Download Print this page

Chronomite M-40 Installation And Operation Instructions

Instant-flow micro water heaters

Advertisement

Quick Links

CHRONOMITE INSTANT-FLOW MICRO WATER HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS (STANDARD MODELS)
Instant-Flow Micro
• Dimensions:
• Weight:
• Materials:
• Color:
• Pipe Fittings:
• Pressure Requirements:
• Maximum Operating Temp:
• Minimum Operating Flow Rate: .65 GPM
* Minimum Operating Flow Rate: 1.0gpm for Models
M-40-220/240, M-40/277 & M-50-220/240
• Listings:
THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES
DUE TO THE FAILURE TO FOLLOW THESE INSTALLATION AND OPERATION INSTRUCTIONS.
CAUTION:
BEFORE BEGINNING THE INSTALLATION:
A)
Turn off the circuit breaker to avoid dangerous electrical shocks.
B)
Turn off the water supply.
1. Remove electrical access cover. Attach conduit to the conduit access hole. Then feed wires. Do not attach wiring.
2. Mount unit horizontally against the wall so the silver label reads correctly (See Fig. 1). Mount with four screws
through the flanges located on each corner using molly anchors or fasteners.
CAUTION: Heating elements may burn out if not mounted horizontally.
3. Connect plumbing. Use
compression fittings supplied for ease of installation. Do not apply heat to these fittings.
4. Run water through the unit to expel all air bubbles. Check for leaks at all fitting joints.
5. Connect wiring. Attach ground wire to center terminal and hot wires to outer terminals (See Fig. 3).
6. Replace electrical access cover. Turn on the circuit breaker. The unit is now ready for use.
7. Local plumbing and electrical codes must be followed in the installation of this water heater and it's accessories.
8. Failure to comply with code requirements voids the warranty.
Downloaded from www.GadgetsGo.com, Authorized Chronomite Distributor
(Before installation, compare electrical needed for the model of heater selected)
Model No.
M-30
M-30
M-30
M-40
M-40
M-40
M-50
6 ¼ " x 9
x 2 ¾
5/8 "
5 lbs.
Rugged cast aluminum alloy casing, Celcon waterways with nichrome parts
White (unless stainless steel housing)
Female
NPT standard pipe thread
¼"
25 PSI Minimum 150 PSI Maximum (300 PSI tested) No pressure relief valve needed
unless required by local codes.
140°F
UL, HUD, IAPMO
tapered national pipe thread at cold water inlet and hot water outlet (See Fig. 1). Use
¼"
TABLE 1
Wattage
Voltage
Breaker
Size
6240
208
30A
7200
220/240
30A
8310
277
30A
8320
208
40A
9600
220/240
40A
11080
277
40A
11520
220/240
50A
"
Specifications:

Advertisement

loading
Need help?

Need help?

Do you have a question about the M-40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chronomite M-40

  • Page 1 6. Replace electrical access cover. Turn on the circuit breaker. The unit is now ready for use. 7. Local plumbing and electrical codes must be followed in the installation of this water heater and it’s accessories. 8. Failure to comply with code requirements voids the warranty. Downloaded from www.GadgetsGo.com, Authorized Chronomite Distributor...
  • Page 2: Important Notes

    Copper or flex tubing 3/8” OD, 5” long (keep short) Copper or flex tubing 3/8” OD, length as required (keep short) A-212 Faucet flow control (supplied) dual thread 15/16” male thread 55/64” female thread (See Downloaded from www.GadgetsGo.com, Authorized Chronomite Distributor...
  • Page 3 Figure 2) adapters if needed Note:C=Copper Cup MP=Male Pipe FP=female Pipe STD=Thread Comp=Compression Fittings page 2 OPERATION INSTRUCTIONS Turn the hot water fixture to activate the flow switch. The flow switch activates at one gallon per minute (GPM) and deactivates at .65 gallon per minute. If you increase the flow rate of the water will become cooler.
  • Page 4: Troubleshooting Guide

    (1) year from the date of purchase. The above warranty applies to original purchaser if unit is installed to Chronomite Laboratories, Inc.’s Installation Instructions. Chronomite Laboratories, Inc. will repair or exchange parts at the factory at no cost. This warranty is limited to repairing or replacing said products which...
  • Page 5 Chronomite Laboratories Inc. 17451 Hurley Street. City of Industry, CA 91744 Toll Free Technical Hotline 800-447-4962 Telephone 626-937-4270 Fax 626-937-4279 #928 02/05 rev.7 page 4 Downloaded from www.GadgetsGo.com, Authorized Chronomite Distributor...

This manual is also suitable for: