1-3. Connectors and Cables

1-3. Connectors and Cables

1-3-1. Connector Input/Output Signals

TEST OUT
BNC 75 Z 1.0 V p-p
PROMPTER
BNC 75 Z 1.0 V p-p
TRIAX
King type (for BVP-900)
Fischer type (for BVP-900P)
TRACKER (10P FEMALE)
7
6
(EXTERNAL VIEW)
No.
SIGNAL
1
TRACKER R OUT (X)
2
TRACKER T IN (G)
3
TRACKER R OUT (G)
4
PGM OUT (X)
5
+12 V (T) OUT
6
PGM OUT (G)
7
TRACKER T IN (X)
8
TRACKER T IN (Y)
9
UP TALLY OUT (G)
10
UP TALLY OUT (X)
1-2 (E)
8
1
2
10
9
3
5
4
SPECIFICATIONS
TRACKER RECEIVE
0 dBu unbalanced
GND for TRACKER T
GND for TRACKER R
_20 dBu unbalanced
+12 V dc, 100 mA (MAX)
GND for PGM
TRACKER TALK
0 dBu/_20 dBu
High impedance balanced
GND for UP TALLY
+12 V dc, 200 mA ( MAX)
(0 dBu = 0.775 Vrms)
RET CONTROL (6P FEMALE)
(EXTERNAL VIEW)
No.
SIGNAL
1
INCOM 1
MIC ON/OFF IN
2
INCOM 2
MIC ON/OFF IN
3
GND
4
RET 3 ON/OFF IN
5
RET 1 ON/OFF IN
6
RET 2 ON/OFF IN
*1
DC OUT 12 V
(4P FEMALE)
(EXTERNAL VIEW)
No.
SIGNAL
1
GND
2
NC
3
NC
4
+12 V OUT
*1: In connection with BVF-7700/7700P, the DC OUT 12 V connector and
REMOTE connector cannot be used together, because of a limit of
power supply capacity.
SPECIFICATIONS
Zi > 10 kZ
ON: GND
OFF: OPEN
Zi > 10 kZ
ON: GND
OFF: OPEN
Zi > 10 kZ
ON: GND
OFF: OPEN
Zi > 10 kZ
ON: GND
OFF: OPEN
Zi > 10 kZ
ON: GND
OFF: OPEN
4
1
3
2
SPECIFICATIONS
GND for POWER
No connection
No connection
+12 V dc, 0.5 A (MAX)