Toshiba e-STUDIO163 Service Manual page 182

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:
Table of Contents

Advertisement

(4)
Remove 2 plate springs fixing the doctor
sleeve on its both ends.
(5)
Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Note:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(Refer to Service Handbook Chap.3.8)
(6)
Remove 1 screw and take off the polarity
adjustment lever.
Note:
Make a note of the position where the polar-
ity adjustment lever is pointing. (Mark the
position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
e-STUDIO163/203 DEVELOPMENT SYSTEM
Plate spring
Coil spring
Screw
12 - 14
Plate spring
Fig. 12-16
Coil spring
Screw
Fig. 12-17
Polarity adjustment lever
Fig. 12-18
December 2005 © TOSHIBA TEC