Output Terminal Selections For Am, Fm, Fp, And Analog 1&2 Terminals - Toshiba Q7 Installation And Operation Manual

Table of Contents

Advertisement

The magnitude of the AM/FM output signal at full-scale is selection-specific and may be
adjusted to fit application-specific requirements (see the
Terminal Adjustment
shows the default full-scale output setting of the AM/FM terminal for each selection.
Table 6
The column on the right side of
of 100% (default setting).
Table 6. Output terminal selections for the AM, FM, FP, and Analog 1&2 terminals.
Function
Output Frequency
Frequency Reference
Output Current
DC Bus Voltage
Output Voltage
Post-compensation Frequency
Speed Feedback (realtime)
Speed Feedback (1 sec filter)
Torque
Torque Command
Internal Torque Base
Torque Current
Excitation Current
PID Feedback Value
Motor Overload Ratio
ASD Overload Ratio
DBR Overload Ratio
DBR Load Ratio
Input Power
Output Power
Peak Output Current
Peak DC Bus Voltage
PG Counter
Position Pulse
RR Input
VI/II Input
RX Input
RX2 Input
FM Output (used for factory testing only)
AM Output (used for factory testing only)
Meter Adjust Value
Analog Output
Load Torque
48
).
parameters
shows the actual AM/FM output for a keypad display
Table 6
AM Terminal Adjustment
AM/FM Output Value at
100% Displayed Output at
the Keypad
Maximum Frequency
150%
Maximum Frequency
150%
Maximum Frequency
Motor Overload Trip Point Setting
ASD Overload Trip Point Setting
DBR Overload Trip Point Setting
Maximum DBR Duty Cycle
1.73 * input voltage * ASD rated current
150%
32767 Encoder Pulses
100%
150%
Q7 ASD Installation and Operation Manual
and the
FM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents