GPRS/3G Gate Opener
Remote Access Control
GSM Gate, Barrier, Shutter, Garage
Door and Door opener
Open gate or garage door with a
FREE call from your mobile phone!
Remote switching machines with a
FREE call from your mobile phone!
User Manual
Ver. 1.7
RTU5025 Series
Date Issued: 2016-03-25
All rights reserved
www.GSM-Gate-Opener.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTU5025 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for King Pigeon RTU5025 Series

  • Page 1 Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GPRS/3G Gate Opener Remote Access Control User Manual Ver. 1.7 RTU5025 Series Date Issued: 2016-03-25 All rights reserved www.GSM-Gate-Opener.com...
  • Page 2: Table Of Contents

    King Pigeon its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook. King Pigeon its employees and distributors, accept no liability for GSM Network upgrading or SIM Card upgrading due to the technology specifications contained in this handbook.
  • Page 3: Product Details

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 1. Product details The RTU5025 is an upgraded version of famous RTU5015 gate opener, a very simple device which can be used for remote control swing or sliding gates and doors or switching devices with authorized access management(Caller-ID),well used on door access, gate control, remote switching, or car parking systems.
  • Page 4: Standard Packing List And Model Tabel

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005.  Gate Opener * 1  Antenna * 1 Order Table:  AC/DC Power adaptor *1, RTU5025: GSM 850/900/1800/1900MHz  User Manual & PC Software CD x1 RTU5025W: 2G: GSM900/1800MHz, ...
  • Page 5: Typical Wiring Connection

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. INDICATORS Power ON: AC/DC power supply is ON. Alarm Flash quickly: Alarm occurrence. Relay ON: Relay closed(ON). Flash per 1 second(quickly): registering to cellular network. Flash per 2 seconds: Normal status. OFF: can’t connect to SIM card or unregistered to the cellular network Connection Terminals Power supply input, Positive wire(Red).
  • Page 6 A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. RTU5025 for Gate opener: Connect the door sensor to DIN1 for door status detection, and siren for alarm sound, the lock switched ON/OFF by phone call, power gain from the same AC/DC adaptor. RTU5025 for remote switching pump: Connect the water level sensor to DIN2 for level detection, and siren for alarm sound, the pump switched ON/OFF by phone...
  • Page 7: Setting By Pc Software

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. Open the unit's back cover and insert the SIM card. Connect the unit's power supply. pwdTEL phone number of the RTU5025 Send SMS command to set the time. Do not include the "", example:1234TEL001911# , this step is MUST.
  • Page 8: Authorized Number List Managerment

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 2) Edit Authorized Number List  If the software shows “ERROR” message when you setting the date & time for the users, please try to change your computer’s data &...
  • Page 9: Setting/Operating By Sms Commands

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 6. Setting by SMS commands( not recommend, for remote setting only Notice: 1. The default Password is 1234. 2. You can program the RTU5025 by APP or SMS commands using your phone. It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it, we also use a Password that makes it impossible for others who doesn't know it, to access the system by chance, and all the action will be recorded.
  • Page 10: Change Password

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 6.0 Start ( this step is MUST): Send pwdTELphone number of the RTU5025# to the RTU5025 for adjust the time. “00861351015” is the SIM card number which inside of the RTU5025. E.g.: 1234TEL00861351015# Return: Set Success!
  • Page 11: Relay Control Parameters

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 6.2.2 Inquiry batch users number pwd AL serial number start # serial number end # E.g.: 1234AL002#050# to inquiry the 2 to the 50 users,RTU5025 return several SMS with the numbers list(10 numbers on each SMS).
  • Page 12: Digital Input Parameters

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 6.3.6 Control the relay ON/OFF by SMS command pwdCC Return SMS: Relay ON (or the SMS confirmation content which you modified before) pwdDD Return SMS: Relay OFF(or the SMS confirmation content which you modified before) pwdGOT close time # The relay close timer according to the before setting 6.3.3: 6.4 Digital Input.
  • Page 13: Self-Check Auto Report/Inquiry Status/Imei Code And Firmware Version

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. The DIN1/DIN2 will trigger an alarm only under the below two conditions  RTU5025 under the Armed Mode  10mins after the last call in from the authorized numbers. (10mins default, users can modify the time period by SMS command: pwdDxxx# xxx=000~999, unit: minute...
  • Page 14: Data Function

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. pwdIMEI# 6.5.5 RESET the password Press and hold the RESET button(closed to the SIM card holder), then power ON, after 6 seconds later, the RTU5025 will restart, then release the RESET button. This operation will reset the password to default 1234 only, other parameters reset must be reset by PC software.
  • Page 15: Important Information

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. xxxx=0000~9999, (unit: minute) xxxx=0000, data function always on,RTU5025 can receive and send data over GRPS/UMTS/HSDPA. xxxx=9999, disable data upload function, default. 7. Important information 1) Please read the User Manual carefully before you install and control the RTU5025. 2) Install the RTU5025 in a hidden place.
  • Page 16: Authorized Users List Paper

    A Professional GSM 3G M2M products manufacturer and automation solution provider, since 2005. 10. Authorized users list (print this page and fill in for record) Position User Phone number User Name Always Specific time access … _________________________________________________________________________________________ Page 16 of 17 Ver.