6-13 ERROR MESSAGE
NO
CHECKING
Restart the machine
1
service call
Refer to [6-14 SERVICE
CALL]
Restart the machine
2
Internal Error
Upgrade the firmware to
the latest version
6-14 SERVICE CALL
CONTENTS
CODE
Disorder of communication with Sub CPU
This occurs when the Sub CPU is not
0002
detected after turning on the machine
0004
Sub CPU SRAM error
An error occurs while downloading a
program for sub CPU.
0005
An error occurs when trying to connect with
sub CPU.
0006
An error occurs while sending a command.
0007
There is a problem with synchronizing serial
communication to Sub CPU.
0008
Network I/F Initialize has not been
0010
completed.
Limit Position Initialize in the Service Mode
has not been done.
0101
Even though the machine carries out the
0102
regular movement, the output of Head Lock
Sensor does not reach the expected value.
Even though the machine carries out the
0103
regular movement, the output of Limit Sensor
does not reach the expected value.
Tool Carriage Connection Error
0105
Machine fails to disconnect the Tool
Carriage from the Head Carriage.
0106
Linear Encoder Setup has not been done.
0107
ACTION
[6-14 SERVICE CALL]
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
SRAM is broken.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
A noise on a signal while sending a
command.
Sub CPU was reset to default.
Tried to communicate when Sub CPU was
reset to default.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal while sending a
command.
Sub CPU was reset while sending a
command.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
Network I/F does not work correctly.
Firmware for Network I/F is not installed.
Limit Position Initialize has not been done.
Limit Position Initialize is ended before it is
completed.
Head Lock Sensor does not work correctly or
is broken.
Limit Sensor does not work correctly or is
broken.
Fault of Tool Carriage Connection
Loose of Connection Part
Fault of the Limit Position Initialize value
Limit Sensor does not work correctly or is
broken.
Fault of Tool Carriage Connection
Loose of Connection Part
Fault of the Limit Position Initialize value
Limit Sensor does not work correctly or is
broken.
Linear Encoder Setup has not been done.
Linear Encoder Setup is ended before it is
completed.
REFERENCE
Restart the machine and see if the same error occurs again.
Restart the machine and see if the same error occurs again.
Check the revision record of the firmware version and
upgrade it if the error has been solved in the firmware.
CAUSE
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
Servo Board replacement
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
Check the firmware is installed into Network I/F.
Main Board replacement
Complete Limit Position Initialize correctly.
Head Lock Sensor replacement
Check the mechanical backlash or loose with the scan axis
related parts.
Limit Sensor replacement
Check the mechanical backlash or loose with the scan axis
related parts.
Check the mechanical Backlash or loose with the Tool
Carriage part.
Connection Part Replacement
Limit Position Initialize
Check the mechanical Backlash or loose with the Tool
Carriage part.
Connection Part Replacement
Limit Position Initialize
Carry out Linear Encoder Setup in service menu.