Page 1
V28™ POWER Lithium-Ion Charger & Battery Pack Troubleshooting Guide 8. Connector Block The following V28™ POWER Lithium-Ion Charger & Battery Pack Troubleshooting Guide used in conjunction with a ‘new-from-stock ● known good’ 48-11-2830 28V Lithium-Ion Battery Pack and 48-59-2801 28V Lithium-Ion Charger will allow for initial troubleshooting of a customers V28 Battery Pack and/or Charger.
Page 2
— V28 ™ POWER LITHIUM-ION CHARGER TROUBLESHOOTING GUIDE — Symptom Possible Cause(s) Solution(s) Line voltage too high or too low (or no power present) Remove Battery Pack. Unplug Charger and verify correct line voltage (90VAC – Battery Pack 132VAC for 120V units, 200VAC – 255VAC for 230V units; inverter power at levels connected to higher than 230V may cause this condition.
Page 3
— V28 ™ POWER LITHIUM-ION BATTERY PACK TROUBLESHOOTING GUIDE — Symptom Possible Cause(s) Solution(s) Battery Pack temperature is below 14ºF or between This is normal. Charger is waiting for Battery Pack temperature to reach acceptable Battery Pack range for charging. Charge will commence once temperature reaches proper range.
Page 4
If it's rechargeable, it's recyclable! A depleted, used up, worn–out, faulty or defective 48-11-2830 28V Lithium-Ion Battery and not being returned to Milwaukee Pack should be recycled using the RBRC consolidation centers in the USA and Canada. For additional information on...