Page 1
OWNER’S MANUAL & OPERATING INSTRUCTIONS 9375 Starting Watts/7500 Running Watts Wireless Remote, Electric Start PORTABLE GENERATOR MODEL NUMBER 100161 12039 Smith Ave. SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 Important safety instructions USA / 1-877-338-0999 MADE IN CHINA are included in this manual.
Page 2
FCC Statement for Remote Control Device 1. This device complies with Part 15 of the FCC Rules. accordance with the instructions, may cause harmful Operation is subject to the following two conditions: interference to radio communications. However, there (1) This device may not cause harmful interference. is no guarantee that interference will not occur in a (2) This device must accept any interference particular installation.
Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
100161 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death. DANGER CAUTION DANGER indicates an imminently hazardous...
100161 ENGLISH SAFETy RULES WARNING DANGER Generator produces powerful voltage. Read this manual thoroughly before operating your generator. Failure to follow instructions could result DO NOT touch bare wires or receptacles. in serious injury or death. DO NOT use electrical cords that are worn, damaged or frayed.
Page 7
100161 ENGLISH SAFETy RULES DANGER WARNING Fuel and fuel vapors are highly flammable and Rapid retraction of the starter cord will pull hand and extremely explosive. arm towards the engine faster than you can let go. Fire or explosion can cause severe burns or death. Unintentional startup can result in entanglement, Unintentional startup can result in entanglement, traumatic amputation or laceration.
SAFETy RULES Safety Label Locations These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Champion Power Equipment’s customer service department for possible replacement. WARNING...
100161 ENGLISH CONTROLS AND FEATURES Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator Fuel Tank – 6.1 gal. (23 L) capacity fuel tank. Recoil Starter –...
100161 ENGLISH CONTROLS AND FEATURES Power Panel Battery Switch – Enables/disables starting 120/240 Volt AC / 50 Amp Receptacle electrically – via remotely or by Ignition Switch. (NEMA 14-50R) – May be used to supply electrical power for the operation of 120 and/or 240 Volt 120/240 Volt AC, 30 Amp Twist-Lock Receptacle AC, single phase 60 Hz electrical loads.
(6) times. The RCM controls the Auto Choke during each attempt to start. If the generator does not start, call Champion Customer Care team for assistance at 1-877-338-0999. To stop the generator by Remote Control, press the “STOP”...
100161 ENGLISH CONTROLS AND FEATURES Parts Included Your 100161 Gasoline Powered Generator ships with the following parts: Wheel Kit – 10 in. (25.4 cm) Wheel ....–...
100161 ENGLISH ASSEMBLy Install the Support Leg Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced 1. Attach the support leg to the generator frame with with fuel and oil before operation. flange bolt (M8x16) and flange lock nuts (M8).
100161 ENGLISH ASSEMBLy Add Engine Oil Add Engine Oil Cont’d. CAUTION NOTE Check oil often during the break-in period. Refer to the DO NOT attempt to crank or start the engine before Maintenance section for recommended service intervals. it has been properly filled with the recommended type and amount of oil.
100161 ENGLISH ASSEMBLy Add Fuel Add Fuel Cont’d. 1. Use clean, fresh, regular unleaded fuel with a NOTE minimum octane rating of 85 and an ethanol content of less than 10% by volume. Our engines work well with 10% or less ethanol 2.
100161 ENGLISH OPERATION Generator Location Grounding NEVER operate the generator inside any building, The generator system ground connects the frame to the including garages, basements, crawlspaces and sheds, ground terminals on the power panel. The system ground is enclosure or compartment, including the generator connected to the AC neutral wire.
100161 ENGLISH OPERATION Wireless Remote and Electric Start Recoil Start Wireless remote starting is only possible within 80 feet 1. Make certain the generator is on a flat, level surface. of the generator. 2. Turn off all electrical loads connected to the Do not attempt to adjust the carburetor choke.
100161 ENGLISH OPERATION Connecting Electrical Loads Stopping the engine Cont’d. 1. Let the engine stabilize and warm up for a few NOTE minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC Always turn the battery switch to the “OFF” position when unit is not in use, this will stop the single phase, 60 Hz electrical loads.
To alleviate high altitude issues other than the natural power loss, Champion Power Equipment can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting Customer Support.
100161 ENGLISH MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic Oil Cont’d. maintenance. NOTE WARNING Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. Never operate a damaged or defective generator. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking.
Service your generator more frequently when operating with the three screws. in adverse conditions. Contact our helpline at 1-877-338-0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs. Every 8 hours or daily Check oil level...
100161 ENGLISH MAINTENANCE AND STORAGE Generator Maintenance Storage Make certain that the generator is kept clean and stored The generator should be started at least once every properly. Only operate the unit on a flat, level surface in 14 days and allowed to run for at least 20 minutes. For a clean, dry operating environment.
100161 ENGLISH MAINTENANCE AND STORAGE Generator Battery Disconnect the Battery 1. Remove the protective cover from the black/negative This product is equipped with an automatic battery battery lead. charging circuit. The battery will receive charging 2. Disconnect the black/negative lead from the black/ voltage when the engine is running.
100161 ENGLISH Parts List Part Number Description Part Number Description 2.06.006 Clamp, Ø7 x Ø1 1.862.06 Lock Washer Ø6, Toothed 1.5789.0612 Flange Bolt M6 x 12 152.070013.03 Pipe, Air Cleaner, 135 mm 5.1900.026 Grounding Line 150 mm 2.06.004 Clamp, Ø8 x Ø1 152.201200.04 Motor Mount 2 2.05.001...
100161 ENGLISH Part Number Description Part Number Description 21.061300.00 Recoil Handle 47.020100.00 Bolt, Cylinder Head Cover 2.08.039 Bolt, Drain, M12 x 1.5 x 15 1.5789.0608 Flange Bolt M6 x 8 47.041000.01 Camshaft 46.061100.00.2 Recoil Starter Cover, Black 47.040004.00 Lifter, Valve 45.060005.00 Recoil Starter Spring 47.040002.00...
100161 ENGLISH TROUBLESHOOTING Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Generator will not start; Low oil level Fill crankcase to the proper level Generator starts but runs roughly Place generator on a flat, level surface Choke in the wrong position...
Warranty Registration Card and a copy of your sales – Problems caused by parts that are not original Champion Power receipt from one of CPE’s retail locations as proof of purchase. Equipment parts.
Page 32
The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emission regulations.
Page 33
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 34
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.
Need help?
Do you have a question about the 9375 and is the answer not in the manual?
Questions and answers
Where is the oil drain tube located on the 9375
Spark plug size