Disinfecting Unit; Replacement Of Wick; Removing Scale; Care And Maintenance - Aircare 831000 Use And Care Manual

Space saver evaporative humidifier
Table of Contents

Advertisement

Available languages

Available languages

REPLACEMENT OF WICK

CAUTION: Before changing wick, ensure unit
is turned OFF and unplugged.
NOTE: This unit uses model 1043 wick. Replace
the wick at the beginning of each season, and
more often in areas with hard water.
1) To replace wick, lift the retainer with wick out
of the unit. Lay the retainer on its back,
unsnap front grid from retainer frame. Extract
and discard old wick. Do not discard wick retainer.
2) Insert new wick into frame and reinstall retainer front grid

CARE AND MAINTENANCE

Cleaning your humidifier regularly helps eliminate odors and bacterial and
fungal growth. Ordinary household bleach is a good disinfectant and can be used to
wipe out the humidifier base and bottle/reservoir after cleaning .We recommend
cleaning your humidifier at least once every two weeks to maintain optimum
environmental conditions for your home. We also recommend using AIRCARE
®
Essick Air
Bacteriostat Treatment each time you refill your humidifier to
eliminate bacterial growth. Add bacteriostat according to the instructions on the
bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number1970.
1) Turn off unit completely and unplug from outlet.
2) Lift off the chassis.
3) Roll or carry the base to cleaning basin. Lift wick from the base allowing the water
to drain and remove float assembly from wick. Rinse wick under fresh water only.
Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to
drain.

REMOVING SCALE

4) Pour out any remaining water from the reservoir. Fill reservoir ½ full with water and
add 8 oz. (1 cup) of white vinegar. Let stand 20 minutes.
5) Dampen a soft cloth with undiluted white vinegar and wipe out reservoir to remove
scale. Rinse the water bottle and reservoir thoroughly with fresh water to remove
scale and cleaning solution before disinfecting.

DISINFECTING UNIT

6) Fill the reservoir ½ full with water and add 1 teaspoon of bleach. Let solution stay
for 20 minutes, then rinse with water until bleach smell is gone. Dry interior surfaces
with clean cloth. Wipe down the outside of the unit with a soft cloth dampened with
fresh water.
7) Refill unit and reassemble per ASSEMBLY instructions.

SUMMER STORAGE

1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wick and any water in the reservoir. Do not discard wick retainer.
Allow to dry thoroughly before storage. Do not store with water inside reservoir.
3) Do not store unit in an attic or other high-temperature area, as damage is probable.
4) Install new filter at beginning of season
7
.
®
or

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 831000 and is the answer not in the manual?

Questions and answers

Terry B Madison
January 19, 2025

The display shows current humidity level but flashes on an off while the unit seems to run normally

1 comments:
Dana Spriggs
January 20, 2025

I **** experiencing the same issue - also started on 1/19/25. This problem is not identified in your user's manual.

Steve Wagoner
January 22, 2025

Can I clean the wick on my 83100 with clorox bleach.

1 comments:
Mr. Anderson
February 10, 2025

No, the Aircare 831000 wick should not be cleaned with Clorox bleach. The manual specifies cleaning the wick under fresh water only, without using soap, detergent, or any other cleaners.

This answer is automatically generated

Richard
January 24, 2025

The unit flashes 20 but seems to work normally

Henry Huisman
April 15, 2025

my humidifier shuts down before room reaches preset level of humidity

1 comments:
Mr. Anderson
April 15, 2025

The Aircare 831000 humidifier shuts down when the set humidity level is reached. If it shuts down before reaching the preset level, it may be due to the built-in humidistat detecting that the humidity has already reached or exceeded the set point in its immediate area. Differences between actual room humidity and the unit’s sensor readings can cause this behavior.

This answer is automatically generated

Ross Sillery
April 3, 2025

can you operate the 831000 without a filter

User image 67edfe11cd898
2 comments:
Mr. Anderson
April 3, 2025

No, the Aircare 831000 cannot operate properly without a filter. It uses a wick filter (#1043) to humidify air as it passes through the saturated filter. Operating without a filter would prevent proper humidification and may damage the unit.

This answer is automatically generated

Ross Sillery
April 3, 2025

@Ross Sillery