Troubleshooting No Power to the Console, P10 and P30
This troubleshooting is for Standard, P10 or P30 consoles only. The P80 uses its own
power source separate from the Motor Controller.
1. Using an AC voltmeter, verify that the outlet voltage is appropriate. See procedure,
Troubleshooting Tripped Breakers
If NO, advise customer to have their facility wiring upgraded per Precor specifications
and then continue with troubleshooting.
If YES, continue with the following steps.
2. Remove the treadmill hood and measure the AC voltage at the input side of the line filter with
a voltmeter. Verify that line voltage is present when the breaker switch is turned on.
If NO, Replace the breaker switch.
If YES, continue with the following steps.
3. Measure the AC voltage at the output side of the line filter with a voltmeter. Verify that line
voltage is present when the breaker switch is turned on.
If NO, Replace the line filter.
If YES, continue with the following steps.
4. Use a known good console and communication cable. Plug the test console and test
communications cable into the suspect treadmill Control Module. Does the test console
power up?
If NO, Replace the Control Module.
If YES, continue with the following steps.
5. If the test console did power up in step 4, re-connect the test communications cable from the
test console to the original console. Does the original console power up?
If YES, Replace the Communications Cable.
If No, troubleshoot the console assembly.