Online Measurement; Achieving An Online Connection - Bosch DISBLAY DDU 7 Manual

Table of Contents

Advertisement

11 | Online Measurement

11.1
11.1.1
86 / 160
11
Online Measurement
DDU 7 configuration
▪ System configuration (channel + display configuration, CAN I/O, etc.) is stor‐
ed in the DDU 7
▪ Use RaceCon to create and download configuration from the PC to DDU 7
▪ Communication interface: Ethernet
▪ Communication protocol: XCP
Online measurement + calibration
▪ System status and diagnosis
▪ Check and calibrate sensors in the vehicle
▪ Live display of sensor values on the PC
▪ Use RaceCon for diagnosis, online measurement and calibration
▪ Communication interface: Ethernet
▪ Communication protocol: XCP

Achieving an online connection

Set up the PC for access to the Unit
1. Switch off local firewall on the PC.
2. Set IP Configuration for the Ethernet interface to 'automatic configuration'
(DHCP). See chapter 'Setting up the network interface
3. Start RaceCon.
4. Establish the Ethernet connection to the vehicle.
5. Power on the vehicle.
Yellow dot indicates
live connection to
the device, but local
RaceCon configu-
ration does not match
DDU 7
the
's
configuration
Click 'OK' to
download RaceCon
configuration
to device
Status message
below
DDU 7 Manual
[}
15]' for details.