Installation Instructions
Commissioning of HERON 2.2 after installation
Possible faults and remedy
Specifications
Warranty Conditions
Notice d'installation
Mise en service d'IBIS après l'installation
Défauts éventuels et solutions
Spécifications
Conditions de garantie
Einbauanleitung
Inbetriebnahme des IBIS nach dem Einbau
Mögliche Probleme und ihre Behebung
Spezifikationen
Garantiebedingungen
Instrucciones de Instalación
Puesta en Marcha del IBIS después de su instalación
Posibles fallos y soluciones
Especificaciones
Condiciones de la Garantía
HERON 2.2
AIRCONDITIONER
OWNER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERON 2.2 and is the answer not in the manual?

Questions and answers

Anthony Gledhill
January 22, 2025

Does the Heron 2.2 a/c have a reset button? Mine is neither heating or cooling.

IAN WHITER
February 2, 2025

what is the running amperage of the Heron 2.2 air conditioner

1 comments:
Mr. Anderson
February 10, 2025

The running amperage of the Aircommand Heron 2.2 air conditioner is 4.0A for cooling and 6.5A for heating.

This answer is automatically generated

William Abbott
February 24, 2025

During a prolonged use of my heron 2.2 aicon during a very hot day, water poured from underneath onto my tv…can you provide info to fix this..thanks Billy

1 comments:
Mr. Anderson
February 24, 2025

Water leakage from the Aircommand HERON 2.2 can be fixed by checking and correcting the drain installation. Ensure that the correct elbow is used at the air handler (A/H) and that it does not protrude above the grommet. The drain hose should have a continuous downward gradient and must not be kinked or blocked. Additionally, if condensate is dripping off the 3/8" flare nut on the A/H, wrap bituminous tape around the flare nut to insulate it.

This answer is automatically generated

Summary of Contents for Aircommand HERON 2.2

  • Page 1 HERON 2.2 AIRCONDITIONER OWNER’S MANUAL Pantone Cool Grey 9U Pantone 301 U Pantone DS196 - 4 U (Alternative) • Installation Instructions • Commissioning of HERON 2.2 after installation • Possible faults and remedy • Specifications • Warranty Conditions • Notice d’installation • Mise en service d’IBIS après l’installation • Défauts éventuels et solutions • Spécifications • Conditions de garantie • Einbauanleitung •...
  • Page 2 En el caso que se necesite hacer uso del servicio de garantía, el comprador debe ponerse en contacto con Aircommand Australia para la aprobación del servicio.
  • Page 3 CUSTOMER’S COPY Purchaser’s Name ............................................. Address ............................................................. P/Code .......... Phone ..........Email ............Purchase Date ................... Installed on ......................Model ......................Serial Number ......................Purchased From ..............................................Address ............................................................. P/Code .......... Phone ..........Email ............COPIE DU CLIENT Nom de l’acquéreur ............................................
  • Page 4 INSTALLATION INSTRUCTIONS FOR HERON 2.2 The Heron 2.2 is suitable for installation in most caravans & motorhomes. Installation in Commercial and Industrial vehicles and equipment should be referred to AIRCOMMAND AUST for assessment of suitability. The Heron System must be installed in accordance with national wiring regulations.
  • Page 5 INSTALLING THE CONDENSER SET Marking out the floor ■ Use the floor template as provided (or refer to fig. 3). Both, or either end of the con/set may be hard against a wall or panel, but the back of the unit must have sufficient clearance to allow easy access to the line valves (see fig.
  • Page 6 PIPE INSTALLATION & CONTROL WIRING Refrigeration Figure 6 pipes cross back The pipe work consists of a ” tube (liquid line), and a 2 return air of enclosure ” tube (return gas) running between the Con/set and filter assy. and come the A/H.
  • Page 7 Mark out the A/H cut out as per fig. 7. Ensure the choice of location satisfies the following: A. The Facia panel will be centrally located. B. The right hand edge of the cutout is a minimum of 50 mm from right hand end of the cupboard.
  • Page 8 Now Install the Air Handler ■ Insert the A/H into the front panel, and shift to the right as far as possible such that the right hand flange is fully over the front panel. Now insert a screw to hold the A/H in place while the copper tubes are manipulated to line up with the respective nipples.
  • Page 9 Note: The supply cord is designated Type F. If replacement is necessary it should be replaced by an Aircommand approved technician. Figure I: Prefered flaring Tips on Making Flare Joints tool ratchet/eccentric type ■...
  • Page 10 LEAK TESTING It is of the utmost importance that a leak check is made on the 4 flare nut connections. A leak, however small, will result in the aircon system losing capacity and endanger the compressor. 1. Use either soapy water, or a proprietary leak test solution. Paint on each flare nut (particularly the neck) and inspect carefully for any telltale bubbles.
  • Page 11 AVOID RESTARTING THE COMPRESSOR WITHIN 3 MINUTES OF TURNING OFF HEATING: (ref fig.16) NB. The unit will not heat if inside temp. is much above 28°C. 1. Turn fan speed selector to (Heating Speed) 2. Turn mode selector to (Heating) 3.
  • Page 13 TROUBLE SHOOTING Symptom Probable Cause Remedy Condenser set is noisy and Check that general pipework is Gently bend or pull away from vibrates not touching cabinet, lid, or panel etc chassis “Tipping” noise from Con/set Fan rotor touching inlet ring Ease motor retaining screws, and adjust “Tipping”...
  • Page 14 Please send to: AIRCOMMAND AUSTRALIA PTY LTD 954 Port Road, Albert Park South Australia 5014 AUSTRALIA Pantone Cool Grey 9U Pantone 301 U Pantone DS196 - 4 U (Alternative) Envoyer à: AIRCOMMAND AUSTRALIA PTY LTD 954 Port Road, Albert Park...
  • Page 15 MANUFACTURER’S COPY Purchaser’s Name ............................................. Address ............................................................. P/Code .......... Phone ..........Email ............Purchase Date ................... Installed on ......................Model ......................Serial Number ......................Purchased From ..............................................Address ............................................................. P/Code .......... Phone ..........Email ............COPIE DU FABRICANT Nom de l’acquéreur ............................................