Please read the “Warning/Caution Information” on the attached sheet before using the product. Overview Package Contents..................4 About the Manual...................5 Global Code ....................5 Electrical Specifications 1. PFXGP4301TADR/PFXGP4401TADR ............6 2. PFXGP4501TADR/PFXGP4601TADR ............7 Part Numbers and Functions 1. PFXGP4301TADR ..................8 2. PFXGP4401TADR ..................9 3. PFXGP4501TADR ..................10 4. PFXGP4601TADR ..................11 5.
Overview Package Contents The following items are included in the package. Before using the GP unit, please confirm that all items listed here are present: GP unit: 1 DC power supply connector: 1 USB cable clamp Type A: 1 set (1 clip and 1 tie) Installation gasket: 1 set (8 per set) Installation fasteners: 2 per set (attached to the top and bottom surfaces of the GP unit)
You can download the manual from our website at http://www.pro-face.com/trans/en/manual/1001.html Global Code A global code is assigned to every Pro-face product as a universal model number. For more information on product models and their matching global codes, please refer to the following URL.
Electrical Specifications 1. PFXGP4301TADR/PFXGP4401TADR Specification PFXGP4301TADR PFXGP4401TADR Rated Input Voltage 24 Vdc Input Voltage Limits 19.2...28.8 Vdc Voltage Drop 5 ms or less Power Consumption 10.5 W or less 12 W or less When power is not 6.5 W or less...
Electrical Specifications 2. PFXGP4501TADR/PFXGP4601TADR Rated Input Voltage 24 Vdc Input Voltage Limits 19.2...28.8 Vdc Voltage Drop 10 ms or less Power Consumption 17 W or less When power is not 12 W or less supplied to external devices Backlight OFF 7 W or less (Standby Mode) Backlight Dimmed...
Part Numbers and Functions 1. PFXGP4301TADR Right Rear Bottom A: USB (Type A) Interface B: Serial Interface (COM1) C: Serial Interface (COM2) D: Power Plug Connector E: SD Card Access LED (see page.13) F: SD Card Interface Cover/Replacement Battery Insertion Cover G: USB (mini-B) Interface H: Ethernet Interface (see page.13) Maintenance LED (see page.
Part Numbers and Functions 2. PFXGP4401TADR Right Rear Bottom A: USB (Type A) Interface B: Serial Interface (COM1) C: Serial Interface (COM2) D: Power Plug Connector E: SD Card Access LED (see page.13) F: SD Card Interface Cover/Replacement Battery Insertion Cover G: USB (mini-B) Interface H: Ethernet Interface (see page.13)
Part Numbers and Functions 3. PFXGP4501TADR Rear Bottom A: Power Plug Connector B: SD Card Access LED (see page.13) C: SD Card Interface Cover/Replacement Battery Insertion Cover D: USB (mini-B) Interface E: Ethernet Interface (see page.13) F: Maintenance LED (see page.12) G: USB (Type A) Interface H: Serial Interface (COM1) Serial Interface (COM2)
Part Numbers and Functions 4. PFXGP4601TADR Rear Bottom A: Power Plug Connector B: SD Card Access LED (see page.13) C: SD Card Interface Cover/Replacement Battery Insertion Cover D: USB (mini-B) Interface E: Ethernet Interface (see page.13) F: Maintenance LED (see page.12) G: USB (Type A) Interface H: Serial Interface (COM1) Serial Interface (COM2)
Part Numbers and Functions 5. LED Indications (1) Maintenance LED WARNING UNINTENDED EQUIPMENT OPERATION You cannot check the maintenance LED from the front of the GP unit. • Design software by considering the possibility that touch operations may be performed while an error has occurred. •...
Page 12
Part Numbers and Functions (2) SD Card access LED Color Indicator Description Green The SD Card is inserted. (Active) The SD Card is not inserted or is not being accessed. (3) Ethernet LED Color Indicator Description Green Flashing Data transmission is occurring. (Active) Link No data transmission...
Interface Serial Interface Note: For information on how to connect controllers and other types of equipment, refer to the corresponding device driver manual of your screen editing software. DANGER ELECTRIC SHOCK The serial port is not isolated. The SG (signal ground) and the FG (frame ground) terminals are connected inside the unit.
Page 14
Interface 1. COM1 D-Sub 9 pin plug connector via an RS-232C cable. RS-232C Number Signal Name Direction Meaning Input Carrier Detect RD(RXD) Input Receive Data SD(TXD) Output Send Data ER(DTR) Output Data Terminal Ready – Signal Ground DR(DSR) Input Data Set Ready RS(RTS) Output Request to Send...
Page 15
Interface 2. COM2 D-Sub 9 pin plug connector via an RS-422/485 cable. RS-422/RS-485 Number Signal Name Direction Meaning Input Receive Data A (+) Input Receive Data B (–) Output Send Data A (+) Output Data Terminal Ready A (+) – Signal Ground Input Send Possible B (–)
Installation 1. Installation Method Panel type standard mount flat mount Resin boss type standard mount flat mount Panel type: Weld the stud bolts to the panel, and then tighten the nuts to fasten the GP unit to the panel. Resin boss type: Tighten the screws to attach the GP unit to the bosses of the resin boss-molded product.
Installation 2. Installation Requirements • Decide on the thickness of the enclosure wall, based on the level of strength required: For details, read chapter 3, "Panel Cut Dimensions" (see page 20). • Even if panel thickness is within recommended range for “Panel Cut Dimensions”, the panel could warp, depending on panel’s material, size, and installation location of GP unit or other devices.
Page 18
Installation • When installing the GP unit in a slanted position, the GP unit face should not incline more than 30 °. or less • When installing the GP unit in a slanted position with an incline more than 30 °, the ambient temperature must not exceed 40 °C (104 °F). You may need to use forced air cooling (fan, A/C) to ensure the ambient operating temperature is 40 °C or less (104 °F or less).
(0.04 in) (4.68 in (3.54 in or more maximum [+0.02, -0 in]) [+0.02, -0 in]) 3.2 mm (0.13 in) PFXGP4401TADR 155.3 mm 117.4 mm SPCC (+0.5, -0 mm) (+0.5, -0 mm) (JIS G (6.11 in (4.62in 3141) or [+0.02, -0 in]) [+0.02, -0 in])
Page 21
Installation • Flat mount Rear panel (resin plate) surface Rear panel (resin plate) surface a) Installation positions of stud bolts or positions of boss molds when attaching installation brackets at the top and bottom surfaces of the GP unit b) Installation positions of stud bolts or positions of boss molds when attaching installation brackets on either side of the GP unit d) 4-M4 x 10L stud bolts (no foreign material present on the base due to sparking or similar phenomena) or boss molds...
Installation 4. Panel Type NOTICE PANEL UNSTEADY WHEN UNSECURED Keep GP unit stabilized in the panel-cut while you are installing or removing the screw fasteners. Failure to follow the instruction can result in equipment damage.
Page 24
Installation Installation procedure Step Procedure Details Cut an opening in the panel to match the standard mount or flat mount panel cut dimensions, and then weld four M4 x 10L stud bolts perpendicular to the rear surface of the panel in order to fix the GP unit in place.
Page 25
Installation Attach the installation gaskets to the panel. Installation gaskets are included for the standard mount orientation and for the flat mount orientation. 1) The installation gakets for Flat mount 2) The installation gakets for Standard mount Peel off the removable paper layer, and then attach the adhesive surface to the rear surface of the panel as shown in the figure.
Page 26
Installation When the GP unit is shipped from the factory, installation brackets are fixed to its top surface and bottom surface. This corresponds to the standard mount orientation. If you are installing the GP unit in a panel with the GP unit in the same state as when it was shipped from the factory, read step 8.
Page 27
Installation Attach the installation brackets to the top and bottom surfaces of the GP unit or to the sides of the GP unit. In each case, attach the surface of the installation bracket that has six open holes to the GP unit.
Page 28
Installation When you are installing the GP unit horizontally, hold the GP unit so that the arrow pointing in the horizontal direction on the rear surface of the GP unit points up as shown in the figure. 1) Figure of the GP unit's rear surface when attaching installation brackets at the top and bottom surfaces of the GP unit 2) Figure of the GP unit's rear surface when attaching installation brackets on either side of the GP unit...
Page 29
133.3 (5.25) 105.5 (4.15) PFXGP4601TADR 158.5 (6.24) 118.7 (4.67) Note : Use the Overlay manufactured by Pro-face. Use one of the following models. • PFXZGPFSR6W1 (for the PFXGP4301TADR) • PFXZGPFSR7W1 (for the PFXGP4401TADR) • PFXZGPFSR10W1 (for the PFXGP4501TADR) • PFXZGPFSR12W1 (for the PFXGP4601TADR)
Page 30
Installation NOTICE BROKEN ENCLOSURE • Attach correctly without a crevice between gaskets and between gasket and the panel. • Do not attach installation fastener in a different position from mounting instruction. • Do not exert more than 0.8 N•m (7.1 lb-in) of torque when tightening the installation screws.
Page 31
Installation CAUTION RISK OF INJURY Be careful of the glass of the front of the GP unit. • Wear gloves when you are installing the GP unit. • Do not push the LCD panel strongly. • When installing the GP unit with the flat mount orientation, affix the Overlay to the front of the GP unit.
Installation 5. Resin Boss Type NOTICE PANEL UNSTEADY WHEN UNSECURED Keep GP unit stabilized in the panel-cut while you are installing or removing the screw fasteners. Failure to follow the instruction can result in equipment damage. Installation procedure Step Procedure Details Follow the standard mount or flat mount panel cut dimensions to perform sufficient tests in advance with designs that meet the following conditions, confirm the safety of the system, and then...
Page 33
Installation A) Resin plate B) Boss diameter: ø10.5 mm ± 0.5 mm (ø 0.41 in ± 0.02 in) C) Lower hole depth: 6 mm (0.24 in) or more D) Boss height: 20 mm (0.79 in) ± 0.1 mm (± 0 in) for the standard mount orientation E) Boss height and resin plate thickness* 19.5 mm (0.77 in) ±...
Page 34
Installation Attach the installation gaskets to the panel. Installation gaskets are included for the standard mount orientation and for the flat mount orientation. 1) The installation gakets for Flat mount 2) The installation gakets for Standard mount Peel off the removable paper layer, and then attach the adhesive surface to the rear surface of the resin plate as shown in the figure.
Page 35
Installation Slowly peel the protective sheet off of the GP unit's screen. Note : Peeling off the protective sheet with excessive force may peel off the film of the touch panel. When the GP unit is shipped from the factory, installation brackets are fixed to its top surface and bottom surface.
Page 36
Installation When you are installing the GP unit horizontally, hold the GP unit so that the arrow pointing in the horizontal direction on the rear surface of the GP unit points up as shown in the figure. 1) Figure of the GP unit's rear surface when attaching installation brackets at the top and bottom surfaces of the GP unit 2) Figure of the GP unit's rear surface when attaching installation brackets on either side of the GP unit...
Page 37
133.3 (5.25) 105.5 (4.15) PFXGP4601TADR 158.5 (6.24) 118.7 (4.67) Note : Use the Overlay manufactured by Pro-face. Use one of the following models. • PFXZGPFSR6W1 (for the PFXGP4301TADR) • PFXZGPFSR7W1 (for the PFXGP4401TADR) • PFXZGPFSR10W1 (for the PFXGP4501TADR) • PFXZGPFSR12W1 (for the PFXGP4601TADR)
Page 38
Installation NOTICE BROKEN ENCLOSURE • Attach the Overlay correctly with the installation. • Do not reuse the Overlay removed once. • Do not exert more than 0.8 N•m (7.1 lb-in) of torque when tightening the installation screws. • For use on a flat surface of a Type 1 Enclosure •...
Page 39
Installation Removal procedure Step Procedure Details Remove the screws from the four bosses fixed in place on the rear surface of the resin plate, and then slowly remove the GP unit from the resin plate. Removal diagram (profile) CAUTION RISK OF INJURY Be careful of the glass of the front of the GP unit.
Wiring Wiring WARNING HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • Remove all power from the device before removing any elements of the system, and prior to installing or removing any accessories, hardware, or cables. • Remove power before wiring the GP unit’s power terminals. •...
Wiring 1. Connecting the DC Power Cord Field wiring terminal marking for wire type (75 C (167 F) Copper conductors only) Power Cord Diameter 0.75 to 2.5 mm (18-13 AWG) Conductor type Simple or Stranded Wire Conductor length 0.39 *1 If the conductor’s end (individual) wires are not twisted correctly, the end wires may either short against each other or against an electrode.
Page 42
24 Vdc – 0 Vdc Grounded terminal connected to the panel chassis. Note: The DC power supply connector (plug) for PFXGP4301TADR/PFXGP4401TADR is PFXZCBCNDC1 (manufactured by Pro-face). The DC power supply connector (plug) for PFXGP4501TADR/PFXGP4601TADR is PFXZCBCNDC2 (manufactured by Pro-face). Recommended Driver SZS 0.6x3.5 (1205053)
Page 43
• To prevent the possibility of a terminal short, use a pin terminal that has an insulating sleeve. • The DC power supply connector for PFXGP4301TADR/PFXGP4401TADR can be connected to PFXGP4501TADR/PFXGP4601TADR. However, the DC power supply connector for PFXGP4501TADR/PFXGP4601TADR is unable to connect to...
Page 44
Wiring 2. Wiring Cautions Improving Noise/Surge Resistance • The GP unit’s power supply cord should not be bundled with or kept close to main circuit lines (high voltage, high current), power lines, or input/ output lines, and their various systems should be kept separate. When power lines cannot be wired via a separate system, use shielded cables for input/output lines.
USB Cable Clamp USB Cable Clamp When using a USB device, attach a USB cable clamp to the USB interface to prevent the USB cable from being disconnected. WARNING RECOMMENDATION FOR RESTRICTED AREAS • Verify the power, input, and output (I/O) wiring are in accordance with Class I, Division 2 wiring methods.
Page 46
• You can substitute the tie provided with PFXZCBCLUSA1 (manufactured by Pro-face) or other commercially available ties with a width of 4.8 mm [0.19 in] and thickness of 1.3 mm [0.05 in].
URL: http://www.pro-face.com/trans/en/manual/1002.html Names Registration Model No. GP-4300 Series GP-4301T PFXGP4301TADR GP-4400 Series GP-4401T PFXGP4401TADR GP-4500 Series GP-4501T (Analog Touch PFXGP4501TADR Panel) GP-4600 Series GP-4601T (Analog Touch PFXGP4601TADR Panel) The GP unit is manufactured in accordance with: •...
Page 48
Inquiry Do you have any questions about difficulties with your GP? Please access our site anytime that you need help with a solution. http://www.pro-face.com/trans/en/manual/1001.html Notes Please be aware that Digital Electronics Corporation shall not be held liable by the user for any damages, losses, or third party claims arising from the...
Need help?
Do you have a question about the PFXGP4401TADR and is the answer not in the manual?
Questions and answers