Service Codes - Zodiac Pool Systems Nature2 Fusion soft Installation And Operation Manual

Hide thumbs Also See for Nature2 Fusion soft:
Table of Contents

Advertisement

7.2

Service Codes

Code Number
120
121
123
124
125
126
127
144
145
170
171
172
173
174
175
Nature
Fusion Soft Installation and Operation Manual
Possible Cause
Low current in forward direction to cell.
Low current in reverse direction to cell.
Extremely low current to cell.
Higher than normal current to cell.
Cell needs to be cleaned.
Low current in forward direction and VAC
input voltage below 100/200 VAC.
Low current in reverse direction and VAC
input voltage below 100/200 VAC.
Low salinity (below 2.0 gpl).
High salinity (above 4.0 gpl).
Possible front board service condition or unit
not correctly wired to 120 VAC.
Possible backboard service condition.
Flow sensor service condition or fl ow sensor
is unplugged.
Low VAC input voltage and on board power
supply is not regulated or unit not correctly
wired.
Pool temperature is too high for operation of
Nature
2
Fusion Soft.
Flow sensor air lock condition or very low
salinity.
Corrective Action
1. Clean cell if necessary (see Section 6.5).
2. Check DC Cord.
1. Clean cell if necessary (see Section 6.5).
2. Check DC Cord.
1. Clean or replace cell if necessary (see
Section 6.5).
2. Check DC Cord.
Contact a qualifi ed service representative.
Clean cell if necessary (see Section 6.5).
Contact a qualifi ed service representative.
Contact a qualifi ed service representative.
Add salt to pool to achieve 3.0 gpl (see Section
4.6).
Backwash fi lter if a DE fi lter is installed.
Partially drain pool and dilute with fresh water
until salinity returns to 3.0 to 3.5 gpl.
Contact a qualifi ed service representative.
Contact a qualifi ed service representative.
Contact a qualifi ed service representative.
Unit wired to improper AC voltage. Contact a
qualifi ed service representative.
Flow/Salinity Sensor indicates water
temperature at sensor above 108ºF (42°C).
Reduce water temperature.
Verify proper fl ow/temp/salinity sensor
installation (see Section 3, Figure 10). Check
salinity with Myron "L" meter calibrated for
NaCl or test strips. Add salt as necessary (see
Section 4.6).
Page 45