Arada Stratford Ecoboiler User Manual

Ecoboiler cassette stove
Hide thumbs Also See for Stratford Ecoboiler:

Advertisement

Ecoboiler Cassette Stove User Guide
Ecoboiler Cassette
PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE
EN 13229:2001 +A1:2003 +A:2004 CE
BK675
SPECIFIC Rev 03
JUL 2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stratford Ecoboiler and is the answer not in the manual?

Questions and answers

Summary of Contents for Arada Stratford Ecoboiler

  • Page 1 Ecoboiler Cassette Stove User Guide Ecoboiler Cassette PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE EN 13229:2001 +A1:2003 +A:2004 CE BK675 SPECIFIC Rev 03 JUL 2017...
  • Page 2 Should you have any questions about your stove which are not covered by this manual, please contact the Arada retailer in your area, call our technical support department on +44 (0)1297 35700 or visit our website www.aradastoves.com which offers a wealth of information on how to care for,...
  • Page 3: Table Of Contents

    ECOBOILER Cassette User Guide Contents 1 Identifying your stove 1.1 Identifying parts & terminology of your stove ………………….. 2 Warnings 2.1 General Warnings ………………………………………………… 2.2 Health and Safety ………………………………………………… 3 Advice on fuel types 3.1 Mineral smokeless fuel (Solid fuel)………………………………. 3.2 Other fuels…………………………………………………………..
  • Page 4 ECOBOILER Cassette User Guide 8 Further information for multi fuel stove owners 8.1 Multi fuel / Flexifuel grates ……………………………………... 9 How heat is delivered by your stove 9.1 Section through boiler stove ……………………………………. 9.2 Radiant heat ……………………………………………………… 9.3 Convected heat ………………………………………………….. 9.4 Hot water ………………………………………………………….
  • Page 5: Identifying Your Stove

    ECOBOILER Boiler User Guide 1 Identifying your stove 1.1 Identifying parts & terminology of your stove Top Flue Outlet (Hidden when installed) Water Connection Terminals (Hidden when installed) Hot Glove Operating Tool Both above items packed with stove Fire Door Handle Outer Trim May vary depending Main Fire Door...
  • Page 6: Warnings

    Any manufacturer’s instructions must not be taken as overriding statutory requirements. All Stratford Ecoboiler Cassette stoves MUST NOT be connected to a shared flue system. Please Note: Classification of these appliances is for intermittent use only. Do not use aerosol sprays or any other flammable materials near the appliance when in use.
  • Page 7: Health And Safety

    This will result in an over firing situation and will lead to severe damage to the stove and flue system. Ignoring the warnings could lead to damage/injury to persons and/or property. Arada Ltd will not be responsible for any consequential or incidental loss or injury however caused. 2.1 Health and Safety Please consult health and safety guidelines for advice on handling heavy and / or large items.
  • Page 8: Advice On Fuel Types

    Burn dry paper only or damage will occur to the flue or chimney with an increased risk of a chimney fire. DO NOT BURN any form of plastics in this appliance. For further advise on fuels, please contact your local retailer or Arada technical support. Page 8 BK 675 Specific...
  • Page 9: Before Using Your Stove

    Stratford stove. Always wear suitable protective fire gloves when refuelling your stove, such as the Arada hot gloves supplied with your stove. Always keep the hot glove away from naked flames and sparks, when re-fuelling the appliance.
  • Page 10: Air Inlet Controls

    ECOBOILER Cassette User Guide 5 Air inlet controls 5.1 Location and operation of the controls Your stove has two air inlet controls. These are located behind the drop down control door, located below the main fire door. To lower the control door there are two holes cut into the sides of the door panel, use these to pull open and lower the door.
  • Page 11: Primary Air / Thermostatic Control

    ECOBOILER Cassette User Guide 5.1.1 Primary air / Thermostat Control The primary air is supplied through the thermostatically controlled air inlet damper. This control will have been calibrated during production and it regulates the amount of under draught air entering the stove beneath the fire bed or grate bars. The control of the thermostatic damper is via a rotary knob, turning this knob clockwise raises the damper and therefore increases the amount of air entering the firebox.
  • Page 12: Lighting Your Stove

    ECOBOILER Cassette User Guide 6 Lighting your stove 6.1.1 Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke. Please see technical data section in this manual. 6.1.2 Operation with door left open Operation with the door open can cause excess smoke.
  • Page 13 ECOBOILER Cassette User Guide 3) After the kindling has caught light, you should almost close the fire door leaving it ajar by about 10mm. This will aid the flue draw during the initial lighting of the fire. 4) Once the flue draw has been established, after about five minutes, carefully load the stove with solid fuel and close the door.
  • Page 14: Initial Lighting Of Boiler Stove

    ECOBOILER Cassette User Guide 8) Locate the riddle lever (behind the control door on RH side of stove—see Fig. 4)) engage one of the forks of the operating tool into the rectangular hole within the riddle lever. Gradually pull in a linear motion until resistance is felt, then gradually push inwards until the stop is reached.
  • Page 15: Typical Solid Fuel Burn For Nominal Output

    ECOBOILER Cassette User Guide 6.4 Typical solid fuel burn for nominal output To perform the most efficient burn at the nominal rated output please consult the specification table at the rear of this manual. Please note, many factors can effect the nominal output, so the stated weights of fuel (Smokeless solid fuel briquettes) are a guide, which is a representation to laboratory burn conditions.
  • Page 16: Further Information For All Stove Owners

    Alternatively when the stove is cold, open the door and clean the inside face of the glass with a damp cloth or with glass cleaner (www.aradastovesandspares.com or Arada dealers). 7.2 Reduced burning Please note, during CE approvals the appliance has only been tested for nominal...
  • Page 17: Ash Removal

    ECOBOILER Cassette User Guide 7.5 Ash removal The ash pan should be emptied when the level of ash reaches the top of the ash pan. On no account should the ash be allowed to build up to touch the underside of the grate bars, as this will greatly reduce the life span of the grate.
  • Page 18: Replacement Parts

    It is worth noting that the fitting of non-official Arada parts to your stove will invalidate its guarantee. 8 Further information for multi fuel stove owners 8.1 Multi fuel / Flexifuel grates...
  • Page 19: Section Through Boiler Stove

    ECOBOILER Cassette User Guide 9 How heat is delivered by your stove 9.1 Section through boiler stove Radiant Heat From Top Products Of Combustion Boiler Water Jacket Radiant Heat Door & Surround Secondary Inlet Radiant Radiant Heat Heat From Rear Through Glass Primary...
  • Page 20: Radiant Heat

    ECOBOILER Cassette User Guide 9.2 Radiant heat All Stratford Ecoboiler Cassette stoves radiate heat into the room. The radiated heat is most intense at the front of the stove, especially through the door glass and less intense the further you move away from the stove.
  • Page 21: Adjusting The Door Hinges

    DO NOT operate the stove with cracked glass; this can lead to over firing due to air leaking into the firebox and it may fail completely leading to personal injury or a fire. Source a replacement glass kits from www.aradastovesandspares.com or your Arada dealer.
  • Page 22 ECOBOILER Cassette User Guide Access for cleaning should also be incorporated in the chimney (eg: soot door or access through the register plate etc). It is important that the flue connections, flue pipe and chimney be cleaned prior to lighting after a prolonged period of non use.
  • Page 23: Information

    ECOBOILER Cassette User Guide 11 Further resources / reading Once again we would like to thank you for buying your Stratford Ecoboiler Cassette stove. 11.1 Information We appreciate that we have given you a lot of information to read, but we hope it has been clear and helpful and that you are now able to enjoy the full benefits of your stove.
  • Page 24: Guarantee

    ECOBOILER Cassette User Guide 12 Guarantee When you buy an Arada stove, you are not only buying a first class appliance, you are receiving a commitment from us to look after you and your appliance. 12.1 Guarantee If any part of the main body of the stove fails due to a manufacturing or material defect during the guarantee period that applies in respect of the relevant stove (as set out below), Arada will, at its sole discretion, repair or replace your Arada stove, for no charge.
  • Page 25 11. The guarantee is only valid where any spare parts used are supplied by Arada or an approved Arada dealer. The use of spares other than those supplied by Arada Limited shall invalidate the guarantee.
  • Page 26: General

    ECOBOILER Cassette User Guide 12.3 General Our guarantee is offered as an addition to your statutory rights and will not effect your statutory rights. You can obtain information about your legal rights from trading standards office's or a citizens’ advice bureau. If you believe your appliance is not working correctly or it has broken down, in the first instance please contact your local retailer or installer for assistance.
  • Page 27: Technical Specification

    ECOBOILER Cassette User Guide 13 Technical specification Ecoboiler 12 TECHNICAL DATA Cassette Nominal Heat Output (Kw) 16.6 Nominal Heat Output To Space Efficiency Nett (%) Nominal Heat Output To Water 12.3 Efficiency Nett (%) Total Efficiency (Kw) 74.5 Mean Flue Gas Temperature (°C) Mean CO Emission @ 13% O2 (%) 0.28 Flue Mass Gas Flow (g/s)
  • Page 28 ECOBOILER Cassette User Guide Stratford is a brand name of Arada All Stratford ECOBOILER Cassette stoves are manufactured in the UK Arada Ltd Weycroft Avenue - Axminster - Devon EX13 5HU United Kingdom www.aradastoves.com T: +44 (0)1297 35700 info@aradastoves.com BK 675 Specific...

Table of Contents