1. SPECIFICATIONS: QW-2367 Item Detail Battery CTL1616 (Storage battery) Note: Use CTL1616 only. Other storage battery or CR1616 can cause damage to the watch. Battery life Approx. 6 month (from full charged condition) 0.548 µA maximum Current consumption Alarm system Piezo plate on Cover/Back ±15 sec./month Accuracy...
2. OPERATION CHART: QW-2367 General Guide · Press C to change from mode to mode. Telememo Mode Alarm Mode · In any mode, press B to illuminate the display. Day Counter Mode Timekeeping Mode Press C. Hand Setting Mode Stopwatch Mode Timekeeping Use the Timekeeping Mode to set and view the current time and date.
Page 5
Auto Summer Time (DST) Switching About Auto Receive The time calibration signal transmitted from Mainflingen, Germany includes When auto receive is turned on, the watch automatically starts to receive the both standard time and summer time (Daylight Saving Time or DST) data. time calibration signal when the digital time in the Timekeeping Mode reaches Because of this, the watch automatically switches between standard time and 2:00 AM, and 4:00 AM each day (calibration times).
Page 6
4. When the setting you want to change is selected, use B and D to change When you want to do this: Perform this button operation: · Press B. Move the hand setting · Selecting the text causes the text input cursor to appear. back 20 seconds ·...
Page 7
3. Press B and D at the same time to delete the record. your dealer or CASIO distributor about having the rechargeable battery · The message “CLEAR” appears for a few moments, and then the cursor replaced.
Page 8
Reference This section contains more detailed and technical information about watch Inputting Text operation. It also contains important precautions and notes about the various The following describes how to input text in the Day Counter and Telememo features and functions of this watch. Modes.
4. As for order/supply of spare parts, refer to the separate publication "GUIDE BOOK for spare parts supply". Item Code No. Parts Name Specification Applicable 1006 5039 MODULE/WITH MOVEMENT QW-2367YCSA-01 WVA-300D-1A1/1A2 WVA-300K-1A 1006 5656 LCD C2368-01 QW-2367YCSA-01 1006 5665 EL YEL-2368-A-01 QW-2367YCSA-01...
6. PRECAUTIONS FOR REPAIR: QW-2367 6-1. AC (ALL CLEAR) AND REMOVING OF MODULE 1. Perform AC (ALL CLEAR) when inserting a new battery, or else the memories and/ or counters may give erratic displays. Touch the AC contact and the positive (+) side of the battery or main plate with the metallic tweezers. The contact should be made for about two seconds.
7. TROUBLESHOOTING: QW-2367 This is a flow chart about signal reception. START Check whether the Home City code is selected correctly. To perform MANUAL time calibration signal reception (See page 3 of this manual). Signal reception OK? To perform AUTO time calibration signal reception (See page 3 of this manual).