Summary of Contents for Quest Engineering 110 Dual
Page 1
Providing 110 pints of water removal per day at standard rating conditions (80ºF/60%RH), the Quest 110 Dual will effectively control humidity while using only 7.1 amps/115V. Features: •...
Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Quest 110 Dual indoor air quality system. READ AND SAVE THESE INSTRUCTIONS •...
1. Intended Application for Quest 110 Dual The Quest 110 Dual is intended for use in light commercial structures: however, the unit can be placed in almost any setting where dehumidification is desired. Use in highly corrosive applications and pool areas may void warranty.
3. Mount at least 4” above drain. (P-trap recommended - See pg. 8) 4. Do not install the Quest 110 Dual with the exhaust of the unit within 1’ of a wall or obstruction. Do not place the unit near open water.
4.3 Electrical Requirements The Quest 110 Dual plugs into a common grounded outlet on a 110-120 VAC 15-Amp circuit. While operating, it draws less than 7.2 amps @ 80°F, 60% RH and less than 6.8 amps @ 75°F, 50% RH. Use of a ground fault circuit interrupter (GFCI) protected circuit is recommended.
Improper installation of the drain hose may result in water leakage. If the Quest 110 Dual is located too far from the floor drain and the provided hose does not reach, you may use a 1/2” PVC rigid pipe to extend the drain. Rigid PVC tubing is readily available from your local hardware store. Be sure the extension is at a down-word slope to the drain.
Installation, Operation and Maintenance Instructions 5. Ducting 5.1 Duct Kit (P/N 4033039) A factory designed outlet duct kit can be purchased to accept 10” ducting to both outlets of the Quest 110 Dual. Contact your dealer or order online. 6. Operation 6.1 Humidity Control Adjustment...
7.1 Air Filter The Quest 110 Dual ships with a standard MERV 8 pleated fabric filter. This should be checked every six months. The pleated fabric filter can generally be vacuumed clean several times before needing replacement. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency and may cause the compressor to cycle on and off unnecessarily.
Quest 110 Dual Installation, Operation and Maintenance Instructions 8.2 Troubleshooting FOR THE USER: If the unit does not work properly, please check the following: — Is the unit unplugged? — Is power to outlet on? (check switch, if applicable) — Is circuit breaker tripped? —...
Page 11
Quest 110 Dual Installation, Operation and Maintenance Instructions Blower does not run with fan switch in either position. Compressor runs briefly but cycles on and off. Loose connection in blower circuit. Obstruction prevents impeller rotation. Defective blower. Defective blower switch.
(but all warranty periods will be extended by the period of time, if any, that the Quest 110 Dual Dehumidifier is out of service while awaiting covered warranty service).
Need help?
Do you have a question about the 110 Dual and is the answer not in the manual?