Power Supply
FD1-11
230Vac±10%,
50/60Hz, Operating 3.2W, Standby 0.9W
Relay Output
Compressor - 16(8) A 240Vac
Defrost - 16(4) A 240Vac
Evap. Fan - 16(4) A 240Vac
Auxiliary Loads 1 - 8(2) A 240Vac
Input
NTC 10KΩ@25°C
Parameters should not be changed unless you have an understanding of their purpose and
the following instructions are fully understood.
To gain access to the parameters use the 'Adjustment Mode'. This is accessed by pressing
and releasing the
for 5 seconds. The first parameter will show on the display.
Using the
and
If you wish to change a parameter value press and release the
desired mnemonic. Once selected in this way use the
the new reuired value is shown it will be saved by pressing and relaeasing the
After which the display will show the next parameter.
To exit this mode or revert to normal operating mode, press
release.
If at any point no buttons are pressed for 30 seconds without saving a new value the display will
return to the standard temperature display without changes being made.
switch. After selecting this mode press and hold
switches you can scroll through all parameters and their values.
Measurement Range
-50...120°C, -55...240°F
-50 / -9.9...19.9 / 80°C (NTC 10K Only)
Measurement Accuracy
<0.5°C within the measurement range
CE (Reference norms)
EN60730-1; EN60730-2-9
EN55022 (Class B)
EN50082-1
and
switches to modify. When
and
and
together
switch when one the
switch.
together then
6