Removal Of Fan Motor / Fan Rotor - Daikin FTXS30LVJU Service Manual

Inverter pair ftxs-l series fdxs-l series
Hide thumbs Also See for FTXS30LVJU:
Table of Contents

Advertisement

Indoor Unit: FTXS15/18/24LVJU
2.7

Removal of Fan Motor / Fan Rotor

Procedure
Step
1. Remove the right side
plate.
1
Remove the 2 screws.
2
Lift the right side plate
and remove it.
2. Remove the fan rotor.
1
Remove the screw of
the fan motor fixing
plate.
217
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Right side plate
(R16306)
(R16307)
Fan motor
fixing plate
(R16972)
SiUS091133
Points
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTXS30LVJU and is the answer not in the manual?

Questions and answers

Randy L. Niesen
February 7, 2025

My Daikin RXS24LVJU unit has quit working. It is still under warrantee. How do we get it to work again. I bought it through Cygnatr're Heating & Air Inc. in Redmond Oregon, but it seems as though none of his phone numbers are working now.

1 comments:
Mr. Anderson
February 10, 2025

Contact your dealer or a professional technician authorized by Daikin for troubleshooting and repairs. Do not attempt to disassemble or repair the unit yourself, as this may void the warranty. Ensure you have the warranty details and proof of purchase when requesting service.