Braeburn 5020 Installer Manual

Braeburn 5020 Installer Manual

Premier series
Hide thumbs Also See for 5020:

Advertisement

Installer Manual

Programmable Thermostats

5020 Single Stage Conventional Systems
or Single Stage Heat Pumps with Auxiliary Heat
5220 Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Model number is located on back of thermostat.
1 Specifications
4 Installer Settings
Warning
For installation by experienced service technicians only.
Caution
• Possible electric shock or damage to equipment can occur.
• Disconnect power before beginning installation.
This thermostat requires 24 Volt AC Power or 2 properly installed "AA" Alkaline batteries for
proper operation. When connecting 24 Volt AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
Visit www.braeburnonline.com for detailed Installer Guide.
1 Specifications
This thermostat is compatible with:
• Single stage heat / cool conventional and heat pump systems
• Single stage heat pumps with auxiliary heat
• Conventional systems up to 2 stages of heating and 2 stages of cooling (5220 only)
• Heat pump systems up to 3 stages of heating and 2 stages of cooling (5220 only)
• 250 – 750 millivolt heating only systems
• 2 or 3 wire hydronic zone systems
Electrical and control specifications:
• Electrical Rating: 24 Volt AC
• 1 amp maximum load per terminal
• AC Power: 18 – 30 Volts AC
• DC Power: 3.0 Volt DC
(2 "AA" Alkaline Batteries Included)
• Control Range: 45° – 90° F (7° – 32° C)
• Temperature Accuracy: +/- 1° F (+/- .5° C)
• Outdoor Temperature Display Range: -40° - 120° F (-40° - 49° C)
2 Installation and Wiring
®
3 Quick Reference
5 System Testing
Terminations
• 5020: Rc, Rh, W1/E, C, Y1, O/B/V3, G, S2, S1
• 5220: Rc, Rh, W2, W1/E/W3, C, L, Y2, Y1,
O/B/V3, G, S2, S1
P
REMIER
S
ERIES
5020-100-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5020 and is the answer not in the manual?

Questions and answers

Robert Henry Guillemette
April 18, 2025

can I use non-programable only?

Summary of Contents for Braeburn 5020

  • Page 1: Programmable Thermostats

    • 2 or 3 wire hydronic zone systems Terminations Electrical and control specifications: • 5020: Rc, Rh, W1/E, C, Y1, O/B/V3, G, S2, S1 • Electrical Rating: 24 Volt AC • 5220: Rc, Rh, W2, W1/E/W3, C, L, Y2, Y1, •...
  • Page 2: Installation And Wiring

    Installation and Wiring Install your new Braeburn thermostat in 4 basic steps: 1 Install the sub-base 3 Connect your wires 2 Provide Power 4 Attach the thermostat to the sub-base Install the Sub-Base: Provide Power • Remove the sub-base from the body of the thermostat.
  • Page 3 Connecting Your Wires (continued) Wiring Terminations for model 5220 Terminal Function Description Input 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) Input Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) Output Fan Control W1 / E / W3 Output (W1) 1st Stage Conventional Heat, (E) Emergency Heat,...
  • Page 4: Conventional Systems

    Conventional Systems Typical Wiring Configurations NOTE: The “System Type” option will be configured in the Installer Settings section. Shaded areas do not apply to the 5020. Heat Only or Millivolt 1 HEAT / 1 COOL Single or Dual Transformer Set System Type to 11CONV...
  • Page 5: Heat Pump Systems

    Heat Pump Systems - Typical Wiring Configurations NOTE: The “System Type” option will be configured in the Installer Settings. Shaded areas do not apply to 5020. 1 HEAT / 1 COOL - No Auxiliary Heat 2 HEAT / 2 COOL - No Auxiliary Heat...
  • Page 6: Attach Thermostat To Sub-Base

    NOTE: Additional options are configured in the NOTES - Additional Wiring Options Installer Settings section. [1] These terminals can be used to connect a Braeburn indoor or outdoor remote sensor. ® Indoor or Outdoor Remote Sensor [note 1] Attach Thermostat to Sub-Base...
  • Page 7: Quick Reference

    Quick Reference Instructions ..Stored in slot located at top of thermostat SpeedBar ........Increases or decreases settings (time, temperature, etc.) ® Outdoor Temperature ...... If a Braeburn outdoor sensor was connected you can view the outdoor ® temperature by pressing the PROG and HOLD buttons at the same time.
  • Page 8: Installer Settings

    RETURN to exit. BACK NEXT BACK NEXT DAY/TIME DAY/TIME NOTE: Shaded areas below do not apply to the 5020. No. Installer Setting Factory Setting Comments Default Options Notes follow this table) (More information follows this table)
  • Page 9 No. Installer Setting Factory Setting Comments Default Options Notes follow this table) (More information follows this table) 0.5 DIF1 0.5, 1.0 or 1st Stage Differential Select a 1st stage temperature differential of 2.0 DIF1 .5°, 1° or 2° F (0.2°, 0.5° or 1.0° C) 2.0 DIF2 1.0, 2.0, 3.0, 2nd Stage Differential...
  • Page 10 ® 10 Only available if auto changeover was enabled in option 5. 11 Only available if a Braeburn outdoor sensor was connected. Detailed Explanation of Installer Settings (also see NOTES above): Profile – Selects a residential (RES) or commercial (COMM) profile. If residential is selected, 4 programming events per day are available.
  • Page 11 (I SENS), remote sensor only (E SENS) or combining the thermostat and the remote sensor (A SENS). NOTE: This option does not apply to a Braeburn outdoor sensor. When an outdoor sensor is connected the thermostat automatically recognizes it and no further configuration is necessary.
  • Page 12: System Testing

    22 Auto Changeover Dead Band [note 10] – When auto changeover mode is enabled in option 5 and selected, the system automatically switches between heating and cooling when the room temperature meets the normal criteria for either a heating or cooling call. There is a forced separation (dead band) between the heating and cooling set points so that the systems do not work against each other.
  • Page 13: Limited Warranty

    Store this manual for future reference. ® Braeburn Systems LLC 2215 Cornell Avenue • Montgomery, IL 60538 Technical Assistance: www.braeburnonline.com Call us toll-free: 866-268-5599 (U.S.) 630-844-1968 (Outside the U.S.) 5020-100-04 ©2016 Braeburn Systems LLC • All Rights Reserved • Made in China.
  • Page 14 Notes...

This manual is also suitable for:

5220

Table of Contents

Save PDF