Kinder Fires KF 130T User Instructions

Kinder Fires KF 130T User Instructions

Oasis rc & hls decorative coal effect gas fire

Advertisement

Quick Links

Kinder Fires
Oasis RC
HLS
&
Model No. KF 130T
KF 140T
DECORATIVE COAL EFFECT GAS FIRE
These instructions
should be read by the user before operating the appliance and retained
for future reference
This appliance is only for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.BI
I.E.
57832

Advertisement

loading
Need help?

Need help?

Do you have a question about the KF 130T and is the answer not in the manual?

Questions and answers

Summary of Contents for Kinder Fires KF 130T

  • Page 1 Kinder Fires Oasis RC & Model No. KF 130T KF 140T DECORATIVE COAL EFFECT GAS FIRE These instructions should be read by the user before operating the appliance and retained for future reference This appliance is only for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.BI I.E.
  • Page 2 It is the law that all gas appliances are installed only by a competent (e.g. CORGI Registered) Installer, in accordance with the installation instructions and the Gas Safety (Installation and Use) Regulations 1994 as amended. Failure to install appliances correctly could lead to prosecution. is in your own interest and that of safety to comply with the law.
  • Page 3 The Kinder Oasis fuel effect gas fire incorporates a unique and highly developed fuel bed which gives the realism of a loose coal layout combined with realistic flames and glow. The use of durable hard ceramic material in the construction of the fuel bed components ensures long and trouble free operation.
  • Page 4 WARNING This appliance has a naked flame and as with all heating appliances a fireguard should be used for the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards for use with solid fuel appliances). Servicing should be carried out annually by a competent person such as a CORGI registered engineer.
  • Page 5 There are two types of control for the fire, a high level switch and a hand held remote control unit (KF130T). There is also an aeration lever (situated behind the ash pan cover) which slides from left to right. The left hand position gives maximum radiant heat and output whereas the right hand position gives more flame but slightly less glow.
  • Page 6 sensor will control the point at which the fire regulates between the high and low settings, but the point at which the appliance switches between high and low is dependent upon many factors such as room temperature, the time the appliance has been running, flue performance etc.
  • Page 7 and cover (if supplied with the fire) are solid brass and may be cleaned using a suitable proprietary metal polish. If you purchased an alternative fender from your supplier it is important to find out whether it is lacquered before cleaning it. In this case, your supplier will be able to advise you on the best cleaning method.
  • Page 8: Re-Assembling The Fuel Bed

    RE-ASSEMBLING THE FUEL BED Place the insulation mat centrally on to the fuel bed base plate support then place the ribbed hard ceramic fuel bed base on top of the mat and pull both fully forwards to the burner. Make sure that the fuel bed base is located centrally in the firebox.
  • Page 9 b) Place both the hard ceramic fuel bed sections on to the base so that the location lugs fit snugly into the recesses on the fuel bed sections. Place the Front Ceramic Rail centrally onto the Semi-Circular location plate situated at the front of the burner.
  • Page 10 Select four of the large coals and two small coals, and place them on the front of the fuel bed directly behind the spaces between the front row of coals. Place the remaining four large coals as shown below (Taking care not to allow the coals to be trapped behind the fuelbed):- 57832...
  • Page 11 The exact position and fit of the coals may be finely adjusted to give the most pleasing and random appearance. Warning: Use only the coals supplied with the fire. When replacing the coals remove the old coals and discard them. Fit a complete set of coals of the correct type. Do not fit additional coals or any coals other than a genuine replacement set.
  • Page 12 This fire has a degree of built in fault diagnosis. The main purpose would be to allow the customer to report the exact problem before the visit from a service engineer. Various fault conditions can be detected and indicated by means of the bar graph display.
  • Page 13 The only user replaceable parts on this fire are the fuel bed components and coals which may be replaced as described in the above section. Replacement of any other parts must be carried out by a competent person such as a CORGI registered gas installer. The part numbers of the user replaceable parts are as follows, these are available from Kinder...