12.8 in
(325mm)
(325mm)
PC/ABS
©2013 AIRIUS, LLC
10, 15 and 25. All voltages and colors.
12.8 in
(325mm)
SHORT
AIRIUS, LLC (Manufacturer)
Longmont, Colorado 80501 - USA
Toll free: 1-888-Air-Pear (247-7327)
Telephone: 303-772-2633
Email: info@theairpear.com
Web: www.theairpear.com
AIRIUS Europe Ltd. (Exclusive Importer)
2 Longham Business Centre
168 Ringwood Road, Ferndown, Dorset
BH22 9BU – United Kingdom
Telephone: +44 (0) 1202 554200
Fax: +44 (0) 1202 554396
Email: airflow@airius.co.uk
AIRIUS Pty Ltd. (Exclusive Importer)
Telephone: +61 2 8084 8524
Email: info@airius.com.au
ALL RIGHTS RESERVED
811 South Sherman St.
Fax: 303-772-8276
Web: www.airius.co.uk
P/O Box 6282
Alexandria NSW 2015
V1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air Pear 15

  • Page 1 INSTALLATION & OPERATING GUIDE FOR MODELS 10, 15 AND 25 Air Pear Model Numbers: 10, 15 and 25. All voltages and colors. 12.8 in (325mm) (325mm) 12.8 in (325mm) SHORT STANDARD Installation Guide: V1.1 AIRIUS, LLC (Manufacturer) 811 South Sherman St.
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION Thank You About Models 10, 15 and 25 What’s in the Box Motor & Housing Information Safety Precautions PRE-INSTALLATION Preparing the Work Site Tools Needed Fan Diagram Understanding Air Pear Air Flow INSTALLATION Power Requirements Plug Wiring Speed Control Wiring Suggested Installation Methods Suspended Ceiling Kit Assembly &...
  • Page 3: Thank You

    About Models 10, 15 and 25 The Air Pear unit is an energy efficient air turbine, designed to continuously move a column of air to the floor for destratification and air circulation purposes. A typical Air Pear system installation includes a series of units mounted just below the ceiling, evenly spaced throughout a facility, working in concert to improve comfort and reduce HVAC energy consumption up to 35% or more*.
  • Page 4: Motor & Housing Information

    Motor & Housing Information for Models 10, 15 & 25 STANDARD HOUSING Weight..............................9 lb (4.1 kg) Height to Rim............................16 in (410 mm) Total Height............................22 in (560 mm) Diameter.............................13 in (330 mm) SHORT HOUSING Weight..............................7 lb (3.2 kg) Height to Rim............................12 in (305 mm) Total Height............................16 in (410 mm)
  • Page 5: Safety Precautions

    Contact Airius for additional information regarding variable speed controls and options. Do not carry the Air Pear unit by the cord. Do not use the cord as a handle. Do not use the cord to attach or hang the product.
  • Page 6 #2 Phillips screwdriver. The Air Pear unit is designed to be used with only the electrical voltage identified on the label located in the nozzle and on the bottom of the motor. Connecting to any other voltage could damage the motor and create an electrical hazard and will void warranty.
  • Page 7: Preparing The Work Site

    Air Pear model 10, 15 or 25 fans use very little amperage (less than 1 amp) thus multiple outlets may be installed on one circuit.
  • Page 8: Tools Needed

    GROUNDING MACHINE SCREW x 1 EA. UNMARKED = HOT 13) STATOR (ABS) 14) STRAIN RELIEF 15) 3 WIRE 6FT 300 VAC RATED POWER CORD - POWER CO 1 EA. (SPECIFY PLUG AND/OR VOLTAGE) WIRE COLOR CODES: BLACK or BROWN - HOT/ELECTRIFIED WHITE or BLUE - “N”...
  • Page 9: Understanding Air Pear Air Flow

    Understanding Air Pear’s Unique Air Flow Low Velocity Intake - Low intake speed does not disturb air boundary layer under roof deck. Columnar Laminar Flow - Removing the rotational component induced by the axial fan allows for the air to move in a straight, ductless column from the ceiling to the floor.
  • Page 10: Power Requirements

    If you have questions contact your local electrical contractor. Branch Circuit Protection The Air Pear fans do not include fuses for branch circuit protection. The branch circuit must have a dedicated circuit breaker or similar device. National and local safety standards and electrical codes may determine additional requirements for installation.
  • Page 11: Plug Wiring

    Air Pear system. NOTE: The Air Pear System can be wired directly to a junction box but only by a qualified electrician or similarly qualified person. Always ensure that all relevant local regulations/electrical codes are understood and followed with care - if in any doubt seek expert guidance.
  • Page 12: Speed Control Wiring

    Speed Control Wiring SAFETY WARNING! CONNECTION DIAGRAM FOR 2-WIRE CONTROLS Unit should be installed by a qualified electrician in accordance with the National Electrical Code and other local codes which may apply. This control must be grounded when installed. Failure to follow these instruc- tions may result in electrical shock or a fire hazard.
  • Page 13: Suggested Installation Methods

    Suggested Installation Methods A feature of the Air Pear system is its flexibility. Hardware that may be used to hang the unit includes, but is not restricted to: Hooks, chains, cables, carabiners, bridle rings, beam clamps and bolts. Roof structure, building construction and accessibility will define the appropriate hardware for each installation.
  • Page 14 10/15/25, capable of supporting a minimum of five times the weight of the Air Pear unit, 60 lb (27 kg). Example - 1/4” (7 mm) diameter steel bolt is rated at 60 lb (27 kg) load.
  • Page 15 Suggested Installation Methods After ensuring the Air Pear system is firmly attached, remove your hands from the unit. It is then safe to plug the unit into the power source using the approved plug to confirm function and electrical continuity.
  • Page 16: Suspended Ceiling Kit Assembly & Installation

    J-box Mounting Location Right Angle Tabs *Included in hardware bag Remove the Air Pear from its box and plastic protective bag. The bail (handle) is attached via two Torx screws. Loosen these screws and remove the bail (discard at your discretion).
  • Page 17 Suspended Ceiling Kit Assembly & Installation (cont.) Place dome over Air Pear unit and align it with screw holes. Note that cutout should face the j-box mounting location. Dome should seat into the rim designed for it on the base, if necessary gently push the dome edge in until it seats inboard of the rim.
  • Page 18 Suspended Ceiling Kit Assembly & Installation (cont.) Plug the Air Pear power cord into the receptacle. Using the supplied thumbscrews, fasten the j-box to the air intake grill through the indicated holes as shown (wiring to j-box omitted for clarity).
  • Page 19: Heating Season

    The Air Pear is an energy efficient air turbine, designed to continuously move a column of air to the floor. A typical Air Pear installation includes a series of units mounted just below the ceiling, evenly spaced throughout a facility, working in concert to balance the air temperature ceiling to floor and wall to wall.
  • Page 20: Preventive Maintenance

    General Troubleshooting The Air Pear units are tested before they leave the factory, resulting in an extremely low rate of returns. However, mechanical devices do fail and we recommend that you identify the problem and try the simple suggestions below.
  • Page 21: Airius Warranty Policy

    Airius warrants products listed below will operate properly and be free of defects in materials and workmanship according to the following terms: Products Warranty Period Air Pear Fans 3 Years (All Parts/Components) Designer Series Fans 3 Years (All Parts/Components) Suspended Ceiling kit...
  • Page 22: Acquiring Warranty Service

    Airius Warranty Policy (Continued) Failure to perform periodic maintenance as detailed in the Airius-supplied “Installation Guide.” Consequential or incidental damages sustained by any person or entity as a result of any breach of these warranties are also excluded, except where such damages may not be excluded by law. Acquiring Warranty Service Do not return any item without first being assigned a Return Material Authorization (RMA) tag number.
  • Page 23 Airius Contact Information Airius Americas: AIRIUS, LLC (Manufacturer) 811 South Sherman St. Longmont, Colorado 80501 - USA Toll free: 1-888-Air-Pear (247-7327) Telephone: 303-772-2633 Fax: 303-772-8276 Email: info@theairpear.com Web: www.theairpear.com Airius Europe: AIRIUS Europe Ltd. (Exclusive Importer) 2 Longham Business Centre 168 Ringwood Road, Ferndown, Dorset BH22 9BU –...