CONTROL BOARD FOR 230V HINGED GATES PLATINE ELECTRONIQUE POUR PORTAILS BATTANTS 230V EQUIPO ELECTRÓNICO PARA PORTONES DE TIPO BATIENTE 230V ELEKTRONISCHES GERÄT FÜR FLÜGELTORE 230V JA592 ISTRUZIONI PER L’USO – NORME DI INSTALLAZIONE USE AND INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L’EMPLOI – NORMES D’INSTALLATION INSTRUCCIONES PARA EL USO –...
Page 2
Normes indiquées au point 10. 6) GENIUS declines all liability caused by improper use or use other than that for 16) Les dispositifs de sécurité (norme EN 12978) permettent de protéger des which the automated system was intended.
ENGLISH CONTROL BOARD JA592 WARNINGS LAYOUT AND COMPONENTS Important: Before attempting any work on the control board (connections, maintenance), always turn off power. - Install, upstream of the system, a differential thermal breaker 6 7 8 9 10 11 12 1 2 3 4 (Residual Current Device) with adequate tripping threshold.
Page 4
ENGLISH Opening/closing safety devices: they operate during the gate 4.1. Connection of photocells and safety devices opening and closing movements and, therefore, they Before connecting the photocells (or other devices) we advise are suitable for the opening and closing areas against you to select the type of operation according to the movement the risk of impact.
Page 5
ENGLISH Connection of 1 pair of closing photocells Connection of 2 N.C. contacts in series (e.g. Photocells, Stop) 9 10 11 12 13 14 15 16 17 18 19 20 21 CL OP LOCK +24V W.L. OPEN Fig. 12 Connection of 2 N.O. contacts in parallel (e.g.
Page 6
WHITE Encoder 1 BLACK WHITE Encoder 2 BLACK N.B.: Maximum configurations are shown on the drawings. All JA592 intermediate configurations are allowed, using only some elements (only 1 encoder, only 1 limit-switch, 2 encoders Fig. 16 and 2 limit-switches etc.).
Page 7
ENGLISH 5. MICROSWITCH PROGRAMMING LEAF 1 FORCE LEAF 2 FORCE OPENING LEAF DELAY (s) 1 (MIN) 1 (MIN) CLOSING PHOTOCELL LOGIC 8 (MAX) 8 (MAX) REVERSES ON RELEASE REVERSES IMMEDIATELY 10 11 12 LOGIC PAUSE (s) SW10 FAIL SAFE CLOSING LEAF SW11 SW12 DELAY (s)
Page 8
ENGLISH •Limit switches or encoder must be used in condominium 6.2. ROTATION DIRECTION AND FORCE CHECK applications in order to guarantee the repeatability of Program the functions of the control board according to the slow-down. Otherwise the leaf could not reach the need, as shown in Chapter 5.