SIATA SFE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIATA and is the answer not in the manual?

Questions and answers

Summary of Contents for SFE SIATA

  • Page 1 S F E SIATA SFE MANUAL...
  • Page 2: Table Of Contents

    INDEX 1-DECLARATION OF CONFORMITY 2-General Instructions 3-General Features 4-Functions 4.1 Description of the control panel 4.2 Display 4.2.1 Display in Service 4.2.2 Display in Regeneration 4.2.3 Display during battery operation 4.3 General Information before programming 4.4 Manual Regeneration 4.5 Microswitch search 4.6 Salt Recharge 4.7 Statistics Menu 4.8 Reset eeprom...
  • Page 3: Declaration Of Conformity

    1 - DECLARATION OF CONFORMITY The products of series Timer S F E Comply with the following Directives: 2006/42/EC: Machinery Directive 2006/95/EC: Low Voltage Directive 2004/108/EC: Electromagnetic Compatibility Meet the following technical standards: EN 61010-1: Safety provisions for electrical measurement, control and laboratory equipment - Part 1: general provisions.
  • Page 4: General Instructions

    2 - GENERAL INSTRUCTION Read this user and maintenance manual carefully before using the device. The controller must be installed by qualified personnel; the installation procedures must be carried out with equipment switched off. Package and storage The equipment is packaged in a formed polystyrene frame and contained in a cardboard box. No special procedures are required for unpacking.
  • Page 5: General Features

    3 - GENERAL FEATURES The SFE controller allows the management of softening and filtering systems. The controller is based on two electronic boards for TC & metered versions SFE is available with 2 different electronic boards: standard 7930-23 or chlorine cell control 7930-24.
  • Page 6 4 - OPERATION 4.1 Control panel description Buttons description Description It is used to edit the displayed value during a programming step. Press it together with the arrow up Down arrow key for 5 seconds to open the advanced settings menu. Press and release to access the basic settings menu.
  • Page 7: Display

    4.2 Display 1. Service status icon; 2. Weekdays icon; 3. Time display mode icon; 4. Programming parameters/regeneration status/time digit; 5. Power supply status icon (if it is enabled it indicates a lack of mains supply and storage of the programming data to the memory); 6.
  • Page 8: Display During Battery Operation

    4.2.2 Display during regeneration When the module is in regeneration, the display shows the following information: • During the transition phases nC-|, where n is the number of the regeneration cycle phase, a turning bar is display to mean that a transition is occurring from a regeneration phase to the next one. Transition to phase 1 • During the stopping phases nCxx|, where n is the number of the regeneration cycle phase and xx are the residual minutes before switching to the next phase.
  • Page 9: General Information Before Programming

    Battery-operated status 4.3 General information before programming The SFE controller allows to manage your installation by a time clock control or by a volumetric control. The controller will automatically initiate regenerations cycles based upon the programmed regeneration mode and the programmed parameters.
  • Page 10: Microswitch Search

    When Delayed manual regeneration is chosen current day of the week and service icon are going to blink until regeneration starts Day of the week and service icon blink to confirm Delayed Manual Regeneration 4.5 Microswitch search When powering the module may sometimes display F1-| or F2-| where the number indicates if we are carrying out the first or the second microswitch search attempt, a turning bar is also shown to indicate that the motor is on.
  • Page 11: Reset Eeprom

    The treated volume is displayed on a running string so as to allow reading a number greater than 9999. Press to switch parameters . The date and time information for the last regenerations carried out are only available if regenerations have been carried out.
  • Page 12: Power Failure

    4.9 Power failure The following conditions may occur in the event of a power failure: The power failure occurs during the standby phase, during a parameter reset phase, during the statistics analysis phase. In all these cases, the module returns to stand by and displays the clock with the battery on icon, meaning a power failure.
  • Page 13: Programming

    5 - PROGRAMMING 5.1 Basic programming The most common operating parameters are set in the basic menu. To access the basic menu, press and release the button. The basic menu contains the following parameters: DATA DESCRIPTION DEFAULT MIN - MAX 12H –...
  • Page 14: Advanced Programming

    5.2 Advanced programming The module operating parameters are set in the advanced menu. Press at the same time for 5 seconds to open this menu. DATA DESCRIPTION DEFAULT MIN - MAX Regeneration start mode: 0 - Regeneration start at the time set during the enabled days. 1 - Regeneration start at the time set after the volume treatment in the enabled days.
  • Page 15 DATA DESCRIPTION DEFAULT MIN - MAX Duration of the third regeneration cycle stop (minutes). Press Of-99 to edit. If the parameter is set to off, the stop will be skipped and the system will directly go to the next stop. Duration of the fourth regeneration cycle stop (minutes).
  • Page 16 Note 1: calculation of number of regenerations before a salt alarm is generated. The following formula is used to calculate the number of regenerations before a salt alarm is generated: SA = (M.xxx) * 1000 SA = (M.xxx) * 1000 (L.xxx) x (G.xxx) where: M.xxx: amount (in kg) of salt found in the brine tank;...
  • Page 17 5.3 Programmamable Regeneration Modes...
  • Page 18: Error Message

    Microswitch alarm. The module cannot find the service position. No regenerations are carried out during the microswitch alarm. RESET HARDWARE The SFE controller is fitted with a hardware reset button located on the board itself close to the display and not directly reachable by the user. Hardware reset button Button to reset the SFE board After a hardware reset, the time on the display flashes until any button is pressed.
  • Page 19: Installation

    7 - INSTALLATION The SFE controller may be installed on the following of SIATA valves: V132, V230, V250 (with the accessory 5191-P). NOTE: a whole series of accessories is available for installation on the following valves: V240, V260, V360. 7.1 Installation with V132/V230 Valves...
  • Page 20 Exploded view of the SFE controller on the V132 valve Key: 1 Valve v132 2 Self-threading screw din 7981c st 2.9x16 (code 101) 3 Support with electronic board and cam for twin pilot 4 Self-scraping screw din 7981c st 2.9x25 (code 104)
  • Page 21 7.2 Installation on valve V250 The bracket needed is delivered with the valve.
  • Page 22 Exploded view of the SFE controller on the V250 valve Key: 1 Cover timer (code 81-pb2) 2 Support with electronic board and external pilots 3 Flat washer iso 7089 6.4x12 th. 1.6 (code 5182-r) 4 Self-threading screw din 7981c st 2.9x16 (code 101)
  • Page 23 TWIN PILOT SFE TIMER SPARE PARTS LIST Controller SFE twin pilots ITEM NO. PART NO. DESCRIZIONE DESCRIPTION Blocca cavo Cord lock 95-STD1 Trasformatore 230/12 vac 230/12 ac power supply 95-ST1 Trasformatore 230/12/12 230/12/12 ac power supply for solenoid 95-STC1 Trasformatore 230/12/6...
  • Page 24 Controller plate and label kit K-7930-03 Scheda elettronica sfe SFE electronic card K-7930-02 Scheda elettronica sfe cloro SFE electronic card - chloride 94-R7K/05 Kit motore 12 vac, 1 rpm 12 vac motor, 1 rpm kit Box standard Box standard 2253-BM/05...
  • Page 25 Controller SFE LPlate twin pilots ITEM NO. PART NO. DESCRIZIONE DESCRIPTION 81-PLBK1 Kit supporto controller Controller backplate kit 88-L2/05 Kit microswitch con supporto Microswitch and housing kit 95-STD1 Trasformatore 230/12 vac 230/12 ac power supply 95-ST1 Trasformatore 230/12/12 230/12/12 ac power supply...
  • Page 26 Timer SFE LPlate external pilots ITEM NO. PART NO. DESCRIZIONE DESCRIPTION 95-STD1 Trasformatore 230/12 vac 230/12 ac power supply 95-ST1 Trasformatore 230/12/12 230/12/12 ac power supply for solenoid 95-STC1 Trasformatore 230/12/6 230/12/6 ac power supply for chlore 2221-*/05 Kit camma esterna...
  • Page 27 (*).The code of the cam kit 2221-* depends on the type of cam used. Refer to customer care service for the right code. Some code examples are in table A. (**):The code of kit 468*-K1 depends of the type of cam used. Refer to table A.
  • Page 28 SPARES KIT SPARE KIT CONTENTS CODE 81-PLBK1 81-PLB K1-90-XP 90-XP K-10017 BR40422 21759 K-92-F 92-F 94-R7K/05 94-SR7 114-DX K-7930-03 7930-03 K-7930-04 7930-04 81-PB2-K1 81-PB2 862-SFE K-88-A 88-A 468X-K1** 468-X** 468-R 468-D 468-D3 2221-XXXX* 119-L/05 84-SEG2/05 425-XXXXX 2229/05 84-SEG2/05 84-L/05 119-L/05...
  • Page 29: Connection Diagrams

    ELECTRICAL CONNECTION DIAGRAM 7930-03 MOTHERBORD 7930-03 METER CONNECTOR INHBIT/START REMOTE MOTOR 97-SR7 CONNECTOR MICROSWITCH 02-F WIRED CONNECTOR 40696 12VAC/DC EXTERNAL ELECTROVALVE ELECTROVALVE CABLE 2229-50 TRANSFORMER 96-ST1 EXTERNAL METER CABLE A10033 INHBIT/START REMOTE CABLE A-10034 WIRE JOINT BR40422 VOLUMETRIC SENSOR 2223-50...
  • Page 30 ELECTRICAL CONNECTION DIAGRAM 7930-04 MOTHERBORD 7930-04 METER CONNECTOR INHBIT/START REMOTE MOTOR 94-SR7 CONNECTOR MICROSWITCH 92-F WIRED CONNECTOR 40696 6 VDC EXTERNAL CHLORDE PRODUCER CHLORDE CABLE 2226-C45 TRANSFORMER 96-STC1 EXTERNAL METER CABLE A10033 INHBIT/START REMOTE CABLE A-10034 VOLUMETRIC WIRE JOINT BR40422 SENSOR 2223-50...
  • Page 31 Electrical connection diagram – SFE with SIATA meter or generic magnetic meter Electrical connection diagram - SFE with reed sensor meter...