9.1 Indoor Unit Error Display

Operation
Timer lamp
lamp
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 5 times
Display
LED STATUS
X
E0
Indoor unit EEPROM parameter error
X
E1
Indoor / outdoor units communication error
X
E3
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short
X
E4
circuit
Evaporator coil temperature sensor T2 open circuit or
X
E5
short circuit
X
EC
Refrigerant leakage detection
O
F0
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or
O
F1
short circuit
Condenser coil temperature sensor T3 open circuit or
O
F2
short circuit
Compressor discharge temperature sensor T5 open
O
F3
circuit or short circuit
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed has been out of control
P0
IPM malfunction or IGBT over-strong current protection
P1
Over voltage or over low voltage protection
High temperature protection of compressor top
P2
diagnosis and solution
P4
Inverter compressor drive error
O(light)
X(off)
PRODIGY Technical Manual