Aeon Labs MultiSensor 6 User Manual

Aeon Labs MultiSensor 6 User Manual

Z-wave multisensor

Advertisement

Quick Links

Aeon Labs MultiSensor 6
(Z-wave MultiSensor)

Advertisement

loading
Need help?

Need help?

Do you have a question about the MultiSensor 6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aeon Labs MultiSensor 6

  • Page 1 Aeon Labs MultiSensor 6 (Z-wave MultiSensor)
  • Page 2 Change history Revision Date Change Description 9/23/2014 Initial draft. 5/26/2015 Update 7/01/2015 Update 7/21/2015 Update (V1.06) 8/11/2015 Add more details for configuration parameters...
  • Page 3 Aeon Labs MultiSensor 6 Engineering Specifications and Advanced Functions for Developers Aeon Labs MultiSensor is a routing binary sensor device based on Z-Wave routing slave library V6.51.06. MultiSensor can be included and operated in any Z-wave network with other Z-wave certified devices from other manufacturers and/or other applications.
  • Page 4: Technical Specifications

    Security COMMAND_CLASS_ZWAVEPLUS_INFO, Command COMMAND_CLASS_VERSION, Supported Report COMMAND_CLASS_MANUFACTURER_SPECIFIC, Frame COMMAND_CLASS_WAKE_UP, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_NOTIFICATION_V3, COMMAND_CLASS_BATTERY, COMMAND_CLASS_SENSOR_BINARY, COMMAND_CLASS_SENSOR_MULTILEVEL_V5, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_SECURITY, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 2. Technical Specifications Operating distance: Up to 500 feet/150 metres outdoors. Operating temperature: 0 ℃ 40 . ℃ Relative humidity: 8%RH to 80%RH. 3.
  • Page 5 3. Remove MultiSensor from Z-wave network: 1. Power on MultiSensor. The MultiSensor’s LED will be kept turning on for 8 seconds when you short press the Action Button. 2. Let the primary controller into exclusion mode (If you don’t know how to do this, refer to its manual). 3.
  • Page 6 5.2 Association Command Class MultiSensor supports 1 association group. Group 1 is assigned to the Lifeline association group and can add max 5 association nodes. When the PIR motion sensor is triggered, the MultiSensor will send Basic Set (0xFF) to the associated nodes.
  • Page 7 Parameter Description Default Value Size Number Hex / Decimal 2 (0x02) Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 1. Value = 0, disable. 2. Value =others, enable. 3 (0x03) 1. The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes.
  • Page 8 43 (0x2B) Threshold change in luminance to induce an automatic report. 100 (LUX) 44 (0x2C) Threshold change in battery level to induce an automatic report. 10 (%) Note: The unit is %. The default value is 10, which means that if the current battery level gap is more than 10%, it will send out a battery report.
  • Page 9 113 (0x71) The interval time of sending reports in Report group 3 (Valid values 0x05- 3600 (seconds) 0x28DE80). 1. The unit of interval time is second if USB power. 2. If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes.
  • Page 10 configuration Reserved Value 1(MSB) configuration Reserved Value 2 configuration Reserved Value 3 configuration Value 4(LSB) Luminance Humidity Temperature Ultraviolet Reserved Reserved Reserved Battery Reserved Reserved bits or bytes must be set to zero.