Environmental requirements
Storage
Environmental conditions - Enclosure
Ingress protection rating
Temperature range:
Operating (with a maximum temperature gradation of
15°C per hour)
Non-operating (with a maximum temperature gradation
of 15°C per hour)
Relative humidity (maximum):
Operating (with maximum humidity gradation of 10%
per hour)
Non-operating (with maximum humidity gradation of
10% per hour)
Altitude (maximum, unpressurized):
Operating
Storage
Operating conditions
Maximum vibration
Operational
Maximum shock
Operational
Non-operational
68
-15.20 m to 10,668 m (-50 ft to 35,000 ft)
IP65
•
Edge Gateway 5000: 0°C to 45°C (32°F to 113°F)
•
Edge Gateway 5100: -30°C to 70°C (-22°F to 158°F)
-40°C to 85°C (-40°F to 185 °F)
10% to 90% (non-condensing)
5% to 95% (non-condensing)
-15.2 m to 5000 m (-50 ft to 16,404 ft)
-15.2 m to 10,668 m (-50 ft to 35,000 ft)
5000
1.54 Grms, 15 min/side
5000
40G, 2ms
160g, 2ms Half Sine Shock
NOTE: The maximum operating temperature is derated
1°C/305m (1000ft) above sea level altitude.
NOTE: Require IP65 or above conduit connection.
NOTE: The maximum operating temperature is derated
1°C/305 m (1000 ft) above sea level altitude.
NOTE: The maximum operating temperature is derated
18°C (32.4°F) under direct solar thermal load.
NOTE: The maximum operating temperature is derated
1°C/305 m (1000 ft) above sea level altitude.
5100
1.54 Grms, 60 min/side
5100
40G, 2ms
160g, 2ms Half Sine Shock