    Room actuator 230 V Ref.-no.: RA 23024 REGHE Operating instructions Room actuator 230 V Table of contents Safety instructions Device layout Function System Information Designated use Operation Controls Status indication Modes of operation Blind/shutter control priorities Fitting and electrical connection Installing the device Connecting the device Connecting switched loads...
  • Page 2: Safety Instructions

    (7) connecting terminals for 230 V valve drives Function System Information This device is a product of the KNX system and complies with KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. The functionality of this device depends on the software.
  • Page 3: Designated Use

    Room actuator 230 V Ref.-no.: RA 23024 REGHE commissioning software from version ETS3.0d onwards. The product database, technical descriptions, conversion programs and other utilities are available in their latest version on our Internet page. Designated use • Switching of electrical consumers AC 230 V with potential-free contacts •...
  • Page 4: Operation

    Room actuator 230 V Ref.-no.: RA 23024 REGHE Operation Controls Fig.2: Controls – layout output status LEDs : Manual control (10) : permanent manual control indicator (11) key ON/ : switching on or opening a valve or raising a curtain / stop (12) LED ON/ : lit up: switched on or blind/shutter moving upwards, manual control mode...
  • Page 5: Blind/Shutter Control Priorities

    Room actuator 230 V Ref.-no.: RA 23024 REGHE After failure and return of mains voltage, the device switches over to bus operation. Manual control mode can be disabled in operation via bus telegram. Blind/shutter control priorities • Highest priority: manual control •...
  • Page 6 Room actuator 230 V Ref.-no.: RA 23024 REGHE over to the position active at the time of deactivation of the manual control mode, e.g. to forcing or logic operation. Shutter outputs: Depending on programming, the blinds/shutters move to the position active at the time of deactivation of the manual control mode, e.g.
  • Page 7: Fitting And Electrical Connection

    Room actuator 230 V Ref.-no.: RA 23024 REGHE flashing twice briefly at intervals. Re-enabling the outputs The device must in the permanent manual control mode. • Press the key briefly, < 1 sseveral times until the desired output is selected. The status LEDs of the selected outputs A1...A6 flashes twice briefly at intervals.
  • Page 8: Connecting The Device

    Room actuator 230 V Ref.-no.: RA 23024 REGHE Connecting the device Fig.3: Connection • Connect the bus line to the bus terminal. • Connect the mains voltage supply. • Connect the loads as described in the following chapters. Delivery state: provisional operation possible, output control via keypad enabled, All outputs are configured as shutter outputs.
  • Page 9: Connecting 230 V Valve Drives

    Room actuator 230 V Ref.-no.: RA 23024 REGHE Fig. 5: Connection of blind/shutter motors Observe the permissible load ratings (Technical data). The output must have been parameterized as switching output. Caution! Risk of irreparable damage if several drives are connected in parallel to one output.
  • Page 10: Start-Up

    • Switch on the mains voltage at the outputs. Appendix Technical data KNX-medium Commissioning mode S-mode KNX supply 21...32 V DC KNX power consumption max. 150 mW Rated voltage AC 230 / 240 V~ Mains frequency 50/60 Hz Heat dissipation max. 6 W Ambient temperature -5 °C...+45 °C...
  • Page 11 Room actuator 230 V Ref.-no.: RA 23024 REGHE Connecting cross-section Single-wire 0.5...4 mm² stranded wire without ferrule 0.35...4 mm² stranded wire with ferrule 0.14...2.5 mm² Heating outputs Contact type semiconductor, ε Switching voltage AC 230/240 V Switching current 5 mA … 50 mA Inrush current max.
  • Page 12: Help In Case Of Trouble

    Room actuator 230 V Ref.-no.: RA 23024 REGHE Help in case of trouble Manual control with keypad not possible Manual operation not parameterized. Parameterize manual operation. Manual operation disabled via the bus. Enable the manual control mode. No mains voltage. Switch on the mains voltage.
  • Page 13: 10 Guarantee

    Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55 .