Download Print this page

Socket & See PDL 310 User Manual

Part p multifunction digital loop tester tests no-trip loop, pfc, socket, mains voltage & polarity

Advertisement

Quick Links

U S E R
M A N U A L
0 6 / 0 6
PART P MULTIFUNCTION DIGITAL LOOP TESTER
Tests no-trip loop, PFC, socket, mains voltage & polarity
PDL 310

Advertisement

loading
Need help?

Need help?

Do you have a question about the PDL 310 and is the answer not in the manual?

Questions and answers

Summary of Contents for Socket & See PDL 310

  • Page 1 U S E R M A N U A L 0 6 / 0 6 PART P MULTIFUNCTION DIGITAL LOOP TESTER Tests no-trip loop, PFC, socket, mains voltage & polarity PDL 310...
  • Page 2 If there is any aspect of your Socket & See tester you would like to comment on please visit our website at www.socketandsee.co.uk or email davidh@kewt.co.uk or Free Fax at 0800 7831385 with any suggestions. We promise all communications will be acknowledged. We value YOUR opinion. PDL 310...
  • Page 3: Operation Overview

    Operation overview Your Socket & See tester has a special polarity test function. It is a little known fact that a system can be reverse wired with Live (Phase) to earth/neutral and earth/neutral to Live (Phase) The sockets will all work and conventional loop testers will show and test that everything is correct despite this very dangerous wiring condition.
  • Page 4 Operation overview continued The PDL 310 is a multifunction tester testing for no trip loop, no-trip PFC (Prospective Fault Current), mains voltage (L-N), correct socket wiring, and polarity. Correct socket wiring and correct polarity At the Socket Test stage the PDL 310 also accurately measures and displays the mains voltage in the LCD (Liquid Crystal Display).
  • Page 5 Operation - a detailed view of the PDL 310 Note numbers also indicate sequence of test. Three LED’s show socket wiring status LCD (Liquid Crystal Display) display (default L-N voltage measurement) On/off button (Prospective Fault Current Result) 5/6. Test push...
  • Page 6: Overview Of The Display

    C. HANDSFREE operation D. Ohms symbol Volts (AC) (L-N) Fault current G. Wait - result calculation in progress H. Tester has gone over operating temperature Greater than (>) less than (<) indication Battery Condition ( =good) PDL 310...
  • Page 7 Loop-PFC testing Plug the tester in and switch on the mains supply. Power ON/OFF - Pressing and releasing this button turns the PDL 310 on - holding down for longer than two seconds turns the unit off (plus intelligent Auto Power Off is incorporated).
  • Page 8: Specifications

    Weight ............400g PDL 310...
  • Page 9 Socket Test Technology The PDL 310 uses our well proven Socket Testing patented technology to indicate the socket is correctly wired. Plugging the unit in and switching on mains supply automatically initiates the socket test sequence. If the socket is correctly wired the LED’s will be GREEN on this check.
  • Page 10 PDL 310...
  • Page 11 Socket & See Industrial www.socketandsee.co.uk Unit 4, Century Road, High Carr Business Park, Newcastle, Sta ordshire, UK, ST5 7UG T +44 (0)1782 567096 F +44 (0)1782 567095 © Socket & See Limited (A division of the Kew Technik Group of companies)
  • Page 12 Condition Wiring Supply Buzzer Number Condition Terminal Display Socket Wiring Correct Continuous L-E reverse Warble L-N-E miswire Warble L-N reverse Warble L-N-E miswire Warble Faulty N / L-E miswire Warble Faulty N / E miswire Warble Faulty N Warble Faulty N / L-E reverse Warble Faulty E / L-N reverse Warble...