Maintenance
9. Install the remaining parts onto the bearing shaft as follows (see the illustration):
10. Install the shaft assembly into the bearing frame as follows (see the illustration):
Assemble the rotating element and the bearing frame (XLT-i and
i17 with duplex bearings)
WARNING:
Lifting and handling heavy equipment or components poses a crush hazard. Use caution
during lifting and handling and wear appropriate Personal Protective Equipment (PPE, such as
steel-toed shoes, gloves, etc.) at all times. Seek assistance if necessary.
114
a) Install a new O-ring (496).
b) Install the outboard labyrinth oil-seal (332A) into the end cover (109A).
Place the drain slots of the oil seal at the bottom position (6 o'clock).
Make sure that the edges of the keyway are free from burrs. To protect the O-ring,
cover the keyway lengthwise with a piece of electrical tape before you install the oil
seal.
a) Coat the outside of the bearing housing (134) with oil.
b) Coat all the internal surfaces of the bearing frame (228) with oil.
c) Install the shaft assembly into the bearing frame (228).
Make sure that the shaft rotates freely.
d) Install the clamp bolts (370C) in the bearing housing (134) and tighten by hand.
e) Install the jack bolts (370D) with the locknuts (423) in the bearing housing (134) and
tighten by hand.
f)
Attach the bearing-frame foot (241) and fasten the bolts (370F) by hand.