Do you have a question about the Inverter+ WAS Series and is the answer not in the manual?
Questions and answers
David C Bussard
January 26, 2025
uNIT wont heat
1 comments:
Mr. Anderson
February 10, 2025
The Pioneer Inverter+ WAS Series unit may not be heating due to the following reasons:
1. Temperature Setting: The set temperature may be higher than the ambient room temperature. Lower the temperature setting. 2. Dirty Heat Exchanger: The heat exchanger on the indoor or outdoor unit may be dirty. Clean the affected heat exchanger. 3. Dirty Air Filter: The air filter may be dirty, restricting airflow. Remove and clean the filter according to the instructions. 4. Blocked Air Inlet or Outlet: The air inlet or outlet may be obstructed. Ensure there are no blockages. 5. Defrost Mode: During defrost mode, the outdoor fan stops, temporarily preventing heating. Wait for the cycle to complete. 6. Low Ambient Protection: If the outdoor temperature is lower than -13°F (-25°C), the unit may stop heating. It will restart when conditions improve. 7. System Malfunction: If operation is erratic or unresponsive, reset the power by disconnecting and reconnecting it. If the issue persists, contact customer service with details of the malfunction and model number.
This answer is automatically generated
Eric G A Gee
April 25, 2025
where is the SWING/DIRECT button? on the WAS/WYS Series
Ductless mini split system air conditioner / heat pump, uab: cooling only version / uyb: cooling and heating version series flex mount, inverter plus and inverter plus plus models, 18,000-48,000 btu/hr (18 pages)
Need help?
Do you have a question about the Inverter+ WAS Series and is the answer not in the manual?
Questions and answers
uNIT wont heat
The Pioneer Inverter+ WAS Series unit may not be heating due to the following reasons:
1. Temperature Setting: The set temperature may be higher than the ambient room temperature. Lower the temperature setting.
2. Dirty Heat Exchanger: The heat exchanger on the indoor or outdoor unit may be dirty. Clean the affected heat exchanger.
3. Dirty Air Filter: The air filter may be dirty, restricting airflow. Remove and clean the filter according to the instructions.
4. Blocked Air Inlet or Outlet: The air inlet or outlet may be obstructed. Ensure there are no blockages.
5. Defrost Mode: During defrost mode, the outdoor fan stops, temporarily preventing heating. Wait for the cycle to complete.
6. Low Ambient Protection: If the outdoor temperature is lower than -13°F (-25°C), the unit may stop heating. It will restart when conditions improve.
7. System Malfunction: If operation is erratic or unresponsive, reset the power by disconnecting and reconnecting it. If the issue persists, contact customer service with details of the malfunction and model number.
This answer is automatically generated
where is the SWING/DIRECT button? on the WAS/WYS Series