Design
The LK Minishunt M60 is intended for use in
smaller under floor heating areas (up to 60 m² de-
pending on heating requirements/laying proce-
dures etc.) and is connected to an existing heating
system. The shunt unit consists of an automatic
speed-controlled circulation pump for the under
floor heating circuit, a maximum limit function
for the feed temperature, a return valve for the
under floor heating circuit, a fill/discharge and
air bleed valve plus a thermostatic valve unit, fit-
ted with a thermostat and a sensor, connected to
a capillary tube.
Connectors for a under floor heating circuit and
mini manifolds for 2, 3 or 4 under floor heating
circuits are provided as accessories. Possible pipe
connections for floor heating are dim. 8, 12, 16
and 20 mm. The installation can be concealed in
built-in or wall-mounted cabinets, see heading
Installation cabinets.
1. Thermostat valve.
2. Switching between single or twin pipe
radiator systems and shutting-off against
the return connection of the primary side.
When delivered, the minishunt is set for a
twin pipe radiator system with the outer
hex-screw spindle (dim. 10 mm hex.) scre-
wed in and the inner hex-screw spindle
(dim. 4 mm hex.) screwed out. For single
pipe systems the outer hex-screw spindle is
gradually screwed out until correct
9
10
6 14
temperature is achieved to the radiators.
Shutting-off against the return connection
of the primary side is achieved by turning
closed the outer and then the inner hex-
screw spindle.
3. Thermostat with capillary tube connected
sensor, length 2 m.
4. Feed connection from the primary side, ¾"
male EuroCone. Connectors for 15 mm Cu
are supplied.
5. Return connection to the primary side, ¾"
male EuroCone. Connectors for 15 mm Cu
are supplied.
6. Temperature limiter. Maximum limiter of
the feed temperature to the under floor
heating.
7. Return valve (dim. 8 mm hex.).
8. Connection ½" female thread for system
refill upon installation.
9. Ventilation valve with hose nipple.
10. VF valve (dim. 8 mm hex.). Must only be
used for installations with low available
drive pressure from the circulation pump of
the primary side.
11. Circulation pump, Wilo Yonos Para
RSB15/6-RKA with automatic speed con-
trol.
12. Connection feed floor heating ½" female
thread.
13. Connection return floor heating ½" female
thread.
14. Bracket
Assembly instructions | LK Minishunt M60
11
12
13
EN.33.C.134.1512
1 (8)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Minishunt M60 and is the answer not in the manual?

Questions and answers

Summary of Contents for LK Systems Minishunt M60

  • Page 1 6 14 Design temperature is achieved to the radiators. The LK Minishunt M60 is intended for use in Shutting-off against the return connection smaller under floor heating areas (up to 60 m² de- of the primary side is achieved by turning...
  • Page 2: Function & Requirements

    Assembly The LK Minishunt M60 must be mounted at a hig- her level than the under floor heating installation in order to assist air bleeding. Pay attention to any structure-borne noise from the minishunt when placing it.
  • Page 3 To install the supplied thermostat with capillary Wireless or wired electronic room control for tube connected sensor, dismantle the hand actua- LK Minishunt M60 are available as accessories. tor and the black threaded adapter according to The enclosed thermostat with capillary tube con- the sequence below.
  • Page 4 See heading Circulation pump. Adjustment As the LK Minishunt M60 is intended for con- LK Minishunt M60 assembled in LK Cabinet M60 WP. nection to existing heating systems, the availa- ble drive pressure and flow on the primary side Article no.
  • Page 5: Circulation Pump

    Assembly instructions | LK Minishunt M60 2. Start the pump. Upon start up, use the auto- Setting of the temperature limiter for the feed temperature matic venting routine to remove accumula- of the under floor heating. ted air in the pump. The automatic venting Dial settings from open Max.
  • Page 6: Capacity Chart

    Capacity chart [kPa] p - c Q [m³/h] 0,025 0,05 0,075 0,10 0,125 0,15 0,17 0,20 0,225 0,25 0,275 Q [l/s] Capacity chart LK Minishunt M60 with Wilo Yonos Para RSB 15/6-RKA. EN.33.C.134.1512 6 (8)
  • Page 7: Troubleshooting

    AV/RV The radiators after the minishunt do not get warm for the single pipe radiator systems Primary side The LK Minishunt M60 is supplied in the twin with master pipe design. For the single pipe system, switching pump Secondary side...
  • Page 8 Assembly instructions | LK Minishunt M60 Dimensions Dimension sketch for the LK Under Floor Heating with Minishunt M60 The table is based on a heat output of approx. 50 W/m² and an indoor temperature of 20 °C. The primary temperature is calculated at 55 °C and with a floor temperature at approx. 40/33 °C. Under floor heating systems 1-7 respectively 10-13 are calculated using 14 mm laminated parquet.

Table of Contents