Index INDEX CERTIFICATE OF CONFORMITY US Regulatory Wireless Notice European Union Notice COPYRIGHT NOTICE WELCOME Key Features Power and Control QUICK START HOW TO PLAY Contacts Surface Electrodes Connection Cables Electrode Positioning Do’s and Don’ts FITTING A BATTERY EXTERNAL POWER SUPPLY USER CONTROLS Overview Channel Level Controls...
Page 3
DIGITAL LINK Bootloader GETTING MORE ACCESSORIES ADDITIONAL NOTES Storage Cleaning QUICK GUIDE TO MODES SPECIFICATIONS PROBLEMS?
The FCC requires the user to be notified that any changes or modifications made to the device that are not expressly approved by E-Stim Systems Ltd may void the users authority to operate the equipment. European Union Notice...
• Power and Control As well as offering all the interesting modes like pulse, tickle and squeeze, the 2B will run in two different power levels. ‘L’ (for LOW power) is the default setting and is ideal for those people who are just starting out on their E-Stim experience, whilst the ‘H’ high power setting takes the 2B unit into a whole new realm of serious power output.
Make sure you have nothing else attached to the unit. The LCD should light up, and text appears. If the LCD illuminates, but no text appears then you many need to adjust the contrast.(page 11). Once your 2B has started up you should see a display similar to This shows the unit is in Pulse mode, with both outputs set to OFF, output power is set to low, and the pulse rate and pulse feel are both set to 50.
Page 7
Not powerful enough? The 2B operates in two modes LOW Power and High Power. See page 14 for details on how to switch your 2B box to the high power level. And if you want even more power, then connect our external power supply unit.
You may feel more sensation in one location than the other. This is the nature of e-stim and is normal - Just try moving things around and experiment with positions to find what works for you.
Fitting a battery The 2B is powered by a single 9V battery. Unlike some other units it is also possible to use rechargeable batteries in the 2B control unit. We do NOT recommend the use of Zinc Carbon batteries with your 2B control unit.
User Controls Overview The 2B unit has five user controls. Each control allows the user to adjust a particular aspect of the output. It is the operation of the controls in combination that will allow the user to provide an effective electro-stimulation session.
Joining Controls (A+B Mode) When you first switch your 2B unit on, both the Channel A and Channel B controls are independent. However If you select the join mode (A+B) then the two controls become linked, giving you effectively one handed operation.
USB cable. DO NOT attempt to attach any other USB cable to the 2B digital link input, you will destroy your 2B and invalidate your guarantee. DO NOT attempt to connect an output to an input. It will destroy your 2B unit, and possibly the item you connect to.
Modes The 2B has two sets of modes. Program modes offer variations on output and are of most interest to the user. System Modes control the general operation of the 2B. Selecting a Mode If you need to shutdown the...
The battery level indicator shows the current level of the battery. There are 3 battery level symbols, indicating FULL, 2/3 full, 1/3 full and empty. As the 2B uses a 9V battery, a brand new battery should show full, however the unit will continue to operate with ‘flat’...
Factory Reset A number of settings are retained when your 2B unit is switched off. To clear these settings select the factory reset option. Commander ÿ Commander™ is our PC/Mac control system for the 2B. in conjunction with our Digital link interface you can control the functions of the 2B directly from your PC.
Program Modes The 2B offers a number of program modes. Each mode is designed to offer something different, but all are controlled by the rotary controls on the front panel. Pulse Mode In pulse mode both of the outputs pulse on and off together. The adjustment control allows the user to adjust the pulse rate (how quickly they pulse on and off) and is adjustable from 2 to 100.
Wave Mode The output level increases from 0% to the selected limit and then drops back to 0% The adjustment control controls how fast the level goes up or down, with values from 2 to 100. The second value, is the pulse feel, that allows you to adjust the sensation of the pulse stream, from soft to spiky, with values from 1 to 100.
Throb Mode A continuous mode with the pulse feel cycling between 10 and the adjustment value. Nice and relaxing. Adjustments values are between 10 and 100. Thrust Mode Similar to Throb, Thrust is a continuous mode. with the pulse feel cycling between 10 and the adjustment value and then back to 0.
Training Mode The training mode is similar to the Step Mode (page 18), but the steps are much bigger, requiring the subject to learn to ‘enjoy’ each step before the output is stepped up to the next level. The output steps between 0 and the current Channel level. Each step is 1/12 of the total Channel level or 1% if the channel level is set to 12% or lower, so if Channel A is set to 48%, the steps will be 4%, 8%, 12% up to 48%, and then dropping to zero.
You should aim for maximum movement in the bar graph. If the bar graphs are ‘full’ you should reduce the output volume of the device you are driving the 2B with, if there appears to be no bar graph then turn the volume control up.
Firmware upgrades are not included as part of your lifetime guarantee. Getting More If you want to find out how to get the best of out your 2B, we have a dedicated E-Stim Systems Forum at http://www.e-stim.net Share your ideas with other 2B users.
Additional Notes Storage In the event that the 2B™ unit is not going to be used for a period of time always remove the battery to avoid any possibility of damage being caused by battery leakage. Cleaning Do NOT use solvents to clean your 2B™. A gentle wipe with a soft cloth should be...
Quick Guide to Modes Mode Diagram Adjustment Select+Adjustment Notes Both channels pulse on Pulse Pulse speed Pulse Feel and off Channels pulse Bounce Pulse speed Pulse Feel alternately. Channels are on Continuous Pulse Feel continuously The Split channel pulse, A Split Pulse speed Pulse Feel the other channel is on...
Output Waveform Biphasic AC Audio Inputs Stereo 33KΩ 1 off Standard 9 Volt Alkaline (PP3) Power Supply or Optional E-Stim Systems Power Supply Battery Life Variable dependent on load. Dimensions (approx.) 145mm x 80mm x 50mm Weight (with battery) 400g 2 off 3.5mm to 2mm/TENS output cables,...
Our lifetime guarantee does not affect your statuary rights. SAFETY WARNING (DO NOT CONNECT THE E-Stim Systems 2B UNIT OR ANY ELECTRICAL DEVICE TO ANY LOCATION ABOVE THE WAIST (ACROSS THE ARMS COUNTS AS ABOVE THE WAIST!), BUT ESPECIALLY DO NOT CONNECT ACROSS THE HEART, CHEST, NECK OR HEAD.
Need help?
Do you have a question about the 2B and is the answer not in the manual?
Questions and answers