TABLE OF CONTENTS - PRELIMINARY ADVICE..................... PAGE USER MANUAL - OPERATION....................... PAGE 2.1 - Complete system arming..................PAGE 2.2 - System arming with sensor and comfort control exclusion........PAGE 2.3 - Passive arming......................PAGE 2.4 - Arming inhibit time....................PAGE 2.5 - System armed......................
Before installing, identify your alarm model and refer to it for the correct instructions GEMINI 822: same as 823 without self-powered battery. The following signs, intended for the installer or the user, indicate particular functions or connections as follows: For the user.
2.4 - ARMING INHIBIT TIME The inhibit arming time lasts approximately 30” and is indicated by the LED turned ON; it is possible to exit the vehicle without triggering any alarm 2.5 - SYSTEM ARMED After the inhibit time the system is “armed” and ready to detect any theft attempt. When the system is fully armed, the LED flashes.
The warranty will become void if labels are missing or torn, if the installation certificate is not fully compiled or if the enclosed sale document is missing. The guarantee is valid exclusively at authorized Gemini Technologies S.p.A. Service Centers. The manufacturer declines any responsibility for eventual malfunctions of the device or any damage to the vehicle electrical system due to improper installation, use or tampering.
6.0 - COMPLETE ELECTRIC DIAGRAM Disconnect the negative battery terminal before carrying out electrical connections. Connection Reconnect ONLY after you of unit 823 are done. (with siren) ELECTRONIC KEY Green Brown Black BLACK marked “R” BLACK Antenna, do not tamper POSITIVE Battery GREEN-BLACK...
CONNECTIONS FOR ARMING VIA TURN INDICATORS 7.1 - STANDARD CONNECTION LEFT TURN RIGHT TURN INDICATORS INDICATORS ORANGE GEMINI 823 ORANGE SYSTEM WHITE-ORANGE WHITE-ORANGE wire must ONLY be connected if the system is to be armed/disarmed via the turn indicators. 7.2 - CONNECTIONS FOR VEHICLES WITH SEPARATE LINES...
Arming via the turn indicators flashes, the actuators and the lock/unlock switches 8.1 - CONNECTIONS TO ACTUATORS WITH A SEPARATE RADIO RECEIVER Arm/disarm connections for vehicles with a radio receiver that is separate from CDL (see www.gemini- alarm.com for diagram “A” connection). Set dip-switch nr. 4 “ON”.
10.0 - SYSTEM PROGRAMMING The t able below applies to the system programmed in “standard configuration”. very time you enter the programming procedure, the alarm resets to the default settings FUNCTION STATUS LED FLASHES Exclusion of arm/disarm optic signals Disabled Exclusion of arm/disarm acoustic signals Enabled System passive arming...
10.7 - NEGATIVE OUTPUT SELECTION (DURING ALARM) FOR HORNS OR ADDITIONAL SIREN Depending on the connection made, this function can activate the output for the siren (continuous tone) or for the horn (intermittent tone 11.0 - SYSTEM PROGRAMMING EXAMPLE The following example illustrates the steps to follow to modify the programmable functions. As mentioned before, turning the key OFF/ON disables the function, while using the electronic key enables it.
12.0 - DIP-SWITCHES PROGRAMMING TABLE Set dip-switches BEFORE connecting the alarm system. If settings must be modified after installation, FIRST disconnect the alarm and then reset the dip-switches. POSITION FUNCTION POSITIVE polarity for control on WHITE/LIGHT BLUE wire NEGATIVE polarity for control on WHITE/LIGHT BLUE wire Positive signal (+A) on BROWN/RED with alarm ON Standard operation Negative output to arm/disarm the system...
14.0 - ADDING NEW DEVICES To carry out the operation successfully, make sure the required electrical connections (door/bonnet switches and ignition) are complete. Storing memory is for 55 devices If an extra device is added, it will automatically delete the first device programmed in the system memory To activate the procedure proceed as follows: With the system disarmed, open the driver door and the bonnet and leave them open...
15.0 - DELETING PROGRAMMED DEVICES To carry out the operation successfully, make sure the required electrical connections (door/bonnet switches and ignition) are complete. Any previously programmed device can be erased as follows With the system disarmed, open the driver door and the bonnet and leave them open The following operations must be carried out within 4 seconds otherwise the procedure is invalidated.
16.0 - SYSTEM RESET By activating the following procedure, the system returns to the factory default settings. This procedure must therefore only be used in case of need, before programming the system or auto-learning the turn indicator flashes. To reset the system proceed as follows: Switch-off the system power supply...
Page 16
7 Dudley Court , Jessop Close, Clacton-on-Sea, Essex, CO15 4LY TEL: +44 (0) 1255 434353 Email: sales@avsgemini.com | Web: www.avsgemini.com UK Distributors of the Gemini Alarm Systems...
Need help?
Do you have a question about the 823 Series and is the answer not in the manual?
Questions and answers