5.1. Alarm codes
COOL FIRE
In the event of an even very short lack of current, the stove switches off.
As soon as the power supply is back, the stove will start a cooling cycle and the display will show the
words "Cool fire". After completing the cooling cycle, the stove will start up again.
NOTE: If your stove is supplied with a remote control and there is a lack of current, remember to pro-
gram the eventual switching on and off times again. In the event of a lack of current, the stove will loose
any previous time settings.
Once the power supply is back, press the key SEND on the remote control to retransmit
the automatic programming you previously set to the stove.
SERV
The signal "Serv" on the display means that the stove has reached 900 hours working. Please con-
tact an authorised technical service to arrange a supplementary maintenance.
ALARM NO ACC: FAILED LIGHT UP
This alarm occurs when the time foreseen for a light up (around 15 minutes) passes and the smokes
temperature is still too low. This can occur also when there is not enough pellets flow to light up the
unit. Press the key On/Off on the control board to reset the alarm. Wait until the cooling phase is
completed, clean the brazier and start up with a new switching on.
ALARM NO FIRE
This alarm occurs in the event the stove switches off during its working phase (for example if there is
no pellets left in the pellets tank). You will read the words "Alarm No fire" on the display. Press the
key On/Off on the control board to reset the alarm. Wait until the cooling phase is completed, clean
the brazier and start up with a new switching on.
ALARM FAN FAIL
This alarm occurs in the event the smokes ejector is broken or the pcb cannot detect the speed of the
smokes exhaust fan. In this case press the key On/Off to reset the alarm and contact the technical
assistance.
ALARM SOND FUMI
This alarm occurs in the event the sensor for smokes temperature is broken or not connected. You will
read the words Alarm Son fumi on the display. In this case press the key On/Off to reset the alarm
and contact the technical assistance.
ALARM DEP SIC FAIL
This alarm is signalised by the Leds ALF and ALC blinking on the control board.
It indicates two different possibilities: an obstruction in the flue or a possible overheating of the stove.
In both cases the motor reducer to load the endless screw stops working and the stove switches off.
Press the key On/Off to reset the alarm. Check the possible activation of the manual reset thermostat
on the back of the stove (4). Unscrew the safety cap and press the key.
In the event you have the same problem more than once, please contact the technical assistance.
4
1
2
3
1. Lighting button
2. Fuse F4AL250V
3. Thermostat reset button
4. Environmental probe