The A/D calibration data is corrupt. When the information modes are accessed (P61100)
this message will be displayed for 1 second and P61113 – P61116 are defaulted to a
factor of 1. This will also happen on power-up if the check-sum for the A/D data are
corrupted.
Error reading data from the EEPROM. Possible U27 or U28 problem.
Error writing data to the EEPROM. Possible U27 or U28 problem.
Supplementary error message for above errors.
The setup being attempted requires more EEPROM than is currently installed.
Upon power-up the indicator has not found the proper codes. Therefore, all parameters
have been reset to factory default values.
The stored data has a checksum error. Check all parameters or re-load setup.
The indicator cannot use the EEPROM for data storage and is attempting to power-up
again to cure the problem.
2
The E
is corrupted in the PIN section. Check E
defaulted to the manufacturer (GSE) access code. Also refer to Error 11.
C
ALIBRATION
The entered calibration weight, together with the currently applied signal, indicates
that the full scale signal will be greater than the allowed maximum of the controller.
Verify that correct entries have been made for the capacity, P110, and for the
calibration weight. If all appears correct, refer to the use of the information parameter
P61100, and determine the output (in mV / volt) of the connected load cell.
The entered calibration weight, together with the currently applied signal, indicates
that the full scale signal will be less than the allowed minimum of the controller. Verify
the proper entries for the capacity, P110, and for the calibration weight. If all appears
correct, refer to the use of the information parameters, P61100, and determine the
output (in mV / volt) of the connected load cell.
The applied weight during calibration was less than 0.1% of capacity. More weight
than this is required. Refer to P61100 if this is incorrect.
The just completed calibration is insufficient to guarantee accurate results due to
either the cal weight being less than 5% of capacity or this was the first calibration of
this platform to this Indicator and, therefore, the coarse gain was adjusted by the
Indicator.
The current combination of capacity P110 and increment P111 result in a resolution
greater than 25,000 graduations. This is simply a warning in case this was not
intended.
The current combination of capacity P110 and increment P111 result in a resolution
greater than 100,000 graduations. This is not allowed and as soon as any key is
pressed the controller will jump back into the setup mode to parameter P110 to verify
the settings.