Yamaha CDX-E400 Service Manual
Hide thumbs Also See for CDX-E400:

Advertisement

MINI COMPONENT SYSTEM
CDX-E400
The CRX-E400 is composed of the
RX-E400 and the CDX-E400. This
service manual is for the CDX-E400.
For the RX-E400 service manual,
please refer to the following publication
number :
RX-E400
100809
For the system operation, please refer
to the service manual for the RX-E400.
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherant to the industry, and more specifically YAMAHA Products, are already
known and understood by the users, and have therefore not been restated.
WARNING:
IMPORTANT:
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and
service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable
and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact
the distributor's Service Division.
WARNING:
IMPORTANT:
I
CONTENTS
TO SERVICE PERSONNEL ..................................... 2-3
REAR PANELS ............................................................. 4
SPECIFICATIONS ......................................................... 5
INTERNAL VIEW .......................................................... 5
DISASSEMBLY PROCEDURES .............................. 6-8
STANDARD OPERATION CHART ........................ 9-10
TEST MODE .......................................................... 11-12
ERROR MESSAGE ............................................... 13-14
1 0 0 8 0 8
SERVICE MANUAL

IMPORTANT NOTICE

Failure to follow appropriate service and safety procedures when servicing this product may result in personal
injury, destruction of expensive components and failure of the product to perform as specified. For these reasons,
we advise all YAMAHA product owners that all service required should be performed by an authorized
YAMAHA Retailer or the appointed service representative.
The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or
recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form.
Static discharges can destroy expensive components. Discharge any static electricity your body may have accumu-
lated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss).
Turn the unit OFF during disassembly and parts replacement. Recheck all work before you apply power to the unit.
IC DATA ................................................................ 15-19
DISPLAY DATA .......................................................... 20
BLOCK DIAGRAM ...................................................... 21
PRINTED CIRCUIT BOARD ................................ 22-23
IC BLOCK ................................................................... 24
PIN CONNECTION DIAGRAM ................................... 24
SCHEMATIC DIAGRAM ............................................. 25
PARTS LIST .......................................................... 27-34
CRX-E400

Advertisement

Table of Contents
loading

Summary of Contents for Yamaha CDX-E400

  • Page 1: Table Of Contents

    This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherant to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and have therefore not been restated.
  • Page 2: To Service Personnel

    CDX-E400 TO SERVICE PERSONNEL 1. Critical Components Information AC LEAKAGE Components having special characteristics are marked Z EQUIPMENT WALL TESTER OR OUTLET UNDER TEST EQUIVALENT and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Models Only)
  • Page 3 CDX-E400 Laser Diode Properties Material : GaAlAs Optical Pick-up Wavelength : 780 nm Emission Duration : Continuous : max. 44.6 µW* Laser Output * This output is the value measured at a distance of about 200 mm from the objective lens surface on the Optical Pick-up Block.
  • Page 4: Prevention Of Electro Static Discharge

    CDX-E400 I PREVENTION OF ELECTRO STATIC DISCHARGE The laser diode in the CD mechanism unit (optical pickup) may be damaged due to static electricity from clothes or the human body. Use caution to prevent electrostatic damage when servicing or handling the laser diode.
  • Page 5: Specifications

    CDX-E400 SPECIFICATIONS DIMENSIONS Output Level 2.0 ± 0.5Vrms 1kHz, 0dB Signal to Nosie Ratio (EIAJ) 102dB Dynamic Range 95dB Harmonic Distortion+Noise (1kHz) 0.004% Frequency Response ±0.5dB 2Hz — 20kHz Power Requirements B, G models 230V AC 50Hz R model 110/120/220/240V AC 50/60Hz...
  • Page 6: Disassembly Procedures

    CDX-E400 DISASSEMBLY PROCEDURES (Remove parts in disassembly order as numbered.) 1. Removal of Top Cover a. Remove 4 screws ( q ) and 4 screws ( w ) in Fig. 1. b. Lift the Top Cover at the rear and move it rear-ward slantingly.
  • Page 7 CDX-E400 Servicing Position a. Remove the Top Cover, Front Panel and CD Mechanism Unit. b. Remove 3 screws (y) and 2 screws (u) in Fig. 3. c. Loosen the style pin (PN1) to set W401 free in Fig. 3. d. With the rear panel attached, remove the Main P.C.B.
  • Page 8 CDX-E400 4. Removal of Tray Unit Stopper Pin Chucking Unit a. Remove 2 screws ( i ) and then remove the Chuck- ing Unit in Fig. 7. b. Remove 1 hook and then remove the Stopper Pin in Stopper Fig. 7.
  • Page 9: Standard Operation Chart

    CDX-E400 STANDARD OPERATION CHART POWER ON If a disc is not loaded, “– –:– –” appears in the time indicator. Press OPEN/CLOSE key. “ OPEN ” appears in the indicator. “TRV” signal is output until detection of LIMIT switch. Forced feed return operation...
  • Page 10 CDX-E400 Tracking gain rough ADJ Tracking balance ADJ (only tray OPEN/CLOSE) Focus balance ADJ Focus gain ADJ Tracking gain ADJ * TOC READ ~ * Data fetch cycle ~ TRACK NO. “1” is searched. : MUTE OFF = “H” → “L” (Q7 Collector) After searching the beginning, MUTE is cancelled.
  • Page 11: Test Mode

    CDX-E400 TEST MODE When the power off, press the “STANDBY/ON” key while pressing the “ ” key and the “ ” key and then release your fingers from those keys. Note: At this time, “ ” key must be pressed before “...
  • Page 12: Test Mode

    CDX-E400 Command Command FUNCTION Name 150K. Rev Reverse 150 tracks kick continuously. 150K. Fwd Forward 150 tracks kick continuously. PrdctMode Returns to product mode. Error Msg Display the latest error message. (see page 13) Test Eep Check EEPROM. (Mute on if test OK. Mute off if test NG) Check FL Check FL display.
  • Page 13: Error Message

    CDX-E400 ERROR MESSAGE (1) If stopped by any cause, error message can be displayed by pressing the remote STOP key while pressing and holding the panel STOP key, or by test mode command number 23. The player holds the latest error message in EEPROM. So even if stopped with no error, the latest error message can be displayed with same operation.
  • Page 14 CDX-E400 c) Operates as if no disc loaded. (although loaded) 2) Troubleshooting from System Malfunctions a) Tray fails to come out/go in. Does tray Poor tray loading load properly? Poor mechanism Tray starts to operation move but stops. Wire caught.
  • Page 15: Ic Data

    CDX-E400 IC DATA IC103 : µPD78076GF-108-3BA 8bit µ-COM Function Name Port OPSW Opened state of tray sensing switch input. Opened state at “L”. P120/RTP0 CLSW Closed state of tray sensing switch input. Closed state at “L”. P121/RTP1 N.C. P122/RTP2 MUTE Sound output at “H”...
  • Page 16 CDX-E400 IC103 : µPD78076GF-108-3BA 8bit µ-COM Port Name Function P13/ANI3 N.C. P14/ANI4 DATA port for EEPROM. P15/ANI5 DATA CLOCK for EEPROM. P16/ANI6 N.C. P17/ANI7 LDRCTL Laser ON control AVSS AVSS P130/ANO0 OP/CL N.C. P131/ANO1 GCTRL Gain and APC control AVREF1...
  • Page 17 CDX-E400 IC103 : µPD78076GF-108-3BA 8bit µ-COM Port Name Function P67/ASTB Pull down P100/TI5/TO5 P101/TI6/TO6 N.C. P102 P103 P30/TO0 close Tray open signal output P31/TO1 open Tray close signal output P32/TO2 P33/TI1 P34/TI2 N.C. P35/PCL P36/BUZ STAN M56748 standby control Pull down...
  • Page 18 CDX-E400 IC102 : MN35511AL Signal Processor & Controller Pin No. Name Function BCLK Bit clock output for SR DATA (NC) LRCK L/R identification signal output (NC) SRDATA Serial data output (NC) DVDD1 Power supply for digital circuit (+5) DVSS1 GND for digital circuit...
  • Page 19 CDX-E400 IC102 : MN35511AL Signal Processor & Controller Pin No. Name Function DSLF Loop filter terminal for DSL PLLF Loop filter terminal for PLL VCOF Loop filter terminal for VCO (+5) AVDD2 Power supply for analog circuit (for AD of DSL, PLL, DA output blocks)
  • Page 20: Display Data

    CDX-E400 DISPLAY DATA (V3618100) V301 : 14-BT-56GN &0 PATTERN AREA G PIN CONNECTION Pin No. Connection F1 NP 14G 13G 12G 11G 10G 9G 8G 7G 6G 5G 4G 3G 2G NX NX NX NX 1G IC P35 P34 P33 P32 P31 P30 P29 P28 Pin No.
  • Page 21: Block Diagram

    CDX-E400 BLOCK DIAGRAM CD MECHA. UNIT XL101 PICK UP OUT L HEAD IC101 CONTROL LINE OUT AN8399SA LD DRIVE IC102 IC105 IC105 MN35511AL VREF OUT R SPC+DAC MUTE IC303 KICK CONTROL M56789FP D1—5 DIGITAL OUT 6 TX TA— OPTICAL MDATA FA—...
  • Page 22: Printed Circuit Board

    CDX-E400 PRINTED CIRCUIT BOARD (Foil side) MAIN ( 1 ) P. C. B. Semiconductor Location Ref. No. Location FROM : CD MECHANISM UNIT FA– TA– D101 FROM : MAIN (3) D102 D103 VREF D104 D105 D106 Ref. No. Location IC101...
  • Page 23: Printed Circuit Board

    CDX-E400 PRINTED CIRCUIT BOARD (Foil side) Point e (Pin 58 of IC301) MAIN ( 2 ) P. C. B. V : 2V/div, H : 0.2µsec/div DC, 1 : 1 probe FROM : MAIN (1) STANDBY/ /BLK MAIN ( 3 ) P. C. B.
  • Page 24: Ic Block

    CDX-E400 IC BLOCK IC303 : M56789FP IC101 : AN8399SA IC301 : LC75710NE 4-Channel Actuator Driver CD Head Amp FL Driver – – VREFO VREF VCC2 SHIFT DC RAM 24 25 REGISTER AM32 SOUT1 AM31 SIN1– AM30 AM29 RF EQ OFTR...
  • Page 25: Schematic Diagram

    CDX-E400 SCHEMATIC DIAGRAM MUTING –5.0 –5.0 SPC & DAC –5.1 –5.0 LD DRIVE CD HEAD AMP MUTE CONTROL –10.2 –0.4 –0.5 10.2 EEPROM ACT. MOTOR DRIVER POWER SUPPLY SYSTEM CONTROL AC19.6 10.2 µPD78076GF-108-3BA AC3.7 10.2 –28.2 –32.1 –22.1 MOTOR DRIVER –12.6...
  • Page 26: Parts List

    CDX-E400 P ARTS LIST WARNING Components having special characteristics are marked and must be replaced with parts having specifications equal to those originally installed. ELECTRICAL PARTS Carbon resistors (1/6W or 1/4W) are not included in the ELECTRICAL PARTS List. For the part Nos. of the carbon resistors, refer to the last page.
  • Page 27 CDX-E400 % : Note on the Main PCB Of the main PCB part Nos., only the gold (GD) type part Nos. are included in the table. (G, B models) The only different part between the silver (SI) and gold (GD) type parts is the sheet/FL that is attached to the fluorescent character display tube.
  • Page 28 CDX-E400 Schm Schm Ref. PART NO. Description Market Ref. PART NO. Description Market C403 UR828100 C.EL 100uF ST501 V4040500 SCR.TERM * D1 V8911600 DIODE DIN60-4084 ST502 V4040500 SCR.TERM * D2 V8911600 DIODE DIN60-4084 SW301 VV020300 SW.TACT SKQNAA VD631600 DIODE 1SS133,176 SW302 VV020300 SW.TACT...
  • Page 29: Exploded View

    CDX-E400 EXPLODED VIEW R model 2 (4) 2 (3) 1-111 2 (2) 2 (1) 1-111 1-11 1-103 1-110 1-102 1-101 1-110 1-104 1-103...
  • Page 30 CDX-E400 MECHANICAL PARTS Ref. PART NO. Description Remarks Markets 1-11 MF114100 FLEXIBLE FLAT CABLE 14P 100mm * 1-101 V8782200 FRONT PANEL * 1-101 V8782300 FRONT PANEL * 1-102 V8782400 SUB PANEL-CDX * 1-102 V8782500 SUB PANEL-CDX * 1-103 V8785200 PANEL/SIDE...
  • Page 31 CDX-E400 EXPLODED VIEW (CD Mechanism Unit) Stopper * The stopper is not supplied with the tray as a spare part. When replacing the tray, keep the removed stopper and reuse it. Should it be lost and a new one be necessary, order service part Main Chassis (S) and remove the stopper only from it and use it as a spare part.
  • Page 32 CDX-E400 MECHANICAL PARTS (CD Mechanism Unit) Ref. PART NO. Description Remarks Markets VZ573200 CD MECHANISM UNIT KSL-2130CCM CX680620 TRAY (C) 2130 264629001 CX675250 GEAR COVER (S) 262554401 CX675210 TRAY GEAR (S) 262553501 AX619150 CHUCKING PLATE (S) 262554601 EX602890 BW HEAD P-TITE SCREW 2.6x7...
  • Page 33 CDX-E400 EXPLODED VIEW (Drive Unit) Note : The parts marked with an asterisk ( ) are not available separately. Cover Ref. PART NO. Description Remarks Markets NX635420 MOTOR CHASSIS ASS'Y (MB) X26258771 CX679710 MOTOR GEAR ASS'Y X26257691 AX623980 SLED SHAFT...
  • Page 34: Parts List For Carbon Resistors

    CDX-E400 Parts List for Carbon Resistors Value 1/4W Type Part No. 1/6W Type Part No. Value 1/4W Type Part No. 1/6W Type Part No. 1.0 Ω 3100 3100 7100 10 kΩ 7100 HJ35 HF85 HF45 HF45 ❊ 1.8 Ω 3180 7110 11 kΩ...
  • Page 35 CDX-E400...

Table of Contents