Shorting Door Lock Circuit Contactor Feedback; First Fire Emergency Signal; Overload Signal; Full-Load Signal - Monarch NICE1000 User Manual

Integrated elevator
Table of Contents

Advertisement

NICE1000
new
User Manual
under the effect of the weighing difference between the car and the counterweight.
This function can also be used at normal elevator stop to improve safety.

08: Shorting door lock circuit contactor feedback

It is used to short or release the door lock circuit if the function of door pre-open upon arrival
or re-leveling at door open is enabled for the elevator configured with the pre-open module.
09: Inspection signal
When the Automatic/Inspection switch is set to the Inspection position, the elevator enters
the inspection state; in this case, the system cancels all automatic running including the
automatic door operations. When the inspection up signal or inspection down signal is valid,
the elevator runs at the inspection speed.

12: First fire emergency signal

When the first fire emergency switch is turned on, the elevator enters the fire emergency
state, and immediately cancels the registered hall calls and car calls. The elevator stops at
the nearest floor without opening the door, and then directly runs to the fire emergency floor
and automatically opens the door after arrival.
13: Reserved
When the elevator lock signal is active, the system enters the elevator lock state.
15: Up limit signal
16: Down limit signal
The up limit signal and down limit signal are used as the stop switches at the terminal floor
to prevent over travel top terminal or over travel bottom terminal when the elevator runs over
the leveling position of the terminal floor but does not stop.
17: Up slow-down signal
These signals are set to NO input, corresponding to the slow-down switches. The system
automatically records the positions of the switches in group F3 during shaft auto-tuning.

19: Overload signal

When the elevator load exceeds 110% of the rated load during normal use, the elevator
enters the overload state. Then the overload buzzer beeps, the overload indicator in the car
becomes ON, and the elevator door keeps open.
The overload signal becomes invalid when the door lock is applied. If the running with
110% of the rated load is required during inspection, you can set Bit2 of F6-10 to 1 to allow
overload running (note that this function has potential safety risks and use it with caution).

20: Full-load signal

When the elevator load is 80% to 110% of the rated load, the hall display board displays the
full-load state, and the elevator does not respond to hall calls.
21: Emergency stop (safety feedback) signal
The safety circuit is important to guarantee safe running of the elevator.
22: Door 1 open limit signal
The terminal with this function is used to receive the corresponding door open limit signal.
10: Inspection up signal
14: Elevator lock signal
18: Down slow-down signal
23: Door 2 open limit signal
- 121 -
Description of Function Codes
11: Inspection down signal

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NICE1000 and is the answer not in the manual?

Questions and answers

Brijesh Kumar
February 23, 2025

Monarch 1000 main only 4th floor ka level kese set kare

1 comments:
Mr. Anderson
February 23, 2025

To set the 4th floor level on the Monarch NICE1000 main unit, follow these steps:

1. Enter the leveling adjustment mode by pressing the top floor button and bottom floor button in the car simultaneously.
2. Once in leveling mode, press the door close button and select the 4th-floor button.
3. The elevator will move to the 4th floor and keep the door open.
4. Adjust the leveling position as needed.
5. Repeat the process for other floors if necessary.
6. After completing all adjustments, set parameter Fr-00 to 0 to disable the leveling adjustment function. This step is essential; otherwise, the elevator cannot be used.

This process ensures that the 4th-floor leveling position is correctly set.

This answer is automatically generated