 barcodes as is.
Page 85
Transmit Check Digit W107910 *Do Not Transmit Check Digit W107900 Add-On Code An EAN-8 barcode can be augmented with a two- digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is add-on code.
Page 87
Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of EAN-8 barcodes with and without 2-digit/5-digit add-on codes. Disable 2-Digit Add-On Code/ Disable 5-Digit Add- On Code: The scanner decodes EAN-8 and ignores the add-on code when presented with an EAN-8 plus add-on barcode.
Page 89
Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of EAN-13 barcodes with and without 2-digit/5-digit add-on codes. Disable 2-Digit Add-On Code/ Disable 5-Digit Add- On Code: The scanner decodes EAN-13 and ignores the add-on code when presented with an EAN-13 plus add-on barcode.
Page 90
A UPC-E barcode can be augmented with a two- digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is add-on code. Enable 2-Digit Add-On Code W106910 *Disable 2-Digit-Add-On Code...
Page 91
*Disable 5-Digit Add-On Code W206900 UPC-E Add-On Code Required W086908 *UPC-E Add-On Code Not Required W086900 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of UPC-E barcodes with and without 2-digit/5-digit add-on codes. Disable 2-Digit Add-On Code/ Disable 5-Digit Add-On Code: The scanner decodes UPC-E and ignores the add-on code when presented with a UPC-E plus add-on barcode.
Page 92
A UPC-A barcode can be augmented with a two- digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is add-on code. Enable 2-Digit Add-On Code W206B20 *Disable 2 Digit Add-On Code...
Page 93
Enable 5-Digit Add-On Code W206B40 *Disable5-Digit Add-On Code W206B00 UPC-A Add-On Code Required W106B10 *UPC-A Add-On Code Not Required W106B00 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of UPC- Abarcodes with and without 2-digit/5-digit add-on codes.
Page 94
Transmit Start/Stop Characters Transmit Start/Stop Characters code39 W047404 *Do Not Transmit Start/Stop Characters code39 W047400 Transmit Start/Stop Characters W047504 DO Not Transmit Start/Stop Characters W047500 *ABCD/ABCD as the Start/ Stop CharacterS W187500 W187508...
Page 95
ABCD/TN*E as the Start/ Stop Characters...
Page 96
abcd/abcd as the Start/ Stop Character W187510 abcd/tn*e as the Start/ Stop Character W187518 Set ISBN Format *ISBN-13 W086800 ISBN-10 W086808...
Page 97
Transmit Preamble Character Preamble characters (Country Code and System Character) can be transmitted as part of a UPC- Abarcode. Select one of the followingoptions for transmitting UPC-Apreamble to the host device: transmit system character only, transmit system character and countrycode ("0" for USA), or transmit no preamble.
Page 98
*Transmit UPC-A Check Digit W086B08 Do Not Transmit UPC-A Check Digit W086B00 Check Digit Verification Interleaved 2 of 5 A check digit is optional for Interleaved 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data.
Page 99
Disable W0C6C00 Do Not Transmit Check Digit After Verification W0C6C04 Transmit Check Digit After Verification W0C6C0C Matrix 2 of 5 A check digit is optional for Matrix 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data.
Page 100
*Disable W0C7100 Do Not Transmit Check Digit After Verification W0C7104 Transmit Check Digit After Verification W0C710C Industrial 25 A check digit is optional for Industrial 25 and can be added as the last digit. It is a calculated value used to verify the integrity of the data.
Page 101
*Disable W0C7200 Do Not Transmit Check Digit After Verification W0C7204 Transmit Check Digit After Verification W0C720C Standard 25 A check digit is optional for Standard 25 and can be added as the last digit. It is a calculated value used to verify the integrity of the data.
Page 102
*Disable W0C7300 Do Not Transmit Check Digit After Verification W0C7304 Transmit Check Digit After Verification W0C730C Code 39 A check digit is optional for Code 39 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Code 39 barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Code 39 barcodes...
Page 103
*Disable W187400 Do Not Transmit Check Digit After Verification W187408 Transmit Check Digit After Verification W187418 Codabar A check digit is optional for Codabar and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Codabar barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Codabar...
Page 104
*Disable W607500 Do Not Transmit Check Digit After Verification W607520 Transmit Check Digit After Verification W607560 Code 93 Check digits are optional for Code 93 and can be added as the last two digits, which are calculated values used to verify the integrity of the data.
Page 105
Disable W0C7600 *Do Not Transmit Check Digit After Verification W0C7604 Transmit Check Digit After Verification W0C760C Plessey Check digits are optional for and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Plessey barcodes as Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Plessey barcodes...
Page 106
Disable W0C7800 After Verification W0C7804 Transmit Check Digit After Verification W0C780C Code 11 Check digits are optional for Code 11 and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data.
Page 107
Disable W0C7900 *One Check Digit,MOD10 W0C7904 Two Check Digits, MOD10/MOD10 W0C7908 Two Check Digits, MOD10/MOD W0C790C Transmit Check Digit W0C7910 *Do Not Transmit Check Digit W0C7900...
Page 108
Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN- 8 barcode while the part circled by red dotted line is add- on code.
Page 109
Enable 5-Digit Add-On Code W206520 *Disable 5-Digit Add-On Code W206500 EAN-8 Add-On Code Required W086508 *EAN-8 Add-On Code Not Required W086500 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of EAN-8 barcodes with and without 2-digit/5-digit add-on codes.
Page 110
An EAN-13 barcode can be augmented with a two- digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is add-on code. Enable 2-Digit Add-On Code W106610 *Disable 2-Digit Add-On Code...
Page 111
Enable 5-Digit Add-On Code W206620 *Disable 5-Digit Add-On Code W206600 EAN-13 Add-On Code Required W086608 *EAN-13 Add-On Code Not Required W086600 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of EAN-13 barcodes with and without 2-digit/5-digit add-on codes.
Page 112
Transmit System Character The first character of UPC-E barcode is the system character Do Not Transmit System Character W306A10 Transmit System Character W306A20 A UPC-E barcode can be augmented with a two- digit or five-digit add-oncode to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is add-on code.
Page 114
UPC-E Add-On Code Required W086908 *UPC-E Add-On Code Not Required W086900 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of UPC-E barcodes with and without 2-digit/5-digit add-on codes. Disable 2-Digit Add-On Code/Disable 5-Digit Add- On Code: The scanner decodes UPC-E and ignores the add-on code when presented with a UPC-E plus add-on barcode.
Page 115
A UPC-A barcode can be augmented with a two- digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is add-on code. Enable 2-Digit Add-On Code W206B20 *Disable 2-Digit Add-On Code...
Page 116
Enable 5-Digit Add-On Code W406B40 *Disable 5-Digit Add-On Code W406B00 UPC-A Add-On Code Required W106B10 *UPC-A Add-On Code Not Required W106B00 Enable 2-Digit Add-On Code/ Enable 5-Digit Add- On Code: The scanner decodes a mix of UPC- Abarcodes with and without 2-digit/5-digit add-on codes.
Page 118
ABCD/TN*E as the Start/ Stop Character W187508 abcd/abcd as the Start/ Stop Character W187510 abcd/tn*e as the Start/ Stop Character W187518 Set ISBN Format *ISBN-13 W086800 ISBN-10 W086808...
Page 119
Transmit Preamble Character Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-A . Select one of the following barcode options for transmitting UPC-Apreamble to the host device: transmit system character only, transmit system character and country code (“0” for USA), or transmit no preamble.
Appendix Factory Defaults Table Parameter Remark Factory Default System Settings Barcode Programming Enabled Program m ing Barcode D ata D o not send M anual M ode Scan Mode 1 -255s; 0: infinite. M anual M ode Decode Session Timeout 15 s 1 -255s;...
Page 121
Factory Default Remark Parameter Communication Interfaces Baud Rate 9600 Parity Check N one TTL - 232 Interface N um ber of D ata Bits N um ber of Stop Bits Flow C ontrol N one Other options:DataPipe,USB USB Interface USB HID-KBW COM Port Emulation, HID-POS Input Mode Standard Keyboard...
Page 122
Factory Default Remark Parameter EAN-13 EAN -13 Enabled C heck D igit Transm it 2-Digit Add-On Code D isabled 5-Digit Add-On Code Not required Add-O n C ode D isabled ISSN D isabled ISSN ISBN ISBN D isabled ISBN Format ISBN-13 UPC-E UPC-E...
Page 123
Factory Default Remark Parameter Deutsche14 D eutsche14 D ecode as I25 Transm it C heck D igit D eutsche12 D eutsche12 D ecode as I25 C heck D igit Transm it Matrix 2 of 5 Matrix 2 of 5 Enabled C heck D igit Verification D isabled Check Digit...
Page 124
Factory Default Remark Parameter Code93 Enabled C ode 93 C heck D igit Verification Enabled Check Digit Do not transmit Minimum Length No less than 1 (including check digit) Maximum Length Code11 D isabled C ode 11 C heck D igit Verification O ne check digit,M O D 1 1 Check Digit Do not transmit...
AIM ID Table Symbology AIM ID Remark C ode 128 Standard C ode 128 UCC/EAN 128 FN C 1 is the character right after the start character (GS1-128) AIM 128 FN C 1 is the 2nd character after the start character Standard EAN -8 EAN -8 ]E4….]E1…...
Page 126
AIM ID Symbology Remark Standard C odabar ABC Codabar C odabar Transmit check digit afte verificationr Do not transmit check digit after verification Not specified C ode 93 ]H 0 One check digit, MOD11; transmit check digit Tw o check digits, M O D 11/M O D 11; transm it check digit ]H 1 C ode 11 ]H 3...
Code ID Table Symbology Code ID C ode 128 U C C /EAN -128 AIM 128 SETTING 128 EAN -8 EAN -13 ISSN ISBN UPC-E UPC-A Interleaved 2 of 5 ITF-6 ITF-14 D eutsche 14 D eutsche 12 Industrial 25 Standard 25 C ode 39 C odabar...
Page 136
Save/Cancel Barcodes After reading numeric barcode(s), you need to scan the Save barcode to save the data. If you scan the wrong digit(s), you can either scan the Cancel the Last Digit barcode and then the correct digit, or scan the Cancel All Digits barcode and then the digits you want.
Page 137
A ~ F D00000A D00000B D00000C D00000D D00000E D00000F...
Need help?
Do you have a question about the MS836 and is the answer not in the manual?
Questions and answers